• Title/Summary/Keyword: homogeneous field

Search Result 463, Processing Time 0.025 seconds

Three-Dimensional Field Equations, Equations of Motion, and Energy Functionals for Thick Shells of Revolution with Arbitrary Curvature and Variable Thickness (임의의 곡률과 변두께를 갖는 두꺼운 축대칭 회전 셸의 3차원적 장방정식, 운동 방정식, 에너지 범함수)

  • 강재훈;이은택;양근혁
    • Journal of KSNVE
    • /
    • v.11 no.1
    • /
    • pp.156-166
    • /
    • 2001
  • This work uses tensor calculus to derive a complete set of three-dimensional field equations well-suited for determining the behavior of thick shells of revolution having arbitrary curvature and variable thickness. The material is assumed to be homogeneous, isotropic and linearly elastic. The equations are expressed in terms of coordinates tangent and normal to the shell middle surface. The relationships are combined to yield equations of motion in terms of orthogonal displacement components taken in the meridional, normal and circumferential directions. Strain energy and kinetic energy functionals are also presented. The equations of motion and energy functionals may be used to determine the static or dynamic displacements and stresses in shells of revolution, including free and forced vibration and wave propagation.

  • PDF

Numerical Prediction of Flow Field in a Hard Disk Drive (하드 디스크 드라이브 내부의 유동장에 관한 수치적 연구)

  • Lee, Jae-Heon;Back, Y.R.;Kim, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.206-214
    • /
    • 1991
  • Flow field in a hard disk drive has been predicted numerically. Theoretical model was constructed based on a commercially available hard disk drive with 40 Mega byte capacity. Since the gap between disk tip and shroud is not homogeneous in real hard disk drive, three kinds of gap size have been tested as computational model. The discussion has been made on the circumferential velocity, radial velocity, and pressure fields. As a result, the average shear stress on the disk surface was reduced as the gap size decreased. This means that the shroud should be designed compactly to reduce power consumption of the spindle motor.

  • PDF

Characteristics of Amorphous Fe-based Thin Firms with Low Core Losses (저손실 Fe-계 비정질 박막의 자기적 특성)

  • 민복기;김현식;송재성;허정섭;오영우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.633-636
    • /
    • 1999
  • In this study, we have fabricated amorphous FeZrBAg thin films with low core losses by using DC magnetron sputtering method. After deposition, rotational field annealing (RFA) method was performed in the dc field of 1.5 kOe. The amorphous FeZrBAg thin films produced by annealing at 35$0^{\circ}C$ was founded to have high permeability of 8680 at 100 MHz, 0.2 mOe, low coercivity of 0.86 Oe high magnetization of 1.5 T and very low core loss of 1.3 W/cc at 1 MHz, 0.IT respectively. Excellent soft magnetic properties in a amorphous FeZrBAg thin films in the present study are presumably the homogeneous formation of very fine bcc $\alpha$-Fe crystalline with the 8.2 nm in an amorphous FeZrBAg thin film matrix.

  • PDF

Homogeneous Aligned Single Gap Transflective Display driven by Fring-field using a Liquid Crystal with Positive Dielectic Anisotropy (유전율 이방성이 양인액정을 이용한 Fringe-Field 구동형 수평배향된 단일갭 반투과형 디스플레이)

  • Lim, Young-Jin;Choi, Min-Oh;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.54-57
    • /
    • 2005
  • We have designed a single gap transflective liquid crystal display (LCD) driven by a fringe electric field, in which the +LC (${\Delta}{\varepsilon}$=7.4, rubbing angle= $80^{\circ}$) is homogeneously aligned in the initial state. This device is a problem that the voltage-dependent transmittance and reflectance curves do not match each other. Thus a dual driving circuit is required. This study shows that optimization of the rubbing angle in the transmissive and reflective regions solves this problem so that the transflective display with a single cell gap and single gamma curve for reflective and transmissive region is possible.

  • PDF

A Study on the Fabrication of Magnetorheometer (마그네토리오메타 제작에 관한 연구)

  • 김영민;신영재;이응숙;김동우;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.496-500
    • /
    • 2004
  • A new, commercially available polishing process called magnetorheological finishing is used to polish and figure precision optics. To understand and model this process correctly it is important to determine the mechanical properties of the fluid under the influence of the magnetic field. Magnetorheological (MR) fluids are commonly modeled as Bingham fluids, so one of the essential properties to measure is the yield stress. Since MR fluids are inherently anisotropic, the yield stress will depend on the mutual orientation of the magnetic field and the direction of deformation. The relative orientation of the field and deformation in polishing does not coincide with common rheological setups, so a new rheometer has been designed and tested. This new magnetorheometer design has been shown to give correct stresses during calibration experiments using Newtonian fluids with a known viscosity. The measured stress has also been shown to have a magnitude consistent with published finite element approximations for magnetic fluids. The design of the instrument was complicated because of the requirements imposed upon the magnetic field, and the difficulty in satisfying the no slip boundary condition. Our results show the importance of having a homogeneous field in the test region during measurements. The solutions to these problems and discussion of the measurements on nonmagnetic and magnetic fluids are given.

  • PDF

An algorithm to infer the central location of a solenoid coil for the mapping process based on harmonic analysis (조화해석 기반의 맵핑을 위한 솔레노이드 코일의 중심위치 추론 알고리즘)

  • Lee, Woo-Seung;Ahn, Min-Cheol;Hahn, Seung-Yong;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • Shimming, active and/or passive, is indispensable for most MR (magnetic resonance) magnets where homogeneous magnetic fields are required within target spaces. Generally, shimming consists of two steps, field mapping and correcting of fields, and they are recursively repeated until the target field homogeneity is reached. Thus, accuracy of the field mapping is crucial for fast and efficient shimming of MR magnets. For an accurate shimming, a "magnetic" center, which is a mathematical origin for harmonic analysis, must be carefully defined, Although the magnetic center is in general identical to the physical center of a magnet, it is not rare that both centers are different particularly in HTS (high temperature superconducting) magnets of which harmonic field errors, especially high orders, are significantly dependent on a location of the magnetic center. This paper presents a new algorithm, based on a field mapping theory with harmonic analysis, to define the best magnetic center of an MR magnet in terms of minimization of pre-shimming field errors. And the proposed algorithm is tested with simulation under gaussian noise environment.

Research of 6 MeV Electron Dose Distribution (6 MeV Electron Therapy에서의 Electron Dose Distribution에 관한 연구)

  • Je Jae-Yong;Park Chul-Woo;Jin Sung-Jin;Park Eun-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 2005
  • Purpose : Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribution in source surface distance(SSD)and source bolus distance(SBD)setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Materials and Methods : The electron dose distribution measures the diameter for 20 cm hemisphere paraffin phantom 2 made. It inserted the film between 2 paraffin phantom and it investigated it got radiation and dose distribution curve. Results : The 8% of isodose difference is with the surface distance(SSD)and source bolus distance(SBD)setup. The electon when the nipple exists inside the field, as nipple size it cuts the bolus and when it puts out and there is a possibility of getting the dose distribution which is homogeneous. When in the junction of electron and photon it uses the bolus it uses in the electron field whole, there is a possibility of getting the dose distribution which is homogeneous. Conclusion : The dose distribution decrease from the SBD setup. To reduce the influence of nipple, corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon. In the future becomes the research which sees an effective electron therapy.

  • PDF

A simulation study on the variation of virtual NMR signals by winding, bobbin, spacer error of HTS magnet

  • Kim, Junseong;Lee, Woo Seung;Kim, Jinsub;Song, Seunghyun;Nam, Seokho;Jeon, Haeryong;Baek, Geonwoo;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.21-24
    • /
    • 2016
  • Recently, production technique and property of the High-Temperature Superconductor (HTS) tape have been improved. Thus, the study on applying an HTS magnet to the high magnetic field application is rapidly increased. A Nuclear Magnetic Resonance (NMR) spectrometer requires high magnitude and homogeneous of central magnetic field. However, the HTS magnet has fabrication errors because shape of HTS is tape and HTS magnet is manufactured by winding HTS tape to the bobbin. The fabrication errors are winding error, bobbin diameter error, spacer thickness error and so on. The winding error occurs when HTS tape is departed from the arranged position on the bobbin. The bobbin diameter and spacer thickness error occur since the diameter of bobbin and spacer are inaccurate. These errors lead magnitude and homogeneity of central magnetic field to be different from its ideal design. The purpose of this paper is to investigate the effect of winding error, bobbin diameter error and spacer thickness error on the central field and field homogeneity of HTS magnet using the virtual NMR signals in MATLAB simulation.

Study on Retardation Value of Fringe-Field Driven Homogeneously Aligned Nematic Liquid Crystal Cell using Liquid Crystals with Positive Dielectric Anisotropy (유전율 이방성이 양인 액정을 이용한 Fringe-Field Driven 수평 배향셀의 위상지연값 연구)

  • 정송희;김향율;송성훈;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.305-310
    • /
    • 2004
  • We have studied the optimal phase retardation value of a homogeneously aligned liquid crystal (LC) driven by fringe-field when using the LC with positive dielectric anisotropy. In general, the transmittance of a homogeneous aligned LC cell under crossed polarizer is maximum when a twist angle of LC by in-plane rotation is 45$^{\circ}$ with polarizer and the cell retardation becomes λ/2. However, the device using the LC with positive dielectric anisotropy does not follow this since the degree of rotation of the LC is dependent on electrode position and in addition the LCs tilt up along the fringe-field. At the center of common and pixel electrode, the LC is most twisted around a middle position of a cell whereas at the edge position of pixel electrode, the LC is most twisted near bottom surface of a cell. Consequently, the optimal phase retardation of the device becomes much larger than λ/2 and the transmittance can be described using the combination of the in-plane switching and twisted nematic mode.

Test of magnetic turbulence anisotropy associated with magnetic dipolarizations

  • Lee, Ji-Hee;Lee, Dae-Young;Park, Mi-Young;Kim, Kyung-Chan;Kim, Hyun-Sook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • The anisotropic nature of the magnetic turbulence associated with magnetic dipolarizations in the Earth's plasma sheet is examined. Specifically we determine the power spectral indices for the perpendicular and parallel components of the fluctuating magnetic field with respect to the background magnetic field and compare them to determine possible anisotropic features. For this study, we identify a total of 47 dipolarization events from February 2008 using the magnetic field observations by the THEMIS A, D and E satellites when they are situated closely near the neutral sheet in the near-Earth tail. For the identified events, we estimate the spectral indices for the frequency range from 1.3 mHz to 42 mHz. The results show that for many events the spectral indices are larger for fluctuations in the ${\Psi}$ direction than for those in the other two directions, where the ${\Psi}$ direction is perpendicular to the background magnetic field line and to the azimuthal direction. This implies that the dipolarization-associated turbulence of the magnetic field is often anisotropic. We discuss how this result differs from what is expected from the theory of homogeneous, anisotropic, MHD turbulence.

  • PDF