내저온열화 특성을 갖는 지르코니아/알루미나 복합세라믹의 마멸평가

  • Kim H.;Lee KY;Kim DJ;Lee MH;Seo WS
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear. Alumina and zirconia (3Y-TZP) are using in clinical application worldwide and there are many good test reports. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite having low temperature degradation-free character and high fracture tough . was developed and it leads the lower wear 3f polyethylene than alumina and zirconia. In the present study, in order to optimise the microstructure of low temperature degradation (LTD)-free zirconia/alumina composite for the best wear resistance of polyethylene, various compositions of (LTD)-free zirconia/alumina composites were fabricated, and the sliding wear of UHMWPE against these novel composites were examined and compared with that against alumina and zirconia ceramics used for total hip joint heads.

  • PDF

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.4
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

A Case of Atypical Bone Growth after Femur Neck Fracture in the Paraplegic Patient with Trochanteric Sore (대전자부 압박궤양을 가지고 있는 하지마비 환자에서 대퇴골 골절부위에 발생한 비정상적 골증식의 치험례)

  • Yang, Jeong Yeol;Cheon, Ji Seon
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.92-95
    • /
    • 2008
  • Purpose: Heterotopic ossification in pressure sore patients is reported to rarely develop, but once it occurs, it frequently causes joint stiffness and mobilization restriction. The aim of this article is to report our experience of atypical bone growing at femur neck fracture site with chronic, extensive pressure sore in patient with paraplegia secondary to spinal injury. Methods: A 28-year-old male patient presented with atypical bone growth at femur neck fracture site with pressure sore. He had undergone atypical growth bone removal and separation of united iliac bone and femur, and then pressure sore was covered by advanced rotation flap. Results: The patient mobilized hip joint and rode in a wheelchair. Complications such as dehiscence, infection, hematoma and flap necrosis did not occur. Conclusion: We experienced successful correction of atypical bone growth removal and recovery of pressure sore. We report our experience of atypical bone growth of fracture site and the related literature was reviewed.

Spontaneous Femoral Capital Physeal Fracture with Proximal Tibial Epiphyseal Dysplasia in a Cat

  • Yoo, Saejong;Kim, Dae-Hyun;Lee, Yunsub;Yeo, Seungyeob;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.36 no.2
    • /
    • pp.112-115
    • /
    • 2019
  • An 11-month-old, 5.6 kg, grade 4 on a 5-point scale body condition score, castrated male Korean short hair cat was presented with right hindlimb lameness for 3 days without trauma. On physical examination, severe pain with crepitation was elicited at the hip region but not at the stifle. Radiographic examination and computed tomography revealed a Salter-Harris type 1 fracture of the femoral capital physis and dysplasia of the proximal tibial epiphysis. Spontaneous femoral capital physeal fracture was suspected and femoral head and neck osteotomy was performed. Treatment for proximal tibial dysplasia was not performed. On histopathologic examination of femoral head, a cluster of chondrocytes in a proliferative zone at the epiphyseal plate was observed. Therefore, spontaneous femoral capital physeal fracture was diagnosed. The patient recovered his gait, and no related clinical signs were observed during 6 months of follow-up.

Mechanical Response of Changes in Design of Compression Hip Screws with Biomechanical Analysis (생체 역학적 분석에 의한 Compression Hip Screw의 디자인 요소에 대한 평가)

  • 문수정;이희성;권순영;이성재;안세영;이훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1172-1175
    • /
    • 2004
  • At present, CHS(Compression Hip Screw) is one of the best prosthesis for the intertrochanteric fracture. There is nothing to evaluate the CHS itself with the finite element analysis and mechanical tests. They have same ways of the experimental test of the ASTM standards. The purpose of this study is to evaluate the existing CHS and the new CHS which have transformational design factors with finite element analysis and mechanical tests. The mechanical tests are divided into compression tests and fatigue test for evaluating the failure load, strength and fatigue life. This finite element method is same as the experimental test of the ASTM standards. Under 300N of compression load at the lag screw head. There are less differences between Group (5H, basic type) and Group which has 8 screw holes. However, there are lots of big differences between Group and Group which is reinforced about thickness of the neck range. Moreover, the comparison of Group and Group shows similar tendency of the comparison of Group and Group . The Group is reinforced the neck range from Group. After the experimental tests and the finite element analysis, the most effective design factor of the compression hip screws is the reinforcement of the thickness, even though, there are lots of design factors. Moreover, to unite the lag screw with the plate and to analyze by static analysis, the result of this method can be used with experimental test or instead of it.

  • PDF

An Analysis on the Changes of Knees and Hip Joint Surface according to Elderly Women's Movements (노년 여성의 동작에 따른 무릎 및 고관절 주변 체표 길이 변화 분석)

  • Jang, Ji Hyeon;Jung, Hee Kyeong;Park, Jung Hyun;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.222-232
    • /
    • 2020
  • This study analyzes changes in the knees, hips, and hip joint length according to the different angles of bending knees by 45°, 90°, and 135° respectively for knees, hips, and the hip joint that have high fracture rates when falling down. The research subjects were 10 elderly women in their 60s (or older) that obtain data collected through direct measurement. For analysis, the study drew a diagram of elongation and shrinkage based on changes and change rate from a straight posture (0°) and conducted a statistical analysis on differences of body surface length by zone according to movements. The more the knees were bent, the vertical surface length in front of the knees, the horizontal surface length above the knee line, the horizontal body surface length below the knee lines on the back, and the vertical surface lengths between front side lines and the side lines increased; however, the vertical surface length on the back decreased. For the hip joint, the difference in the vertical surface length was more distinctive when compared to the horizontal. Finally, the horizontal surface length increased below the hips and the vertical surface length increased in most areas except the sidelines and the front. The result of the change in body surface length according to the movements of this study can be utilized in the development of the motion-variable protector.

A Clinical Analysis of Femur Neck Fracture in Elderly Patients (노년층에서 대퇴경부 골절의 치료)

  • Ihin, Joo-Choul;Ahn, Myun-Whan;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.11-22
    • /
    • 1985
  • Femur neck fracture is well known as one of the major death cause after trauma in elderly patients, and unsolved fracture due to its frequent association with complications such as avascular necrosis and nonunion. Through meticulous evaluation of the patient, hip and surgeon's experiences, reduction of mortality and morbidity as well as rapid recovery of the patient to the preinjury social and ambulatory status without local complications and revision after treatment is urgently needed. Many factors about this fracture In itself were noted, but we have analyzed 18 femur neck fractures of the patients older than 50 years preliminarily according to age, fracture pattern, osteoporosis, etiology and method of treatment with its delay in association with major complications especially avascular necrosis and nonunion. The results are as follows; 1. Of these 18 fractures, 11 were in females, 8 were caused by minor trauma such as slip-down accident and 4 were associated with definite osteoporosis according to the Sing's classification. 2. Fracture pattern of these 18 are undisplaced in 4, displaced subcapital in 11, displaced transcervical in 3. 11 fractures in the patients older than 60 year are composed of 3 undisplaced or impacted fractures and 8 displaced subcapital fractures. 3. These 18 fractures were treated by closed reduction and Internal fixation with multiple pins in 13, and hemiarthroplasty in 4, but one was not treated to die after discharge from hospital. 4. 4 undisplaced or impacted fractures and 3 displaced transcervical fractures were not associated with any complications such as avascular necrosis or nonunion. But 4 of 6 displaced subcapital fractures were complicated by avascular necrosis, 3 of which were reduced in the varus position within 1 week, and the other was reduced in the good position on 1 week after trauma. There was no complication in 2 displaced subcapital fractures reduced in valgus position within 3 days after trauma. According to the above results, the prognosis of the femur neck fracture is dependent upon the fracture pattern and delay in its treatment. So it is inevitable to reduce the fracture in anatomical or valgus position as early as possible. But the arthroplasty may be needed in displaced subcapital fractures delayed for several days, with its reluction in extreme varus position or impossible and with pre-existing disease in the same hip Joint (total hip replacement).

  • PDF

Learning Curve of the Direct Anterior Approach for Hip Arthroplasty (직접전방 접근법을 통한 인공 고관절 치환술의 학습곡선)

  • Ham, Dong Hun;Chung, Woo Chull;Choi, Byeong Yeol;Choi, Jong Eun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.143-153
    • /
    • 2020
  • Purpose: To evaluate the timing of the improvement in surgical skills of the direct anterior approach for hip arthroplasty through an analysis of the clinical features and learning curve in 58 cases. Materials and Methods: From November 2016 to November 2018, 58 patients, who were divided into an early half and late half, and underwent hip arthroplasty by the direct anterior approach, were enrolled in this retrospective study. The operation time and complications (fracture, lateral femoral cutaneous nerve injury, heterotopic ossification, infection, and dislocation) were assessed using a chi-square test, paired t-test, and cumulative sum (CUSUM) test. Results: The mean operation times in total hip arthroplasty (26 cases) and bipolar hemi-arthroplasty were 132.1 minutes and 79.7 minutes, respectively, demonstrating a significant difference between the two groups. CUSUM analysis based on the results revealed breakthrough points of the operation time, decreasing to less than the mean operation time because of the 16th case in total hip arthroplasty and 14th case in bipolar hemiarthroplasty. Complications were encountered in the early phase and late phase: five cases of fractures in the early phase, no case in the late phase; eight and two cases of lateral femoral cutaneous nerve injury, respectively; three and two cases of heterotopic ossification, respectively; and one case of dislocation, one case of infection and three cases of others in the early phase. The CUSUM chart for the fracture rate during operation in the early phase revealed the following: five cases fracture (17.2%) in the early phase and no case in the late phase (0%). This highlights the learning curve and the need for monitoring the inadequacy of operation based on the complications. Conclusion: Hip arthroplasty performed by the direct anterior approach based on an anatomical understanding makes it difficult to observe the surgical field and requires a learning curve of at least 30 cases.

The Problem-Solving Approach for Improving Walking Ability in Patient with Total Hip Replacement: Applied ICF Tool for Case Study (고관절 인공관절 치환술 환자의 보행능력 증진을 위한 문제해결 접근: ICF Tool을 적용한 단일사례연구)

  • Song, Hyun-seung;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.63-71
    • /
    • 2015
  • Background: The purpose of the study, using the ICF Tool in the process of rehabilitation of artificial joint replacement surgery of the hip joint, goal setting and understanding of the problem, through the process of creating intervention strategies, useful clinical practical course for rehabilitation I try to present the data. Methods: Fracture was the left total hip replacement (THR) surgery due to women of 76 years old. I proceed in order screening, evaluation, diagnosis, prognosis, treatment planning and intervention, re-screening. Needs of the patient was walking short distances for using the toilet. In order to improve was carried out arbitration, after you have created a list of issues that limit the ability to walk short distances. Results: It was revealed improved results in self-paced walk test (SPWT) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was used to examine whether the goals. In addition, MMT VAS, DGI, and TUG is a detailed goal was improved. Conclusions: It can be shown objectively the results of interventions performed for the purpose of solving the problem which is grasped through clinical Practical course for short-range walking ability enhance patient THR. I considered practical clinical course using the ICF Tool would be useful.

  • PDF

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.