• Title/Summary/Keyword: hipO

Search Result 91, Processing Time 0.022 seconds

Plasma-Sprayed $Al_{2}O_{3}-SiO_{2}$ Multi-Oxide Films on Stainless Steel Substrate

  • Korobova, N.;Soh, Deawha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.116-119
    • /
    • 2000
  • The advantage of plasma-sprayed coating is their good resistance against thermal shock due to the porous state of the coated layer with a consequently low Youngs modules. However, the existence of many pores with a bimodal distribution and a laminar structure in the coating reduces coating strength and oxidation protection of the base metals. In order to counteract these problems, there have been many efforts to obtain dense coatings by spraying under low pressure or vacuum and by controlling particle size and morphology of the spraying materials. The aim of the present study is to survey the effects of the HIP treatment between 1100 and 130$0^{\circ}C$ on plasma-sprayed oxide coating of A1$_2$O$_3$, A1$_2$O$_3$-SiO$_2$ on the metal substrate (type C18N10T stainless steel). These effects were characterized by phase identification, Vickers hardness measurement, and tensile test before and after HIPing, These results show that high-pressure treatment has an advantage for improving adhesive strength and Vickers hardness of plasma- sprayed coatings.

  • PDF

Directional Effect of Applied Pressure during the Sintering on the Microstructures and Fracture Toughness of Heat-treated Silicon Nitride Ceramics (소결시의 가압방식이 열처리 후 질화규소의 미세조직과 파괴인성에 미치는 영향)

  • 이상훈;박희동;이재도
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.6
    • /
    • pp.653-658
    • /
    • 1995
  • Directional effect of applied pressure during sintering on the microstructure and fracture toughness of the heat-treated silicon nitride ceramics has been investigated. The specimens with a composition of 92Si3N4-8Y2O3(in wt%) were sintered at 172$0^{\circ}C$ by a hot press (HP ) and a hot isostatic press (HIP) and heat-treated for grain growth at 1800~20$0^{\circ}C$. The fracture toughness of the HP samples increased with the grain size while the fracture toughness of the HIP treated samples remained the same even though the grain growth occurred. This discrepancy was explained by a bimodal grain size distribution and large aspect ratio of the HPed samples and a monomodal grain size distributjion and samll aspect ratio of the HIP treated samples.

  • PDF

The Effect of Pressure on the Abnormal Grain Growth in Alumina (알루미나의 비정상 입자성장에 미치는 압력의 영향)

  • Park, Hoon;Park, Sang-Yeup
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.7
    • /
    • pp.617-624
    • /
    • 2000
  • Abnormal grain growth in alumina was investigated during sinter-HIP process for better understanding of pressure effect on microstructural development. Abnormal grain growth of monolithic alumina was observed near surface region rather than interior region of specimen. Finite element analysis was used to estimate the pressure distribution developed in the specimen. Pressure distribution analysis was in good agreement with grain size distributjion in the specimen. The results of finite element analysis provided that abnormal grain growth monolithic alumina was resulted from the inhomogeneous pressure distribution in the specimen. MgO addition in alumina was effective for the suppression of abnormal grain growth in alumina under inhomogeneous pressure distribution during sinter-HIP process.

  • PDF

Effects of Aqueous Extract of Schizandrae Fructus on Lead-Induced Change of Monoamine Neurotransmitters in Hippocampus

  • Zhao, Rong Jie;Zhao, Zheng Lin;Zhao, Xiu Feng;Zhao, Guang Wen;Li, Meng Quan;Wu, Yi Yan;Li, Jing Qiu;Guan, Li Xin;Kim, Sang-Chan
    • Herbal Formula Science
    • /
    • v.17 no.2
    • /
    • pp.143-150
    • /
    • 2009
  • The effects of aqueous extract of Schizandrae Fructus (AESC) on lead (Pb)-induced changes of monoamine neurotransmitters in the hippocampus (HIP) of adult rats were investigated. Male Sprague-Dawley rats were received intraperitoneal (i.p.) administration of Pb acetate (5 mg/kg/d) for 28 days and sacrificed 7 days after the last administration. Concentrations of norepinephrine (NE), dopamine (DA), serotonin (5-HT), 5-hydroxyindole acetic acid (5-HIAA) in HIP were measured by HPLC. There were significant decreases of NE, DA, 5-HT and 5-HIAA in Pb treated rats (P < 0.05), while pretreatment with AESC (100 mg/kg/d or 300 mg/kg/d, p.o., 2 h before Pb) greatly inhibited the decrease of monoamine transmitters, respectively (P < 0.05). Also, AESC (300 mg/kg/d) significantly increased the reduction of glutathione contents and superoxide dismutase activities in HIP induced by chronic Pb. These results suggest that AESC ameliorates Pb-induced depletion of monoamine neurotransmitters in HIP through its antioxidant activity.

  • PDF

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

Effect of Change of Grain-Boundary Phases on the Fracture Toughness of Silicon Nitride Ceramics (입계상 변화가 질화규소의 요업체의 파괴인성에 미치는 영향)

  • Lee, Sang-Hun;Park, Hui-Dong;Lee, Jae-Do;Kim, Do-Yeon
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.699-705
    • /
    • 1995
  • Effect of the grain boundary phases in Si$_3$N$_4$ ceramics on the fracture tonghness has been investigated. The Si$_3$N$_4$-Y$_2$O$_3$-SiO$_2$, (YS) and Si$_3$N$_4$-Y$_2$O$_3$-Al$_2$O$_3$(YA) systems were Can/HIP treated at 1750$^{\circ}C$ and then heat-treated at 1800∼2000$^{\circ}C$. The fracture toughness of the YA system, the grain boundary phase was only glass phase after heat-treatement, was increased. That of the YS system, however, the grain boundary phase was changed from crystalline and glass to glass phase after the heat -treatement above 1900$^{\circ}C$, was abruptly decreased. The reason of the sudden drop of the fracture toughness of the YS system was believed that the change of the grain boundary phases from crystalline and glass to glass phase effected un the fracture behavior.

  • PDF

PLASMA SPRAYED COATINGS of ALUMINA OXIDE and MULLITE

  • Korobova, N.;Soh, Deawha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05a
    • /
    • pp.93-95
    • /
    • 2004
  • The present report is the investigation of the effects of the HIP treatment on plasma-sprayed ceramic coating of $Al_2$O$_3$, $Al_2$O$_3$- SiO$_2$ on the metal substrate. These effects were characterized by phase identification, Vickers hardness measurement, and tensile test before and after HIPing.

  • PDF

Effect of SiC Particles Size on the Densification of $Al_2O_3-SiC$ Composite During Pressureless Sintering ($Al_2O_3-SiC$ 복합재료의 상압소결시 치밀화에 미치는 SiC 원료분말의 크기영향)

  • 채기웅
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.11
    • /
    • pp.1261-1265
    • /
    • 1999
  • Effect of SiC particle size of the densification of Al2O3-SiC composite during pressureless sintering was investigated. Two types of SiC powders having average particle size of 0.15${\mu}{\textrm}{m}$ and 3${\mu}{\textrm}{m}$ were used. Densification rate of the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles was slower than that of the specimen containg 3${\mu}{\textrm}{m}$ SiC particles. Although the relative density of the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles was below 90% of theoretical density after sintering at 155$0^{\circ}C$ the complete closure of open pores occurred. Therefore full densification could be obtained by subsequent HIP. On the other hand in the specimen containing 3${\mu}{\textrm}{m}$ SiC particles the complete closed pore was observed at 95% of theoretical density. Such a fast pore closure in the specimen containing 0.15${\mu}{\textrm}{m}$ SiC particles is likely to occur as a result of dense reaction layer formation on the specimen surface which is attributed to the high reactivity of small size particles with sintering atmosphere.

  • PDF

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

Relationship between Lower -Limb Joint Angle and Muscle Activity due to Saddle Height during Cycle Pedaling (사이클 페달링 시 안장높이에 따른 하지관절 각도와 근육활성화의 상관관계)

  • Seo, Jeong-Woo;Choi, Jin-Seung;Kang, Dong-Won;Bae, Jae-Hyuk;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study was to investigate the effects of different saddle heights on lower-limb joint angle and muscle activity. Six elite cyclists(age: $32.2{\pm}5.2years$, height: $171.0{\pm}3.5cm$, weight: $79.7{\pm}5.6kg$, cycle career: $13{\pm}6.2years$) participated in three min. submaximal(90 rpm) pedaling tests with the same load and cadence based on saddle heights where subject's saddle height was determined by his knee flexion angle when the pedal crank was at the 6 o'clock position. Joint angles(hip, knee, ankle joints) and the activity of lower limb muscles(biceps femoris(BF), vastus lateralis(VL), tibialis anterior(TA) and gastrocnemius medial(GM)) were compared by measuring 3D motion and electromyography(EMG) data. Results showed that there were significant differences in minimum hip & knee joint angle and range of motion of hip and knee joint between saddle heights. Onset timing and integrated EMG of only BF among 4 muscles were significantly different between saddle heights. Especially there was a negative relationship between minimum hip joint angle and onset timing of BF in most subject, which means that onset timing of BF became fast as the degree of bending of the hip joint became larger by saddle height. Optimal pedaling will be possible through increased amount of muscle activation due to the appropriate burst onset timing by proper pedaling posture with adjusted saddle height.