• Title/Summary/Keyword: holographic

Search Result 818, Processing Time 0.031 seconds

Three-dimensional Binocular Holographic Display Using Liquid Crystal Shutter

  • Kim, Hyun-Eui;Kim, Hee-Seung;Jeong, Kyeong-Min;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.345-351
    • /
    • 2011
  • We present a novel approach to the holographic three-dimensional display using a liquid crystal shutter for binocular display applications. One of the difficult problems in implementing a binocular holographic three-dimensional display is the extremely narrow viewing angle. This problem is attributed to the spatial light modulator pixel number which restricts the maximum spatial bandwidth of the spatial light modulator. In our proposed method, a beam splitter and liquid crystal shutter are used to present two holograms of a three-dimensional scene to the corresponding eyes. The combination of holographic display and liquid crystal shutter can overcome the problem of the extremely narrow viewing angle, presenting threedimensional images to both eyes with correct accommodation depth cues.

Measurements of Three-Dimensional Droplet Velocities Using the Holographic System (홀로그래피를 이용한 분무 액적의 3차원 속도 측정)

  • Oh, Dai-Jin;Choo, Yeon-Jun;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.6 no.4
    • /
    • pp.31-38
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, the holographic panicle velocimetry system was used to measure the sizes and velocities of droplets formed by a commercial full cone spray nozzle. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The droplet velocities ranged from 10.3 to 13.3 m/s with average uncertainty of ${\pm}1.6m/s$, which is ${\pm}14%$ of the mean droplet velocity. Compared with relatively small uncertainties of velocity components in the normal direction to the optical axis, the uncertainty of the optical axis component is ${\pm}3.6m/s$. This is due to the long depth of field of droplet images in the optical axis, which is inherent feature of holographic system using forward-scattering object wave of particles.

  • PDF

Sampling theory and widening of the viewing area for holographic stereograms (홀로그래픽 스테레오그램에 관한 샘플링 이론과 관찰영역의 확대)

  • Kim, Eun-Seok;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.322-327
    • /
    • 1996
  • Unlike holograms of real objects, holographic stereograms(HS) are made using a relatively small number of synthesized 2D images. The influence of aliasing artifacts caused by insufficient or improper sampling is presented, and a new sampling theory is proposed, which is used to making holographic stereograms. Also, the optical system for extension of viewing distance and viewing zone is proposed. Results of this analysis can be applied to design normal holographic stereograms and computer based holographic stereograms.

  • PDF

Experimental Validation for the Development of Holographic Particle Velocimetry System for Spray Droplets (홀로그래피를 이용한 분무 액적 속도 측정시스템 개발을 위한 실험적 검증)

  • Gang, Bo-Seon;O, Dae-Jin;Chu, Yeon-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.539-546
    • /
    • 2002
  • The Holographic Particle Velocimetry system can be a promising optical tool leer the measurements of three dimensional particle velocities. In this research, validation experiments for the development of holographic particle velocimetry system for spray droplets were conducted with measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities obtained with holographic method are compared reasonably well with the known values within acceptable range of errors.

Full Color Holographic Optical Element Fabrication for Waveguide-type Head Mounted Display Using Photopolymer

  • Piao, Jing-Ai;Li, Gang;Piao, Mei-Lan;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.242-248
    • /
    • 2013
  • Full color holographic optical element fabrication using a photopolymer is proposed for a waveguide-type head mounted display. The fabricated full color holographic optical elements can be attached to the waveguide to replace the conventional couple-in and couple-out optics in the head mounted display. To implement the system, this study analyzed the optical characteristics of the photopolymer using three lasers (red, green and blue). Considering the color uniformity, a new laminated structure for a full color holographic optical element was also designed. The proposed system was confirmed experimentally.

Application of Holographic Interferometry and 2-D PIV for HSC Convective Flow Diagnostics (Hele-Shaw Cell 내부의 열유동 해석을 위한 홀로그래픽 간섭계와 2차원 PIV의 적용)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.682-687
    • /
    • 2003
  • The variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasisteady changes of temperature field, two different measurement methods of holographic interferometry; double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves can be eliminated effectively using digital image processing technique and the reconstruction images are clear, but transient flow structure cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

  • PDF

Concept Design of Servo System for the Holographic Memory of One Dimensional Spatial Light Modulator (1차원 광변조기의 홀로그래픽 메모리용 서보 시스템 설계)

  • Kim, Young-Joo;Chung, Suk-Ho;Yi, Jong-Su;Yun, Sang-Kyeong
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.214-218
    • /
    • 2006
  • The focus and tracking servo system has been designed and proposed for the holographic memory of one dimensional spatial light modulator(SLM). The general servo method of conventional ODD system was based and modified for new holographic memory. The pre-grooved disc pattern and special dichroic coating were also included for new design in this research and the final separated optics are expected to be applied to the future general holographic memory as well as the one dimensional SLM holographic memory.

  • PDF

Development of Holographic Particle Velocimetry System and Its Application to Spray Droplets (홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.17-28
    • /
    • 2005
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, diffused illumination holographic system to measure the sizes and 3D velocities of moving particles based on automatic image processing was developed. First of all basic optical systems for pulse laser recording, continuous laser reconstruction, and image acquisition, were constructed. To determine the position of particles in the optical axis, new three auto-focusing parameters(AEP), namely, Correlation Coefficient, Sharpness Index, and Depth Intensity were introduced and verified. The developed system was applied to spray droplets to validate the capability of the system. Three dimensional positions of particles viewed from two sides were decided using AFP and then 3D velocities of Particles were extracted by particle tracking algorithm. Comparison of measurement results of sizes and 3D velocities of particles with those obtained by laser instrument, PDPA, showed good consistency of the developed holographic system.

  • PDF

Modeling of the Inter-Page Interference on the Holographic Data Storage Systems (홀로그래픽 저장장치에서 인접 페이지 간 간섭 모델링)

  • Park, Dong-Hyuk;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.581-586
    • /
    • 2010
  • The holographic data storage system stores multiple data pages by multiplexing. But the inter-page interference(IPI) caused by multiplexing reduces the intensity of the hologram. The simulation of the holographic storage systems has to consider the IPI. Therefore, we introduce a channel modeling that takes care of inter-page interference in the holographic data storage system. We simulate the performance of PRML detection on the hologrpahic data storage system with IPI modeling.

Bit Error Reduction for Holographic Data Storage System Using Subclustering (서브클러스터링을 이용한 홀로그래픽 정보저장 시스템의 비트 에러 보정 기법)

  • Kim, Sang-Hoon;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part so fast data transfer rate and high storage capacity about 1Tb/cm3 can be realized. In this research, to correct errors of binary data stored in holographic data storage system, a new method for reduction errors is suggested. First, find cluster centers using subtractive clustering algorithm then reduce intensities of pixels around cluster centers. By using this error reduction method following results are obtained ; the effect of Inter Pixel Interference noise in the holographic data storage system is decreased and the intensity profile of data page becomes uniform therefore the better data storage system can be constructed.