• 제목/요약/키워드: hip prosthesis

검색결과 49건 처리시간 0.053초

Micro Total Hip Replacement in Two Dogs with Legg-Calvé-Perthes Disease

  • Roh, Yoon-seok;Heo, Su-Young;Yoon, Jang-won;Park, Jiyoung;Jeong, Seong-Mok;Lee, Hae-beom
    • 한국임상수의학회지
    • /
    • 제34권6호
    • /
    • pp.454-458
    • /
    • 2017
  • A Maltese (case 1) and a Pomeranian (case 2) presented with acute right and left hind limb weight-bearing lameness. On physical examination, they exhibited severe pain and crepitus on the coxofemoral joint of affected hind limb. In addition, decreased thigh girth measurements were noted compared with the opposite leg. Radiological exam revealed necrotic areas in the femoral head of affected hind limb. These dogs were diagnosed with Legg-$Calv{\acute{e}}$-Perthes disease (LCPD). The dogs underwent micro total hip replacement (THR). After surgery, at 3 years (case 1) and 7 months (case 2), both dogs recovered normal activity. The thigh girth and lameness scores were apparently improved in the affected limbs of both dogs. No complications of prosthesis implants, such as loosening, were noted. The clinical outcomes of these cases indicate that dogs with LCPD can be successfully treated with micro THR and have a good prognosis immediately after surgery.

Comparison of radiographic and computed tomographic acetabular index in small-breed dogs: a preliminary study using Maltese and Shih Tzu

  • Kanthavichit, Kanokporn;Klaengkaew, Auraiwan;Thanaboonnipat, Chutimon;Darawiroj, Damri;Soontornvipart, Kumpanart;Choisunirachon, Nan
    • Journal of Veterinary Science
    • /
    • 제22권4호
    • /
    • pp.58.1-58.13
    • /
    • 2021
  • Background: The morphometry of the acetabulum is one source of information that assists in the clinical diagnosis of the hip and influences the proper selection of a prosthesis, reducing post-operative complications such as those seen in total hip replacement (THR). However, acetabular parameters in small-breed dogs are rarely reported. Objectives: To investigate acetabular parameters using radiography and computed tomography (CT) in small-breed dogs with Maltese and Shih Tzu dogs used as model breeds. Methods: Standard calibrated, extended hip radiographs and CT images were obtained. Subsequently, acetabular width (AW) in various directions was measured using radiography and CT, whereas acetabular depth (AD) was obtained by CT. Acetabular index (AI) is a ratio calculated from AD and AW. Results: The values of AW and AD were much higher in Shih Tzu than in Maltese dogs. Male Shih Tzus showed higher values of these parameters than females, while sex-based differences in most of the parameters could not be detected in Maltese. Body weight, but not age, influenced AWs and ADs. While AWs and ADs were influenced by several factors, AI was comparable among the assessed factors and between Maltese and Shih Tzu dogs (p = 0.172; 31.42 ± 1.35 and 32.60 ± 1.80, respectively). Also, AI did not vary with breed, sex, or body size. Conclusions: The obtained radiographic and CT acetabular parameters could be useful as guidelines for evaluating the acetabulum of small-breed dogs in clinical practice.

Tribology for All-Ceramic Joint Prostheses

  • Ikeuchi, K.;Kusaka, J.;Yoshida, H.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 2000년도 Proceedings of 2000 International Nano Crystals/Ceramics Forum and International Symposium on Intermaterials
    • /
    • pp.165-177
    • /
    • 2000
  • Ceramic on ceramic total hip prostheses are developed to apply to young patients because lifetime of polyethylene joint prostheses is limited by loosening due to biological response. As mating faces of all-ceramic joint must be highly conformed to reduce stress concentration, wear properties of flat surfaces are investigated in this study. Through wear tests at 2 MPa of contact pressure and 36 mm/s of sliding velocity, alumina and silicon carbide keep low wear rate, high hardness and smooth surface. Soft surface film was detected after the test in bovine serum. This suggests that boundary lubrication is effective to reduce wear in all-ceramic joint.

  • PDF

종양인공관절 주위 골절의 피질골 지주 중첩 동종골 이식술 유무에 따른 결과 비교 (Periprosthetic Fracture around Tumor Prosthesis, Comparison of Results with or without Cortical Strut Onlay Allograft)

  • 김용성;조완형;송원석;이규평;전대근
    • 대한정형외과학회지
    • /
    • 제56권1호
    • /
    • pp.42-50
    • /
    • 2021
  • 목적: 종양인공관절 주위 골절은 안정된 고정의 어려움과 골유합 후에도 골질 약화로 해리 및 재골절 위험이 많다. 피질골 지주 중첩 동종골 이식술을 종양인공관절 주위 골절에 적용하면 내고정도 쉽고, 골유합 기간도 단축되며, 합병증도 줄일 수 있을 것이라고 생각하였다. 본 연구는 종양인공관절 주위 골절 27예(30 골절)의 골절의 양상과 치료 후 재건 술식에 따른 생존율 및 합병증, 중첩 동종골 이식술 추가 여부에 따라 골유합 기간 및 기능적 결과가 차이가 있는지 분석하였다. 대상 및 방법: 골절 치료 시 판형 동종골 이식을 한 군 16예와 시행하지 않은 군 14예를 비교하였다. 분석항목은 종양인공관절 치환술부터 골절까지 기간, 골절의 양상, 골유합 기간 차이, 합병증, 및 기능적 결과를 기술하였다. 결과: 골절 양상은 unified classification system (UCS) B형이 21예(70.0%, 21/30)로 가장 많았으며 그 중 B1이 14예(46.7%, 14/30), B2가 1예(3.4%, 1/30), B3가 6예(20.0%, 6/30)였고 C형이 9예(30.0%, 9/30)였다. Kaplan-Meier 법에 의한 30 재건 부위의 5년, 10년 생존율은 각각 84.5%±4.18%, 42.2%±7.83%였다. 전체 30예의 골유합 기간은 평균 5.1개월(범위, 2.0-11.2개월)이었다. 동종골 이식군은 평균 3.5개월(범위, 2.0-6.26개월)로 고식적 고정군의 평균 7.2개월(범위, 4.0-11.2개월)보다 짧았다(p<0.0001). 최종 기능평가상 동종골 이식군은 평균 26.1점으로 고식적 고정군의 평균 20.9점보다 높았다(p<0.0001). 합병증은 4예로 모두 동종골을 사용하지 않은 군에서 있었다. 결론: 종양인공관절 주위 골절은 드물고 골유합도 비교적 잘 이루어지나 유합 후 합병증 최소화가 중요하다. 판형 중첩 동종골 이식술은 골유합 기간을 단축, 골질 증가, 해리위험성 감소 효과가 있으며 종양인공관절 주위 골절에 유용한 방법이다.

하지 분절절제 및 회전재접합술자의 의지 보행훈련 증례연구 (A Case Study of Prosthetic Ambulation Training for Rotation-Plasty Client)

  • 이정원;정낙수
    • 한국전문물리치료학회지
    • /
    • 제3권1호
    • /
    • pp.65-72
    • /
    • 1996
  • The purpose of this study was to introduce rotation-plasty procedure and prosthetic ambulation training. The recent development of chemotherapy and diagnostic facility have permitted the orthopaedic surgeons to try limb saving procedures rather than amputations for the treatment of the malignant bone tumors. If the tumors around the knee joint were treated by mid-thigh amputation or hip disarticulation, it would impose the client with a great handicap for rehabilitation. Rotation-plasty procedure was first done by Borggreve, in 1930 for the congenital short femur. Recently this procedure was used a malignant bone tumor at the distal femur by Kotz and Salzer in 1982. In spite of its cosmetic problem of the distal stump, this procedure has the great functional advantage of converting the above-knee amputation to the below-knee amputation. The inverted foot was also good to control the prosthesis as a below-knee stump and heel functioned as a patella to support the body weight. This 15 years old girl case was had rotation-plasty due to osteosarcoma of the distal femur with 3rd postoperative chemotherapy, and admitted to Yonsei rehabilitation hospital for prosthetic ambulation training. Then, the case had excellent functional results of prosthetic ambulation training with rotaion-plasty after 3 months.

  • PDF

컴퓨터단층촬영검사에서 고관절 삽입물에 의한 영상평가 (Image Evaluation by Metallic Hip Prosthesis in Computed Tomography Examination)

  • 민병인;임인철
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.281-288
    • /
    • 2022
  • 본 연구에서는 고관절에 금속삽입물(Metal implant)이 삽입되어 있는 환자를 대상으로 일반적인 CT검사(Before MAR) 영상과 MAR을 사용하여 얻어진(After MAR) 영상을 4개의 알고리즘(Soft, Standard, Detail, Bone)에 적용하여 Noise, SNR, CNR을 비교 분석하여 정량적 평가로 최적의 알고리즘을 알아보고자 하였다. 분석방법으로는 4개의 알고리즘으로 재구성한 영상에 이미지 분석과 영역 및 픽셀값을 계산할 수 있는 Image J 프로그램을 사용하였다. Noise, SNR, CNR을 구하기 위해 측정부위를 영상에서 금속삽입물이 가장 인접해 있는 Bone(궁둥뼈, ischium)을 지정하여 HU mean값과 HU SD값을 구하고 배경잡음(Background)은 주위 근육으로 하였다. 관심영역(region of interest, ROI)은 뼈의 크기를 감안하여 동일하게 15×15 mm로 지정하였으며 SNR과 CNR의 값은 주어진 식에 의거하여 산출하였다. 결과적으로 노이즈는 After MAR, Soft 알고리즘에서 노이즈가 가장 낮게 나타났으며, SNR, CNR은 Before MAR, Soft 알고리즘이 가장 높게 나타났다. 따라서 Soft 알고리즘이 고관절 금속삽입술 CT에 가장 적절한 알고리즘으로 판단된다.

정형외과 영역에서의 삼차원 프린팅의 응용 (Three-Dimensional Printing Technology in Orthopedic Surgery)

  • 최승원;박경순;윤택림
    • 대한정형외과학회지
    • /
    • 제56권2호
    • /
    • pp.103-116
    • /
    • 2021
  • 삼차원(three-dimensional, 3D) 프린팅의 사용은 점차 보편화되고 있으며 정형외과 영역에서도 그 활용이 늘어나고 있다. 현재 정형외과에서 3D 프린팅 기술을 사용하는 방법은 크게 네 가지로 첫째, 3D 프린팅 모델을 이용한 수술 계획 수립 및 수술 시뮬레이션, 둘째, 환자 맞춤형 수술 기구, 셋째, 3D 적층 기법을 이용한 인공 삽입물의 생산, 넷째, 3D 프린팅으로 제작된 환자 맞춤형 삽입물이다. 3D 프린팅 기술을 사용할 수 있는 정형외과의 영역은 견관절, 척추, 고관절 및 골반, 슬관절, 족관절, 종양 분야 등으로, 각각의 영역마다 다루는 질환 및 특성이 다르기 때문에 3D 프린팅 기술을 사용하는 방법 역시 각각의 영역에 따라 약간의 차이가 있다. 하지만 모든 영역에서 3D 프린팅 기술을 이용하는 것은 수술의 효율을 높여 주고, 수술 시간을 단축시키며 수술 중 방사선 노출을 줄여 준다. 3D 프린팅 기술은 특히 복잡하고 어려운 질환이나 골절 환자의 치료에 큰 도움을 줄 수 있다. 따라서 정형외과 의사는 이러한 3D 프린팅 기술의 장점을 이해하고 임상에 최대한 적용하여 효율적인 환자의 치료가 이루어질 수 있도록 해야 한다.

인공발목관절의 표면 마모 특성 (Surface Tribology of Total Ankle Joint Replacement)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

대퇴골 전치환술 받은 악성 골종양 환자의 생존인자와 합병증 (Factors for Survival and Complications of Malignant Bone Tumor Patients with a Total Femoral Replacement)

  • 조완형;전대근;송원석;박환성;남희승;김경훈
    • 대한정형외과학회지
    • /
    • 제55권3호
    • /
    • pp.244-252
    • /
    • 2020
  • 목적: 대퇴골 전치환술은 사지재건술의 극단적 술식 중 하나이며 증례가 드물어 이에 대한 연구는 주로 술식 후의 합병증에 대한 분석이며 본 술식의 적응증에 대한 분석은 미미하다. 저자들은 대퇴골 전치환술 36예의 1) 종양적 문제로 치환술을 받은 환자의 생존에 관련된 예후인자, 2) 치환물 및 하지의 생존율, 3) 치환물을 3년 이상 추시한 예의 합병증, 최종 하지 상태 및 기능적 결과를 알아보고자 하였다. 대상 및 방법: 대퇴골 전치환술을 받은 이유에 따라 원발성 종양에 의한 경우(15예, 1군), 오인 수술 및 국소재발로 인한 경우(16예, 2군), 재건물 실패로 인한 경우(5예, 3군)의 세 군으로 분류하였다. 환자 생존인자 분석 항목은 나이, 성별, 전치환술 원인, 항암요법 전후 종양 부피 변화, 절제연, 국소재발이었다. 결과: 전체 36예의 5년 환자 생존율은 31.5%±16.2%였다. 종양과 관련된 적응증으로 치환술을 받은 31예의 5년 생존율은 21.1%±15.6%였다. 항암요법 전후 종양의 크기가 같거나 감소한 10예의 5년 생존율은 50.0%±31.0%로 크기가 증가한 13예의 0.0%±0.0%보다 유의하게 높았다(p=0.02). 광범위 절제연을 얻은 12예의 5년 생존율은 41.7%±27.9%로 변연부 절제연의 0.0%±0.0% 보다 유의하게 높았다(p=0.03). 성별, 나이, 대퇴골 전치환술을 시행받은 원인, 치환술 후 국소 재발여부와 생존율과의 유의한 차이는 없었다. 치환물 36예에서 5년 생존율은 16.6%±18.2%였다. 하지의 10년 생존율은 85.9%±14.1%였다. 최종 추시상 종양인 공관절을 유지한 것이 12예, 회전성형술은 2예, 슬관절 상부 절단술 1예, 관절고정술 1예였다. 대퇴골 전치환술 후 3년 이상 추시가 가능했던 16예 중 수술이 필요했던 주 합병증이 14예, 보존적 치료만 했던 저등급 감염이 2예였다. 수술한 환자 14예 중 감염이 10예(71.4%)예, 국소재발이 2예, 고관절 탈구, bushing 파손, 대퇴동맥 폐색이 각각 1예였다. 결론: 종양과 관련된 적응증으로 대퇴골 전치환술을 시행한 환자 중 항암요법 후 종양의 크기가 커지거나 절제연이 불량한 경우, 환자가 조기에 사망하는 경우가 많았다. 따라서 전치환술의 시행에 신중해야 할 것으로 생각된다. 장기 생존 환자에서도 감염률이 높고 기능적 결과도 만족스럽지 않으나 현재 적응증을 고려했을 때 대퇴골 전치환술은 사지보존을 위한 최선의 방법으로 보인다.