• 제목/요약/키워드: high-tc superconducting fault current limiter(SFCL)

검색결과 54건 처리시간 0.025초

자속 구속형 고온초전도 전류제한기의 동작특성 분석 (The Analysis of Operation Characteristics of Flux-Lock Type High-Tc Superconducting Fault Currents Limiter)

  • 박충렬;임성훈;박형민;이종화;고석철;최효상;한병성;현옥배;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1130-1132
    • /
    • 2004
  • In this paper, we investigated the operational characteristics of the fault current limiting in the The flux-lock type high-Tc superconducting fault current limiter. The flux-lock type high-Tc superconducting fault current limiter was consisted of primary and secondary copper coils that flux was locked on iron core and YBCO thin film. The operational characteristic of a flux-lock type SFCL dependent on winding direction of coil 1 and coil 2, and the number of turns of coil 1 and coil 2, inductances of the coils, saturation in iron core, the properties of superconducting element etc. In this cases, we investigated the fault currents limiting characteristics of the flux-lock type SFCL when winding direction of coil 1 and coil 2 was subtractive polarity winding.

  • PDF

저항형 고온 초전도 전류제한기의 저항변화 분석 (Anaysis of resistance variance of Resistive type high-Tc superconducting fault current limiter)

  • 박형민;최효상;임성훈;박충렬;한병성;정헌상;최창주;현옥배;정동철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.547-550
    • /
    • 2004
  • Superconducting fault current limiter(SFCL) is expected to be introduced into electric power system in future as an effective countermeasure for the increase of the short-circuit current due to the growth of the electric power system. SFCL has a merit that the fault current can be limited by the resistance generated when a superconductor transits from a superconducting state to a normal state without additional detecting device. In this paper, we investigated the resistance variance of resistive type SFCL and the fault current limiting characteristics due to the amplitude of source voltage. We could obtain the more effective fault current limiting characteristics of SFCL as the source voltage increased.

  • PDF

고온초전도 한류기의 전력계통 적용에 관한 연구 (A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter)

  • 배형택;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

DC 리액터형 고온초전도한류기를 위한 전력변환기의 dual-mode 운전특성 (The Operation Characteristics of Dual-mode Power Converter for DC Reactor Type Superconducting Fault Current Limiter)

  • 전우용;이승제;안민철;이안수;윤용수;윤경용;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.43-46
    • /
    • 2003
  • The dc reactor type high-Tc superconducting fault current limiter(SFCL) is composed of three parts, a power converter, a magnetic core reactor(MCR) and a dc reactor. This study concerned with the power converter of the DC reactor type high-Tc SFCL. The rectifying devices which power converter of 6.6kV/200A SFCL consists of have to endure high voltage. We propose the dual mode power converter to reduce the voltage which each rectifying device endures. In the single phase the experiment and simulation of dual mode power converter and the simulation of power converter with one bridge rectifier are performed. The current of each system with different power converter has a same tendency and the voltage which rectifying device of dual mode power converter endures is reduced in half by comparison with that of power converter with one bridge rectifier. We found dual mode power converter can be applied to SFCL.

  • PDF

이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석 (Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types)

  • 이신원;한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.136-140
    • /
    • 2011
  • The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.

저항형 고온초전도 소자의 스위칭 동작을 이용한 브리지형 고온초전도 전류제한기의 동작 특성 (Operational Characteristics of Bridge Type SFCL Using Switching Operation of Resistive Type HTSC Element)

  • 임성훈;이상일;최효상;한병성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.619-623
    • /
    • 2004
  • We proposed the bridge type superconducting fault current limiter(SFCL) using switching operation of high-Tc superconducting(HTSC) thin film. The proposed bridge type SFCL consists of HTSC thin film, a diode bridge and a dc reactor. The controller for the operation of an interrupter is required in the conventional bridge type SFCL to prevent the continuous increase of fault current after a fault happens. On the other hand, the proposed bridge type SFCL can limit the fault current without the interrupter and the controller for its operation by the resistance generated when the gradually increased fault current exceeds HTSC thin film's critical current. We calculated the time when the gradually increased fault current started to be limited by the resistance generated in HTSC thin film after a fault happened and confirmed that it could be dependent on the amplitude of source voltage. The experimental results well agreed with the calculated ones from simulation.

Improvement of Current Limiting and Recovery Characteristics of Flux-Lock Type SFCL with Series Connection of Two Coils Using Its Third Coil

  • Ko, Seok-Cheol;Kim, Young-Pil;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.472-477
    • /
    • 2017
  • In this work, the current limiting and recovery characteristics of a flux-lock type superconducting fault current limiter (SFCL) with series connection of two coils were effectively improved by adding a third winding into the conventional flux-lock type SFCL with series connection of two coils. To confirm the contribution of the third winding to the current limiting and recovery characteristics of this type of the SFCL, short-circuit testing was carried out with consideration of the third winding, and the effect of the third winding on the current limiting and recovery characteristics was examined by comparative analysis of the amplitude of the limited fault current and the power burden of the high-TC superconducting (HTSC) element comprising the SFCL. Through the analysis of both the limiting impedance and the operational current as the main design parameter of the SFCL, the improved current limiting and recovery characteristics of the flux-lock type SFCL using the third winding could be verified.

이중 ?치를 이용한 변압기형 초전도 한류기의 권선전류와 초전도소자 저항에 따른 전력소모 및 누적에너지 분석 (Analysis on Power Consumption and Accumulated Energy According to Resistance of Superconducting Element and Winding Current of Transformer Type SFCL Using Double Quench)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.630-634
    • /
    • 2016
  • In this paper, we analyzed the power consumption and the accumulated energy in HTSC (high-TC superconducting elements) according to the resistance of HTSC element and the winding current of transformer type SFCL (superconducting fault current limiter) using double quench. For the analysis, two different inductances of the one secondary winding among two secondary windings comprising the transformer type SFCL were selected and the short-circuit tests were carried out. The consumed power and the accumulated energy in HTSC element connected into the secondary winding with larger inductance were analyzed to be larger compared to the one connected into the secondary winding with lower inductance.

직렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 사고전류제한 특성 시뮬레이션 및 실험 분석 (Analysis on Simulation and Experiment for Fault Current Limiting Characteristics of SFCL using Magnetic Coupling of Two Coils with Series Connection)

  • 김재철;임성훈;김진석;안재민;문종필
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.26-30
    • /
    • 2008
  • 본 논문에서는 본 저자가 제안한 직렬연결된 두 코일의 자기결합을 갖는 초전도 전류제한기의 사고전류제한 시뮬레이션과 실험을 수행하였다. 평상시에는 두 코일로부터 발생되는 자계는 상쇄되지만 사고가 발생되면 초전도 소자의 저항발생으로 더 이상 두 코일로부터 자계는 상쇄되지 않게 되고 제한기 임피던스 발생으로 고장전류가 제한된다. 제안한 자기결합을 이용한 초전도 전류제한기의 두 코일의 인덕턴스비를 조절함으로써 제한기의 동작전류와 임피던스는가 향상될 수 있음을 시뮬레이션과 실험을 통해 확인할 수 있었다.