• Title/Summary/Keyword: higher mode effect

Search Result 522, Processing Time 0.034 seconds

Vortex-induced vibration characteristics of multi-mode and spanwise waveform about flexible pipe subject to shear flow

  • Bao, Jian;Chen, Zheng-Shou
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.163-177
    • /
    • 2021
  • Numerical simulations of the Vortex-Induced Vibration (VIV) about a large-scale flexible pipe subject to shear flow were carried out in this paper. Efficiency verification was performed firstly, validating that the proposed fluid-structure interaction solution strategy is competent in predicting the VIV response. Then, the VIV characteristics related to multi-mode and spanwise hybrid waveform about the flexible pipe attributed to shear flow were investigated. When inflow velocity rises, higher vibration modes are apt to be excited, and the spanwise waveform easily convertes from a standing-wave-dominated status to a hybrid standing-traveling wave status. The multi-mode or even multiple-dominant-mode is prone to occur, that is, the dominant mode is often followed by several apparent subordinate modes with considerable vibration energy. Hence, the shedding frequencies no longer obey Strouhal law, and vibration trajectories become intricate. According to the motion analysis concerning the coupled cross-flow and in-line vibrations, as well as the corresponding wake patterns, a tight coupling interaction exists between the structural deformation and the wake flow behind the flexible pipe. In addition, the evolution of the vortex tube along the pipe span and a strong 3D effect are observed due to the slenderness of the flexible pipe and the variability of the vortex shedding attributed to the shear flow.

Urban Aerosol Number Concentration and Scattering Coefficient in Seoul, Korea, during Winter (서울지역 겨울철 대기 에어로졸의 수 농도 및 산란계수 분석)

  • Lee, Hyun-Hye;Kim, Jin Young;Lee, Seung-Bok;Bae, Gwi-Nam;Yum, Seong Soo
    • Particle and aerosol research
    • /
    • v.6 no.2
    • /
    • pp.91-103
    • /
    • 2010
  • Size-segregated number concentration and scattering coefficient of urban aerosols were measured using an SMPS (scanning mobility particle sizer) and a nephelometer, respectively in Seoul, Korea, during the winter season of 2003. The average number concentrations of ultrafine particles (20~100 nm) and accumulation mode particles (100~600 nm) were $2,170\;particles\;cm^{-3}$ and $1,521\;particles\;cm^{-3}$, respectively. The scattering coefficient at the wavelength of 550 nm ranged from $62.6Mm^{-1}$ to $330.1Mm^{-1}$ and average value was $163.4Mm^{-1}$. The peak concentrations of ultrafine particles and accumulation mode particles were simultaneously recorded between 6:00 and 9:00 A.M., indicating the effect of vehicle emissions which are major air pollution sources in the urban atmosphere. On average, the number concentration of ultrafine particles was 1.4 times higher than that of accumulation mode particles, although it was a little higher during the morning peak time. The variation of aerosol scattering coefficient was in good agreement with that of accumulation mode particle number concentration rather than that of ultrafine particle number concentration.g coefficient was in good agreement with that of accumulation mode particle number concentration rather than that of ultrafine particle number concentration.

Analysis of Hydroelastic Response of a Pontoon-type Structure Considering Effect of Wave Breaker with Underwater Opening (해수순환 방파제를 고려한 폰툰형 구조물의 유탄성응답 해석)

  • 홍사영;최윤락;홍석원
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.5
    • /
    • pp.53-59
    • /
    • 2003
  • Ocean space utilization using VLFS(Very Large Floating Structures) can provide environmental impact free space by allowing sea water flow freely through the floating structure. Use of Pontoon type VLFS for that purpose needs employment of breakwaters for reduction of wave effects. Therefore, in order to maximize advantage of environmental impact free structure, the breakwater should be the one that can allow water flow freely through it, too. In this paper hydroelastic response of a pontoon type structure is analyzed considering breakwaters which allow water flow through its opening at bottom of the breakwaters. Mode superposition technique is used for solving equation of flexible body while interactions between the pontoon and breakwaters is considered based on generalized mode concept. Bi-quadratic nine node higher-order boundary element method is adopted for more accurate numerical treatment near sharp edged body shape. Performance of various combinations of breakwaters is investigated.

Effects of ground motion scaling on nonlinear higher mode building response

  • Wood, R.L.;Hutchinson, T.C.
    • Earthquakes and Structures
    • /
    • v.3 no.6
    • /
    • pp.869-887
    • /
    • 2012
  • Ground motion scaling techniques are actively debated in the earthquake engineering community. Considerations such as what amplitude, over what period range and to what target spectrum are amongst the questions of practical importance. In this paper, the effect of various ground motion scaling approaches are explored using three reinforced concrete prototypical building models of 8, 12 and 20 stories designed to respond nonlinearly under a design level earthquake event in the seismically active Southern California region. Twenty-one recorded earthquake motions are selected using a probabilistic seismic hazard analysis and subsequently scaled using four different strategies. These motions are subsequently compared to spectrally compatible motions. The nonlinear response of a planar frameidealized building is evaluated in terms of plasticity distribution, floor level acceleration and uncorrelated acceleration amplification ratio distributions; and interstory drift distributions. The most pronounced response variability observed in association with the scaling method is the extent of higher mode participation in the nonlinear demands.

Seismic Performance Evaluation of Multi-Span Bridges considering Effect of Lateral Load Distributions and Equivalent SDOF methods (횡하중 분포와 등가단자유도 방법의 영향을 고려한 다경간 교량의 내진성능 평가)

  • Song, Jong-Keol;Nam, Wang-Hyun;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.163-171
    • /
    • 2006
  • To evaluate inelastic seismic responses of multi-span-bridge, the equivalent single-degree-of-freedom (ESDOF) methods and the lateral load distributions are applied to the capacity spectrum method(CSM). From the pushover analysis results using the four ESDOF methods and the six types lateral load distributions, the ESDOF method more than lateral load distribution is found to have an important influence upon the pushover analysis. The effects of the higher mode on the bridge seismic behaviors are also increased as the number of pier increase. Therefore, it can be concluded that lateral load distributions and ESDOF methods for reflection of higher mode effects should be considered in the seismic analysis of the bridge structural.

  • PDF

The Control of Large Scale System by Sliding Mode (슬라이딩 모드를 이용한 대규모 계통의 제어)

  • Chun, Hee-Young;Park, Gwi-Tae;Kuo, Chun Ping;Kim, Dong-Sik;Im, Hyeong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.190-194
    • /
    • 1987
  • This paper describes a new method for control of large-scale system by sliding mode. The concepts of control to large-scale system on the basis of VSS(Variable Structure System) control theory are used to decompose a large control problem into a two-level algorithm such that each subsystem is stabilized with local discontinuous controllers and higher level corrective control is designed to take into account the effect of interaction among the subsystems. In this paper, we show that each subsystem is controlled with repect to local continuous and higher level corrective control. This algorithm can be easily applied to multi-variable control system and obtained a continuous control in comparison With variable structure control systems. Two numerical examples are discussed as illustrations.

  • PDF

Detecting width-wise partial delamination in the composite beam using generalized fractal dimension

  • Kumar, S. Keshava;Ganguli, Ranjan;Harursampath, Dineshkumar
    • Smart Structures and Systems
    • /
    • v.19 no.1
    • /
    • pp.91-103
    • /
    • 2017
  • Generalized fractal dimension is used to detect the presence of partial delamination in a composite laminated beam. The effect of boundary conditions and location of delamination on the fractal dimension curve is studied. Appropriability of higher mode shape data for detection of delamination in the beam is evaluated. It is shown that fractal dimension measure can be used to detect the presence of partial delamination in composite beams. It is found that the torsional mode shape is well suited for delamination detection in beams. First natural frequency of delaminated beam is found to be higher than the healthy beam for certain small and partial width delaminations and some boundary conditions. An explanation towards this counter intuitive phenomenon is provided.

Electromagnetic field and initial stress on a porothermoelastic medium

  • Abd-Elaziz, Elsayed M.
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • In this study, the porothermoelastic problem with the effect of the magnetic field and initial stress was investigated. We applied normal mode analysis to solve the resulting non-dimensional coupled equations. Numerical results for the displacements, temperature distribution, pore pressure, stresses, induced electric field and induced magnetic field distributions are presented graphically and discussed. The medium deformed because of thermal shock and due to the application of the magnetic field, there result an induced magnetic and an induced electric field in the medium. Numerical analyses are given graphically on the square (2D) and cubic (3D) domains to illustrate the effects of the porosity parameter, magnetic field and initial stress parameter on the physical variables.

Effect of Fuels on $CO_2$ Emission in CVS-75 Mode (CVS-75모드에서 사용연료에 따른 자동차의 이산화탄소 배출특성)

  • Kim, Yong-Tae;Lee, Ho-Kil;Kang, Jung-Ho;Chung, Jae-Woo;Chung, Yon-Jong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.72-78
    • /
    • 2009
  • The regulation for $CO_2$ emissions from vehicles have become much more stringent in recent years. These more stringent regulations request vehicle manufacturers to develop alternative fuels to reduce exhaust emissions. In this paper, $CO_2$ emission of gasoline, diesel and LPG vehicles in the CVS-75mode is analyzed. The experimental results indicated that the cold starting acceleration period of $CO_2$ emission was much longer compared to the hot start acceleration period. For example, gasoline vehicle and LPG fuel vehicle had 21% higher $CO_2$ emission and diesel vehicle had 34% higher $CO_2$ emission.

Comparison of Venting Modes for Bench Scale Treatment of Diesel Contaminated Soil (디젤오염토양의 Bench Scale 처리에 있어서 벤팅모드 비교)

  • Kim, Young-Am;Lee, Yong-Hee;Lee, Dong-Sun;Suh, Myung-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.499-505
    • /
    • 2006
  • Bioventing efficiency was compared in a continuous and an intermittent(6hr injection and 6hr rest) air injection mode. Two lab-scale columns which packed with 5 kg of soil artificially contaminated by diesel oil were operated. The columns were maintained at the $25^{\circ}C{\pm}2.5$ in order to minimize the effect of exterior temperature variation. The flow rate of air injection mode were maintained constantly at the flow rate of 10 ml/min. The moisture of the columns was stably maintained at $60{\sim}80%$ of field capacity. The nutrient compounds were added to make C:N:P ratio as 100:10:l. The continuous and intermittent injection modes showed 67.56% and 69.63% reduction of initial TPH concentration during 90 days, respectively. Two venting modes showed similar results in the analysis of the trends of the hydrocarbon utilizing bacterial counts for operating periods. The carbon dioxide production rate of the continuous injection mode was higher than that of intermittent injection mode. The loss of diesel oil by volatilization in the continuous and intermittent injection modes were about 5% and 1%, respectively. The lower volatilization loss in the intermittent injection mode suggested that the biodegradation of TPH in the intermittent injection mode was greater than that of the continuous mode. These results suggested that the intermittent injection mode is more efficient than the continuous venting mode.