• Title/Summary/Keyword: hip dysplasia

Search Result 38, Processing Time 0.028 seconds

A Study on a Mask R-CNN-Based Diagnostic System Measuring DDH Angles on Ultrasound Scans (다중 트레이닝 기법을 이용한 MASK R-CNN의 초음파 DDH 각도 측정 진단 시스템 연구)

  • Hwang, Seok-Min;Lee, Si-Wook;Lee, Jong-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.183-194
    • /
    • 2020
  • Recently, the number of hip dysplasia (DDH) that occurs during infant and child growth has been increasing. DDH should be detected and treated as early as possible because it hinders infant growth and causes many other side effects In this study, two modelling techniques were used for multiple training techniques. Based on the results after the first transformation, the training was designed to be possible even with a small amount of data. The vertical flip, rotation, width and height shift functions were used to improve the efficiency of the model. Adam optimization was applied for parameter learning with the learning parameter initially set at 2.0 x 10e-4. Training was stopped when the validation loss was at the minimum. respectively A novel image overlay system using 3D laser scanner and a non-rigid registration method is implemented and its accuracy is evaluated. By using the proposed system, we successfully related the preoperative images with an open organ in the operating room

Biomechanical Analysis of the Shelf Operation for Dysplastic Hip Joint by Finite Element Analysis (유한요소해석을 이용한 이형성 고관절의 선반형성술에 대한 생체역학 해석)

  • Park W.M.;Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.519-520
    • /
    • 2006
  • The aim of this study was biomechanical analysis of shelf operation in patients with dysplastic hip joint by finite element contact analysis. Two dimensional CT images were used to construct the finite element models to analyze the contact pressure, and the 3D expansion of the Ninomiya's method was used in the calculation of the resultant force in the hip joint. The surgery recovered the center-edge angles to the normal anatomical range and increased the contact areas in two patients. The maximum contact pressures and von-mises stresses were decreased. The present study provides the biomechanical guideline of optimal surgical parameters to maximize the surgical efficiency and the clinical outcomes in dysplastic hip joint using the shelf operation.

  • PDF

Spontaneous Femoral Capital Physeal Fracture with Proximal Tibial Epiphyseal Dysplasia in a Cat

  • Yoo, Saejong;Kim, Dae-Hyun;Lee, Yunsub;Yeo, Seungyeob;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.36 no.2
    • /
    • pp.112-115
    • /
    • 2019
  • An 11-month-old, 5.6 kg, grade 4 on a 5-point scale body condition score, castrated male Korean short hair cat was presented with right hindlimb lameness for 3 days without trauma. On physical examination, severe pain with crepitation was elicited at the hip region but not at the stifle. Radiographic examination and computed tomography revealed a Salter-Harris type 1 fracture of the femoral capital physis and dysplasia of the proximal tibial epiphysis. Spontaneous femoral capital physeal fracture was suspected and femoral head and neck osteotomy was performed. Treatment for proximal tibial dysplasia was not performed. On histopathologic examination of femoral head, a cluster of chondrocytes in a proliferative zone at the epiphyseal plate was observed. Therefore, spontaneous femoral capital physeal fracture was diagnosed. The patient recovered his gait, and no related clinical signs were observed during 6 months of follow-up.

Treatment of Hip Microinstability with Arthroscopic Capsular Plication: A Retrospective Case Series

  • Tatiana Charles;Marc Jayankura;Frederic Laude
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • Purpose: Hip microinstability is defined as hip pain with a snapping and/or blocking sensation accompanied by fine anatomical anomalies. Arthroscopic capsular plication has been proposed as a treatment modality for patients without major anatomic anomalies and after failure of properly administered conservative treatment. The purpose of this study was to determine the efficacy of this procedure and to evaluate potential predictors of poor outcome. Materials and Methods: A review of 26 capsular plications in 25 patients was conducted. The mean postoperative follow-up period for the remaining patients was 29 months. Analysis of data included demographic, radiological, and interventional data. Calculation of pre- and postoperative WOMAC (Western Ontario and McMaster Universities Osteoarthritis) index was performed. Pre- and postoperative sports activities and satisfaction were also documented. A P<0.05 was considered significant. Results: No major complications were identified in this series. The mean pre- and postoperative WOMAC scores were 62.6 and 24.2, respectively. The WOMAC index showed statistically significant postoperative improvement (P=0.0009). The mean satisfaction rate was 7.7/10. Four patients with persistent pain underwent a periacetabular osteotomy. A lateral center edge angle ≤21° was detected in all hips at presentation. We were not able to demonstrate any difference in postoperative evolution with regard to the presence of hip dysplasia (P>0.05), probably because the sample size was too small. Conclusion: Capsular plication can result in significant clinical and functional improvement in carefully selected cases of hip microinstability.

Highly Cited Articles in Periacetabular Osteotomy Research

  • Colin K. Cantrell;Cody J. Goedderz;Ryan S. Selley;Ernest L. Sink;Michael D. Stover
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.87-95
    • /
    • 2022
  • Purpose: The aim of this study is to identify highly cited articles and examine trends and characteristics in research on periacetabular osteotomy. Materials and Methods: The 50 most highly cited articles on periacetabular osteotomy research were identified using Scopus. Data regarding article demographics and publication were collected from each article and an analysis was performed. Results: The mean citation count was 125±37. The article with the highest total citation count (796), five-year citation count (327), and five-year citation density (65/year) was reported by Reinhold Ganz. The five-year citation density showed strong correlation with total citation density (r=0.930, P<0.001). Reinhold Ganz, the most productive author, was listed on 13 articles in the cohort with 455 weighted citation points. Conclusion: This study provides a collection of articles examining periacetabular osteotomies and demonstrates that citation count can be regarded as an acceptable measure of the contemporary academic influence of an article.

A 3D-printing Bone Model for Surgical Planning of Total Hip Replacement after Failed Triple Pelvic Osteotomy

  • Han, Kyungjin;Park, Jiyoung;Yoon, Jangwon;Lee, Young-Won;Choi, Ho-Jung;Jeong, SeongMok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.463-466
    • /
    • 2017
  • A 3-year-old, 26 kg, castrated male Chow Chow was presented for assessment of weight-bearing lameness of the left hind limb. The patient had a history of triple pelvic osteotomy on the left side to correct hip dysplasia 2 years prior to his presentation of clinical signs and underwent total hip replacement on the right coxofemoral joint 1 year later. Upon physical examination, pain and crepitus were noted on the left hip joint during extension. Radiological examination revealed coxofemoral joint subluxation and moderate degenerative bone changes on the left hip joint and pelvic axis, which relates to acetabular angles that were changed after triple pelvic osteotomy (TPO). Preoperative computed tomography was used for 3-dimensional printing to establish an accurate surgical plan. The changed angles of the acetabulum after TPO were evaluated, and rehearsal surgery was performed using a 3-demensional printing bone model. Three months after the THR surgery, the function of the affected limb had improved, with no lameness. Complications, such as luxation and implant failure, were not observed until 6 months after the operation. Accurate evaluation of acetabulum angles and rehearsal surgery using a 3D-printed bone model is effective for total hip replacement after unsuccessful TPO.

Application of a Modified Triple Pelvic Osteotomy for Treatment of Hip Dysplasia in Dogs (개의 고관절 이형성 치료를 위한 변형 3중 골반 절골술의 적용)

  • Kim Young-Sam;Lim Ji Hey;Jung Chang-soo;Byeon Ye-eun;Kanaya Tomohiro;Nagaoka Katsuyoshi;Kweon Oh-kyeong
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.328-335
    • /
    • 2005
  • The objective of this study was to evaluate tire effects of modified triple pelvic osteotomy(TPO). The procedures of modified TPO were composed of two iliac osteotomies and a pubic symphysiotomy at a tittle. Medical records of modified TPO treatment on 36 dogs and of unilateral TPO on 7 dogs were reviewed on the basis of signalment, body weight, operation time, Healing time of osteotomy sites and complications from October 2002 to September 2004. The values of clinical status and hip dysplasia, Norberg angle, percentage of femoral head coverage and pelvic diameter from radiographs taken preoperative, immediately postoperative, 2, 4, 8, 12 and 24 weeks after operation, respectively, were measured. In .unilateral TPO, the dogs could start standing without assistance from $3.0\pm1.0days$ and walking from $8.3\pm0.6days$ (n=3). Mean clinical grade before and 24 weeks after surgery were $2.2\pm0.42$(n=6) and $3.5\pm0.7$ (n=2), respectively. Mean operation time was $107.3\pm38.9$ minutes (n=4). In modified TPO, the dogs were seen to staff standing without assistance from $4.9\pm3.7$ days and walking from $7.3\pm4.8days$ (n=25). Mean clinical grade before surgery and 24 weeks after surgery were $2.3\pm1.5$ (n=27) and $3.2\pm0.7$)(n=9), respectively. Postoperative clinical grade significantly improved against preoperative clinical grade (P<0.01). Mean operation time was $143\pm42.8$ minutes (n=24). This was shorter than time f3r twice unilateral TPO. By comparison with preoperative values, postoperative mean radiographic grade, percentage of femoral head coverage and Norberg angle measured at the recheck time point significantly increased (P<0.01). Mean postoperative pelvic diameter was significantly larger than preoperative pelvic diameter in modified TPO (P<0.01) but not in unilateral TPO. These results indicated that modified TPO was effective technique for the treatment of hip dysplasia in dogs.