• Title/Summary/Keyword: hollow-fiber

Search Result 631, Processing Time 0.028 seconds

A Study on the Collapse Characteristics of Al/CFRP Square Structural Member for Light Weight (경량화용 Al/CFRP 사각 구조부재의 압궤 특성에 관한 연구)

  • Hwang, Woo-Chae;Sim, Jae-Ki;Yang, In-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.219-224
    • /
    • 2011
  • Aluminum or CFRP is representative one of the lightweight materials. Collapse behavior of Al/CFRP square structural member was evaluated in this study based on the respective collapse behavior of aluminum and CFRP member. Al/CFRP square structural members were manufactured by wrapping CFRP prepreg sheets outside the aluminum hollow members in the autoclave. Because the CFRP is an anisotropic material with mechanical properties, The Al/CFRP square structural members stacked at different angles(${\pm}15^{\circ}$, ${\pm}45^{\circ}$, ${\pm}90^{\circ}$, $90^{\circ}/0^{\circ}$ and $0^{\circ}/90^{\circ}$ where the direction on $0^{\circ}$ coincides with the axis of the member) and interface numbers(2, 3, 4, 6 and 7). The axial impact collapse tests were carried out for each section members. Collapse mode and energy absorption characteristics of the each member were analyzed.

Cytotoxicity of Listeriolysin O Produced by Membrane-Encapsulated Bacillus subtilis on Leukemia Cells

  • Stachowiak, R.;Granicka, L.H.;Wisniewski, J.;Lyzniak, M.;Kawiak, J.;Bielecki, J.
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.11
    • /
    • pp.1193-1198
    • /
    • 2011
  • Encapsulation of biological material in the permiselective membrane allows to construct a system separating cells from their products, which may find biotechnological as well as biomedical applications in biological processes regulation. Application of a permiselective membrane allows avoiding an attack of the implanted microorganisms on the host. Our aim was to evaluate the performance of Bacillus subtilis encapsulated in an elaborate membrane system producing listeriolysin O, a cytolysin from Listeria monocytogenes, with chosen eukaryotic cells for future application in anticancer treatment. The system of encapsulating in membrane live Bacillus subtilis BR1-S secreting listeriolysin O was proven to exert the effective cytotoxic activity on eukaryotic cells. Interestingly, listeriolysin O showed selective cytotoxic activity on eukaryotic cells: more human leukemia Jurkat T cells were killed than human chronic lymphocytic B cells leukemia at similar conditions in vitro. This system of encapsulated B. subtilis, continuously releasing bacterial products, may affect selectively different types of cells and may have future application in local anticancer treatment.

Eccentric Axial Load Test for Concrete-Filled Tubular Columns Encased with Precast Concrete (프리캐스트 콘크리트에 의해 피복된 콘크리트충전 강관기둥의 편심압축실험)

  • Lee, Ho Jun;Park, Hong Gun;Kim, Sung Bae;Park, Sung Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • In this paper, concrete-filled steel tubular columns encased with precast reinforced concrete were studied. Four eccentrically loaded columns and a concentrically loaded column were tested to investigate the axial load-carrying capacity. The test parameters were the use of fiber reinforcement for cover concrete, eccentricity, column length, and lateral reinforcement. The maximum axial loads of the specimens agreed with the nominal strengths predicted by KBC 2009. However, in some specimens, the load carrying capacity quickly decreased after the peak strength due to spalling of the cover concrete.

Pretreatment of Acrylic Wastewater and Application of UF/RO Processes (Acrylic 폐수의 전처리 및 UF/RO공정의 적용)

  • 이광현
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.152-160
    • /
    • 2001
  • The pretreatment for COD removal of acrylic wastewater and separation characteristics of ultrafiltration hollow fiber type module and reverse osmosis spiral wound type module with the variation of applied pressure and temperature were discussed. Thc optimum washing time of membranes was decided with long team operation and the degree of fouling was discussed with operating time. Permeate flux was decreased rapidly at 14 hrs and that of reverse osmosis membrane was indicated similarly. CaO find sand filter for the first step, neutralization process with treated acrylic wastewater as the second step, UF/RO processes were used as final strep. It was shown treat COD and TDS were below allowable discharge value with the result.

  • PDF

The Effect of Gel Layer Formation on Fouling Characteristics in Ultrafiltration of Peach Juice (복숭아 주스의 한외여과시 겔층형성에 따른 막오염 특성)

  • 고은정;이주백;이준호;최용희
    • Food Science and Preservation
    • /
    • v.6 no.4
    • /
    • pp.424-428
    • /
    • 1999
  • The performance of a 30K polysulfone membrane for clarification of depectinized peach juice was studied Ultrafiltration of peach juice could minimize to loss of flavor and many compounds and was expected to effectively remove precipitation and suspended solid. The results showed that permeate flux increased with the increase of operating pressure and temperature. The permeate flux declined continuously as the process time increased. The values of soluble solid and titratable acidity of permeate were decreased or were at the same level, the turbidity was largely decreased. Total resistance decreased with lower temperature and lower pressure.

  • PDF

CFRP strengthening of steel beam curved in plan

  • Keykha, Amir Hamzeh
    • Steel and Composite Structures
    • /
    • v.41 no.5
    • /
    • pp.637-648
    • /
    • 2021
  • Nowadays, one of the practical, fast and easy ways to strengthen steel elements is the use of Carbon Fiber Reinforced Polymer (CFRP). Most previous research in the CFRP strengthening of steel members has carried out on straight steel members. The main difference between horizontal curved beams and straight beams under vertical load is the presence of torsional moment in the horizontal curved beams. In the other words, the horizontal curved beams are analyzed and designed for simultaneous internal forces included bending moment, torsional moment, and shear force. The horizontal curved steel beams are usually used in buildings, bridges, trusses, and others. This study explored the effect of the CFRP strengthening on the behavior of the horizontal curved square hollow section (SHS) steel beams. Four specimens were analyzed, one non-strengthened curved steel beam as a control column and three horizontal curved steel beams strengthened using CFRP sheets (under concentrated load and uniform distributed load). To analyze the horizontal curved steel beams, three dimensional (3D) modeling and nonlinear static analysis methods using ANSYS software were applied. The results indicated that application of CFRP sheets in some specific locations of the horizontal curved steel beams could increase the ultimate capacity of these beams, significantly. Also, the results indicated when the horizontal curved steel beams were under distributed load, the increase rate in the ultimate capacity was more than in the case when these beams were under concentrated load.

Developing Trend of Gas Separation Membrane for Dehumidification (제습용 기체분리막 개발동향)

  • Koh, Hyungchul;Lee, Choongsup;Ha, Seong Yong;Choi, Whee Moon;Rhim, Jiwon;Nam, Sangyong
    • Prospectives of Industrial Chemistry
    • /
    • v.14 no.3
    • /
    • pp.25-36
    • /
    • 2011
  • 압축공기 중의 수분은 공압설비의 모든 요소에 중대한 해를 입히며 밸브의 고착, 계기의 막힘 또는 공압기기의 오작동을 일으키며 생산하는 제품의 질에 있어서도 많은 해를 입혀서 제품의 질을 떨어뜨리는 역할을 하게 된다. 따라서 수분을 제거하는 방법이 필요하며 기존의 냉동식 및 흡착식을 대신하여 분리막 법이 적용될 수 있다. 현재 제습용 기체분리막 모듈은 적용이 시작된 단계에 있다. 제습용 기체분리막은 의료기기, 분석기기, Instrument air 장비에 응용이 진행되고 있다. 최근 들어 선진각국 뿐만 아니라 국내에서도 막소재 개발, 복합막 개발, 모듈 개발, 시스템 설계 및 제작 기술 개발이 진행되고 있다. 현재로서는 제습막공정에 적합한 막소재의 개발이 시급하지만 이후 적용확대를 위해서는 제습용 기체분리막의 신뢰성 향상을 위한 다각도의 노력이 필요하다.

A Study of Optimal Model for the Circuit Configuration of Korean Pulsatile Extracorporeal Life Support System (T-PLS) (한국형 박동식 생명구조장치(T-PLS) 순환회로를 위한 최적화 모델 연구)

  • Lim Choon Hak;Son Ho Sung;Lee Jung Joo;Hwang Znuke;Lee Hye Won;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.661-668
    • /
    • 2005
  • Background: We have hypothesized that, if a low resistant gravity-flow membrane oxygenator is used, then the twin blood sacs of TPLS can be located at downstream of the membrane oxyenator, which may double the pulse rate at a given pump rate and increase the pump output. The purpose of this study was to determine the optimal configuration for the ECLS circuits by using the concept of pulse energy and pump output. Material and Method: Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP) and pump output were collected at pump-setting rates of 30, 40, and 50 BPM. Result: At the given pump-setting rate, the pulse rate was doubled in the parallel group. Percent changes of mean arterial pressure to EEP were $13.0\pm1.7,\; 12.0\pm1.9\;and\;7.6\pm0.9\%$ in the parallel group, and $22.5\pm2.4,\; 23.2\pm1.9,\;and\;21.8\pm1.4\%$ in the serial group at 30, 40, and 50 BPM of pump-setting rates. Pump output was higher in the parallel circuit at 40 and 50 BPM of pump-setting rates $(3.1\pm0.2,\;3.7\pm0.2L/min\;vs.\;2.2\pm0.1\;and\;2.5\pm0.1L/min,\;respectively,\;p=0.01)$. Conclusion: Either parallel or serial circuit configuration of the ECLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration.

Separation and Recovery of $SF_6$ Gas from $N_2/SF_6$ Gas Mixtures by using a Polymer Hollow Fiber Membranes (고분자 중공사 분리막을 이용한 $N_2/SF_6$ 혼합가스로부터 $SF_6$의 분리 및 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • $SF_6$ (Sulfur hexafluoride) possesses high GWP (Global Warming Potential) as sepcified by the IPCC (Intergonvernmental Panel of Climate Change). Recently, the recovery-separtion of $SF_6$ research area, including permeation properties studies using various membrane's materials and the practical operation of recovery-separtion using membrane of waste $SF_6$ gas is in the initial state. The separation efficiency of a single $SF_6$ and waste $SF_6$ mixture was evaluated using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. According to the results of single gases permeation properties, PI membrane has the highest permselectivity of $N_2$ gas in $N_2/SF_6$ gas. Under the condition of P=0.5 MPa, the highest concentration of recovered $SF_6$ is 95.6 vol % in the separation experiment of $SF_6/N_2$ mixture gas by PC membrane. Under the operation pressure of P=0.3 MPa at a fixed retentate flow rate fixed of 150 cc/min, the maximum recovery efficiency of $SF_6$ is up to 97.8% by PSF membrane. From the results above, it is thought that the separation and recovery technique of $SF_6$ gas using membrane will be used as the representative eco-technology in the $SF_6$ gas treatment in the future.

Performance Analysis of CFRP Rear Spoiler according to Types of Inner Foam Core under High-speed Driving Condition (고속 주행 상황에서 CFRP 리어 스포일러의 내부 폼 코어 종류에 따른 성능 분석)

  • Sung-Eun Kim;Jun-Geol Ahn;Moon-Sung Kim;Seung-Ji Yang;Ki-Young Kim;Hyun-Ik Yang
    • Composites Research
    • /
    • v.37 no.2
    • /
    • pp.86-93
    • /
    • 2024
  • The inner foam structure plays an important role in the performance of the carbon-fiber-reinforced plastic (CFRP) rear spoiler used in automobiles. However, there is still a lack of studies for the CFRP-based rear spoiler according to the type of inner foam, especially under the high-speed driving condition. With this motivation, we numerically analyze the performance of the CFRP rear spoiler using various cases of the inner foam under the highspeed driving condition. Here, polymethacrylimide (PMI), polyvinyl chloride (PVC), and styrene acrylonitrile (SAN) resins are employed as the inner foams in this work. The performances are evaluated using the deformation aspects and vibration characteristics when the driving condition is a high-speed condition (200 km/h). Furthermore, to specifically verify the importance of the inner foam in the high-speed condition, we additionally investigate the performance of the CFRP rear spoiler without the inner foam structure (i.e., hollow type). As a result, it is confirmed that among the types of inner foams utilized in this work, the PMI and PVC inner foams have the best deformation aspect and vibration characteristic, respectively. Note that the hollow-type inner foam has inferior performances compared to other inner foams invoked in this study. Consequently, through this study, it can be confirmed that the inner foam structure can significantly improve the performance of the CFRP spoiler under high-speed driving condition (200 km/h), and also that the strengths of the CFRP spoiler can manifest differently depending on the types of inner foam core.