• Title/Summary/Keyword: hinge diaphragm

Search Result 4, Processing Time 0.019 seconds

A novel miniature condenser microphone with a hinge diaphragm (힌지구조를 갖는 초소형 콘덴서 마이크로폰)

  • Kim, Hye-Jin;Lee, Sung-Q;Park, Kang-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.174-178
    • /
    • 2007
  • This paper presents a novel, highly sensitive condenser microphone with a flexure hinge diaphragm. We used the finite-element analysis (FEA) to evaluate the mechanical and acoustic performance of the condenser microphone with a hinge diaphragm. And we fabricated the miniature condenser microphones with area of 1.5 mm${\times}$1.5 mm. From the simulation results, we confirmed that the maximum displacements at the center of flexure hinge diaphragms are several hundred times, compared with flat diaphragms. The sensitivities of fabricated miniature microphones are about $12.87{\mu}V/Pa$ at 1 kHz under a low bias voltage of 1 V, and the frequency response is flat upto 13 kHz.

Strategy to increase distortional rigidity of crane box girder: Staggered truss diaphragm

  • Yangzhi Ren;Wenjing Guo;Xuechun Liu;Bin Wang;Piyong Yu;Xiaowen Ji
    • Structural Engineering and Mechanics
    • /
    • v.86 no.4
    • /
    • pp.461-472
    • /
    • 2023
  • This paper proposes a novel method for increasing the distortional frame rigidity of off-rail box girder bridges for cranes by reinforcing the diaphragm with staggered truss. The study starts by using the Matrix Displacement Method to determine the shear angle of the staggered truss diaphragm under two assumptions: hinge joint and rigid joint. To obtain closed-form solutions for the transversal and longitudinal deformations and warping stress of the crane girder, the study employs the Initial Parameter Method and considers the compatibility of shear deformation at joints between the diaphragms and the girder. The theoretical solutions are validated through finite element analysis, which also confirms that the hinge-joint assumption accurately represents the shear angle of the staggered truss diaphragm in girder distortion. Additionally, the study conducts extensive parameter analyses to examine the impact of staggered truss dimensions on distortional stress and deformation. Furthermore, the study compares the distortional warping stresses of crane girders reinforced with staggered truss diaphragms and those reinforced with perforated ones, emphasizing the importance of incorporating stagger truss in diaphragms. Overall, this paper provides a thorough evaluation of the proposed approach's effectiveness in enhancing the distortional frame rigidity of off-rail box girder bridges for cranes. The findings offer valuable insights into the design and reinforcement of diaphragms using staggered truss to enhance the structural performance of crane girders.

Load Characteristics and Sensitivity Analysis for an Automotive Clutch Diaphragm Spring (자동차 클러치 다이어프램 스프링 하중 특성 및 민감도 해석)

  • Lee, Byoung-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • An analytical solution for deflection-load characteristics of a conical disk spring used especially in the automotive manual transmission clutch applications is proposed in order to take into account the effects of friction and large deformation. The conical disk spring, or the diaphragm spring, has a hinge support, an application point of release load at the tip of the fingers and an application point of clamp load near but inside the outer perimeter of the conical disk spring. The friction coefficient is assumed to be a constant regardless of the speed of deflection and the magnitude of loads. Comparison with experimental shows a good agreement with the analytical prediction. Also, the sensitivity of the clamp load due to variations in the geometrical parameters of the conical disk spring is calculated and discussed.

Mechanical performance of a new I-section weak-axis column bending connection

  • Lu, Linfeng;Xu, Yinglu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.26 no.1
    • /
    • pp.31-44
    • /
    • 2018
  • This paper reports a novel steel beam-to-column connection suitable for use in the weak axis of I-section column. Monotonic and cyclic loading experimental investigations and numerical analysis of the proposed weak-axis connection were conducted, and the calculation procedure of the beam-column relative rotation angle and plastic rotation angle was developed and described in details. A comparative analysis of mechanical property and steel consumption were employed for the proposed I-section column weak-axis connection and box-section column bending connection. The result showed that no signs of fracturing were observed and the plastic hinge formed reliably in the beam section away from the skin plate under the beam end monotonic loading, and the plastic hinge formed much closer to the skin plate under the beam end cyclic loading. The fracture of welds between diaphragm and skin plate would cause an unstable hysteretic response under the column top horizontal cyclic loading. The proposed weak-axis connection system could not only simplify the design calculation progress when I-section column is adopted in frame structural design but also effectively satisfy the requirements of 'strong joint and weak member', as well as lower steel consumption.