• Title/Summary/Keyword: hole injection

Search Result 577, Processing Time 0.026 seconds

Dependence of $O_2$ Plasma Treatment of ITO Electrode on Electrical and Optical Properties of Polymer Light Emitting Diodes (ITO 투명전극의 $O_2$ 플라즈마 처리가 고분자 유기발광다이오드의 전기.광학적 특성에 미치는 영향)

  • Gong, Su-Cheol;Back, In-Jea;Yoo, Jea-Huyk;Lim, Hun-Sung;Yang, Sin-Huyk;Shin, Sang-Bea;Shin, Ik-Seup;Chang, Gee-Keun;Chang, Ho-Jung
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.3
    • /
    • pp.93-97
    • /
    • 2006
  • Polymer light emitting diodes (PLEDs) are expected to be commercialized as next generation displays by advantages of the fast response time, low driving voltage and easy manufacturing process for large sized flexible display. Generally, the electrical and optical properties of PLEDs are affected by the surface conditions of transparent electrode. The PLED devices with ITO/PEDOT:PSS/PVK/PFO-poss/LiF/Al structures were prepared by using the spin coating method. For this, PEDOT:PSS(poly(3,4-ethylenedioxythiophene):poly(styrene sulfolnate)) Al 4083 and PVK(N-vinylcabozole) were used as hole injection and transport layers. The PFO-poss(poly(9,9-dioctylfluorene)) was used as the emitting layer. The dependence of $O_2$ plasma treatment of ITO electrode on the electrical and optical properties of PLEDs were investigated. The sheet resistances increased slightly with an improved surface roughness of ITO electrode as the RF power increased during $O_2$ plasma treatment. The PLED devices prepared on the ITO/Glass substrates, which were plasma-treated at 40 watt in RF power for 30 seconds under 40 mtorr $O_2$ pressure, showed the maximum external emission efficiency of 0.86 lm/W and the maximum luminance of $250\;cd/m^2$, respectively. The CIE color coordinates are ranged $X\;=\;0.13{\sim}0.18$ and $Y\;=\;0.10{\sim}0.16$, showing blue color. emission.

Emission Characteristics of Dual Emission Tandem OLED with Charge Generation Layer MoOx and Cathode Al Thickness (전하생성층 MoOx와 음극 Al의 두께에 따른 양면발광 적층 OLED의 발광 특성)

  • Kim, Ji-Hyun;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.316-321
    • /
    • 2016
  • To study emission characteristics for dual-emission tandem organic light emitting display (OLED), we fabricated blue fluorescent OLED according to thickness variation of $MoO_x$ as charge generation layer and Al as cathode. The bottom emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness showed threshold voltage of 9, 7, 9 V, maximum current emission efficiency of 19.32, 23.18, 15.44 cd/A and luminance of $1,000cd/m^2$ at applied voltage of 17.6, 13.2, 16.5 V, respectively. The top emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness indicated threshold voltage of 13, 10, 13 V, maximum current emission efficiency of 0.17, 0.23, 0.16 cd/A and luminance of $50cd/m^2$ at applied voltage of 22.6, 16.5, 20.1 V, respectively. In case of thicker or thinner than $MoO_x$ of 3 nm, the emission characteristics were decreased because of mismatching of electron and hole in emission layer. The bottom emission characteristics of OLED with Al 15, 20, 25 nm thickness showed threshold voltage of 8, 8, 7 V, maximum current emission efficiency of 18.42, 22.98, 23.18 cd/A and luminance of $1000cd/m^2$ at applied voltage of 16.2, 13.9, 13.2 V, respectively. The reduction of threshold voltage and increase of maximum current emission efficiency are caused by the increase of current injection according to increase of Al cathode thickness. The top emission characteristics of OLED with Al 15, 20, 25 nm thickness indicated threshold voltage of 7, 7, 8 V, maximum emission luminance of 371, 211, $170cd/m^2$, respectively. The top emission OLED of Al cathode with 15 nm thickness showed maximum luminance and it decreased at thickness of 20 nm. These phenomena are caused by the decrease of intensity of emitted light by reduction of optical transmittance according to increase of Al cathode thickness.

Thinning and drilling laser-assisted hatching in thawed embryo transfer: A randomized controlled trial

  • Le, Minh Tam;Nguyen, Thi Tam An;Nguyen, Thi Thai Thanh;Nguyen, Van Trung;Le, Dinh Duong;Nguyen, Vu Quoc Huy;Cao, Ngoc Thanh;Aints, Alar;Salumets, Andres
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.45 no.3
    • /
    • pp.129-134
    • /
    • 2018
  • Objective: In frozen and thawed embryos, the zona pellucida (ZP) can be damaged due to hardening. Laser-assisted hatching (LAH) of embryos can increase the pregnancy rate. This study compared thinning and drilling of the ZP before frozen embryo transfer (FET). Methods: Patients were randomly allocated into two groups for LAH using thinning or drilling on day 2 after thawing. Twenty-five percent of the ZP circumference and 50% of the ZP thickness was removed in the thinning group, and a hole $40{\mu}m$ in diameter was made in the drilling group. Results: A total of 171 in vitro fertilization/intracytoplasmic sperm injection FET cycles, including 85 cycles with drilling LAH and 86 cycles with thinning LAH, were carried out. The thinning group had a similar ${\beta}$-human chorionic gonadotropin-positive rate (38.4% vs. 29.4%), implantation rate (16.5% vs. 14.4%), clinical pregnancy rate (36.0% vs. 25.9%), miscarriage rate (5.8% vs. 2.4%), ongoing pregnancy rate (30.2% vs. 23.5%), and multiple pregnancy rate (7.0% vs. 10.6%) to the drilling LAH group. There were no significant differences in pregnancy outcomes between subgroups defined based on age (older or younger than 35 years) or ZP thickness (greater or less than $17{\mu}m$) according to the LAH method. Conclusion: The present study demonstrated that partial ZP thinning or drilling resulted in similar outcomes in implantation and pregnancy rates using thawed embryos, irrespective of women's age or ZP thickness.

Estimation of $CO_2$ saturation from time-lapse $CO_2$ well logging in an onshore aquifer, Nagaoka, Japan (일본 Nagaoka 육상 대수층에서 시간차 $CO_2$ 물리검층으로부터 $CO_2$ 포화도의 추정)

  • Xue, Ziqiu;Tanase, Daiji;Watanabe, Jiro
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.19-29
    • /
    • 2006
  • The first Japanese pilot-scale $CO_2$ sequestration project has been undertaken in an onshore saline aquifer, near Nagaoka in Niigata prefecture, and time-lapse well logs were carried out in observation wells to detect the arrival of injected $CO_2$ and to evaluate $CO_2$ saturation in the reservoir. $CO_2$ was injected into a thin permeable zone at the depth of 1110m at a rate of 20-40 tonnes per day. The total amount of injected $CO_2$ was 10400 tonnes, during the injection period from July 2003 to January 2005. The pilot-scale demonstration allowed an improved understanding of the $CO_2$ movement in a porous sandstone reservoir, by conducting time-lapse geophysical well logs at three observation wells. Comparison between neutron well logging before and after the insertion of fibreglass casing in observation well OB-2 showed good agreement within the target formation, and the higher concentration of shale volume in the reservoir results in a bigger difference between the two well logging results. $CO_2$ breakthrough was identified by induction, sonic, and neutron logs. By sonic logging, we confirmed P-wave velocity reduction that agreed fairly well with a laboratory measurement on drilled core samples from the Nagaoka site. We successfully matched the history changes of sonic P-wave velocity and estimated $CO_2$ saturation a(ter breakthrough in two observation wells out of three. The sonic-velocity history matching result suggested that the sweep efficiency was about 40%. Small effects of $CO_2$ saturation on resistivity resulted in small changes in induction logs when the reservoir was partially saturated. We also found that $CO_2$ saturation in the $CO_2$-bearing zone responded to suspension of $CO_2$ injection.

Nuclear Imaging Evaluation of Galactosylation of Chitosan (핵의학 영상을 이용한 chitosan의 galactosylation 효과에 대한 평가)

  • Jeong, Hwan-Jeong;Kim, Eun-Mi;Park, In-Kyu;Cho, Chong-Su;Kim, Chang-Guhn;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.253-258
    • /
    • 2004
  • Purpose: Chitosan has been studied as a non-viral gene delivery vector, drug delivery carrier, metal chelator, food additive, and radiopharmaceutical, among other things. Recently, galactose-graft chitosan was studied as a non-viral gene and drug delivery vector to target hepatocytes. The aim of this study was to investigate the usefulness of nuclear imaging for in vivo evaluation of targeting the hepatocyte by galactose grafting. Methods and Materials: Galactosyl methylated chitosan (GMC) was produced by methylation to lactobionic acid coupled chitosan. Cytotoxicity of $^{99m}Tc$-GMC was determined by MTT assay. Rabbits were injected via their auricular vein with $^{99m}Tc$-GMC and $^{99m}Tc$-methylated chitosan (MC), the latter of which does not contain a galactose group, and images were acquired with a gamma camera equipped with a parallel hole collimator. The composition of the galactose group in galactosylated chitosan (GC), as well as the tri-, di-, or mono-methylation of GMC, was confirmed by NMR spectroscopy. Results: The results of MTT assay indicated that $^{99m}Tc$-GMC was non-toxic. $^{99m}Tc$-GMC specifically accumulated in the liver within 10 minutes of injection and maintained high hepatic uptake. In contrast, $^{99m}Tc$-MC showed faint liver uptake. $^{99m}Tc$-GMC scintigraphy of rabbits showed that the galactose ligand principally targeted the liver while the chitosan functionalities led to excretion through the urinary system. Conclusion: Bioconjugation with a specific ligand endows some degree of targetability to an administered molecule or drug, as in the case of galactose for hepatocyte in vivo, and evaluating said targetabililty is a clear example of the great benefit proffered by nuclear imaging.

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Comparison Study of Lesion Localization in Patients with Primary and Secondary Hyperparathyroidism using Double-Phase Tc-99m Sestamibi Scintigraphy (일차성 및 이차성 부갑상선기능항진증 환자에서 Double-Phase Tc-99m Sestamibi 스캔에 의한 병변의 국소화에 관한 비교)

  • Jeon, Tae-Joo;Lee, Jong-Doo;Rhyu, Young-Hoon;Park, Jung-Soo;Jang, Hang-Seok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.368-380
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). Materials and Methods: We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/female=5/22, age: $49.1{\pm}10.8$). Results: Eighteen lesions of primary HPT consisted of 13 adenomas and S hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.8% (10/17), 83.3% (10/12), 83.3% (10/12), 75.9% (22/29), and 37.5% (15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75% (12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Conclusion: Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits routine use of it for this disease.

  • PDF