• Title/Summary/Keyword: high-intensity ultrasound

Search Result 94, Processing Time 0.028 seconds

Comparative Study on Signal Strength of Mechanical Index Using Ultrasound Machines with SonoVue Contrast (Sonovue 초음파 조영제를 이용한 장비 간 Mechanical Index의 변화에 따른 신호 강도 비교연구)

  • Kim, Myung-Seok;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of this study was to compare the MI using SonoVue along with different machines output and to infer the meaning of the signal difference under the same condition. All of the comparative instruments showed strong signal values at early stage as MI value increased. Over time, the inter-instrumental signal values showed signal attenuation under all conditions except for 10 min of the condition of MI 0.1 of RS85A. E9 and EPIQ7 showed signal degradation due to microbubble collapse over time at all MI values. In the comparison of equipment, the signal strengths of MI 0.1, 0.2, and 0.4 were high in order of EPIQ7, RS85A and E9. In the quantitative analysis, there were statistically significant from the SNR and CNR that were obtained from RS85A and E9 (P-value<0.05). In the quantitative analysis, Epiq7 was statistically significant except for CNR as the MI value was changed In the contrast-enhanced ultrasound, even though MI value was low (MI <0.05), it will be helpful for diagnosis, controlling the MI and scan time because a difference in signal intensity was shown between the three machines.

The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer (전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향)

  • Lee, Ji-Hae;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Re-Na;Kim, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. Materials and Methods: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. Results: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was $299{\pm}155\;mL$ in the experimental group, as opposed to $187{\pm}155\;mL$ in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. Conclusion: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.

Development of portable single-beam acoustic tweezers for biomedical applications (생체응용을 위한 휴대용 단일빔 음향집게시스템 개발)

  • Lee, Junsu;Park, Yeon-Seong;Kim, Mi-Ji;Yoon, Changhan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.435-440
    • /
    • 2020
  • Single-beam acoustic tweezers that are capable of manipulating micron-size particles in a non-contact manner have been used in many biological and biomedical applications. Current single-beam acoustic tweezer systems developed for in vitro experiments consist of a function generator and a power amplifier, thus the system is bulky and expensive. This configuration would not be suitable for in vivo and clinical applications. Thus, in this paper, we present a portable single-beam acoustic tweezer system and its performances of trapping and manipulating micron-size objects. The developed system consists of an Field Programmable Gate Array (FPGA) chip and two pulsers, and parameters such as center frequency and pulse duration were controlled by a Personal Computer (PC) via a USB (Universal Serial Bus) interface in real-time. It was shown that the system was capable of generating the transmitting pulse up to 20 MHz, and producing sufficient intensity to trap microparticles and cells. The performance of the system was evaluated by trapping and manipulating 40 ㎛ and 90 ㎛ in diameter polystyrene particles.

Ultrasonic dissection versus electrocautery for immediate prosthetic breast reconstruction

  • Lee, Dongeun;Jung, Bok Ki;Roh, Tai Suk;Kim, Young Seok
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.20-25
    • /
    • 2020
  • Background Ultrasonic dissection devices cause less thermal damage to the surrounding tissue than monopolar electrosurgical devices. We compared the effects of using an ultrasonic dissection device or an electrocautery device during prosthetic breast reconstruction on seroma development and short-term postoperative complications. Methods We retrospectively reviewed the medical records of patients who underwent implant-based reconstruction following mastectomy between March 2017 and September 2018. Mastectomy was performed by general surgeons and reconstruction by plastic surgeons. From March 2017 to January 2018, a monopolar electrosurgical device was used, and an ultrasonic dissection device was used thereafter. The other surgical methods were the same in both groups. Results The incidence of seroma was lower in the ultrasonic dissection device group than in the electrocautery group (11 [17.2%] vs. 18 [31.0%]; P=0.090). The duration of surgery, total drainage volume, duration of drainage, overall complication rate, surgical site infection rate, and flap necrosis rate were comparable between the groups. Multivariate analysis revealed that the risk of seroma development was significantly lower in the ultrasonic dissection device group than in the electrocautery group (odds ratio for electrocautery, 3.252; 95% confidence interval, 1.242-8.516; P=0.016). Conclusions The findings of this study suggest that the incidence of seroma can be reduced slightly by using an ultrasonic dissection device for prosthesis-based breast reconstruction. However, further randomized controlled studies are required to verify our results and to assess the cost-effectiveness of this technique.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

A Case Report of Axillary Hibernoma: US, CT, MR, and Histopathologic Findings (액와부 갈색지방종의 증례 보고: 초음파, 컴퓨터단층촬영, 자기공명영상, 병리 소견)

  • Ji Yeon Park;Seong Yoon Yi;Ji Young Lee;Tae Jung Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.439-443
    • /
    • 2022
  • Hibernoma is a rare benign tumor of brown adipose tissue. Herein, we report a case of axillary hibernoma in a 53-year-old female and discuss the various radiologic findings. The US revealed a 4.5-cm well-defined oval heterogenous hyperechoic mass in the right axilla with anterior displacement of the axillary vessels. Non-enhanced chest CT showed a 5.0-cm well defined, oval, and low-attenuated mass. MRI demonstrated a 5.5-cm mass with heterogeneous intermediate-to-high signal intensity on T1-and T2-weighted images and irregular enhancement at the peripheral portion. The patient underwent an US-guided core needle biopsy and the final diagnosis was hibernoma.

Syntheses of Disubstituted Polysilanes (Ⅱ): Sonochemical Study (폴리실란의 합성 (Ⅱ): 초음파 화학적 연구)

  • 이규환;전태하
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.28-42
    • /
    • 1999
  • Polysilanes with sterically bulky substituents, -[2-( $R^1R^2$-phenyl)propyl]Si[$R^3$]-, such as poly(2-phenylpropyl)(n-hexyl)silane [$R^1=R^2$=H, $R^3$=n-hexyl] were prepared by Wurtz-type coupling reactions with Na using a sonochemical method. The high-intensity ultrasound provided the formation of high quality Na dispersion in toluene and its active surface which was important for the synthesis of polysilanes in Wurtz-type coupling reaction was freshly and continuously regenerated during the process. The polysilanes products were mixtures of high molecular weight polymers with $\={M}_W$ of ∼$10^6$ and low molecular weight polymers with $\={M}_W$ of ∼$10^3$. It was found that the formation of high molecular weight polymerr was greatly influenced by the substituents $R^3$, directly attached to Si. On the contrary, changes on substituents ($R^1, R^2$) gave no influences at all. Overall yields for polysilanes were 75-99% in general but high molecular weight polysilanes were obtained as a major product when substituent $R^3$ is n-hexyl group and low molecular weight polysilanes were obtained as a major product when substituent $R^3$ is cyclohexyl and 2-phenylethyl groups. Effects of reaction conditions to polysilane yields were investigated.

  • PDF

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Imaging Findings of Metaplastic Breast Carcinoma with Chondroid Differentiation: A Case Reports (연골성 분화를 보이는 화생성 유방암의 영상의학적 소견: 증례 보고)

  • Ji-Young Kim;Soung Hee Kim;Myeong Ja Jeong;Ji Hae Lee;Mi-Jin Kang;Geumhee Gwak;Su Hyun Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1385-1393
    • /
    • 2022
  • Metaplastic carcinoma of the breast is a heterogeneous group of neoplasms with mixed epithelial and mesenchymal differentiation. Metaplastic carcinoma of the breast is a rare and aggressive malignancy, with high recurrence and metastasis. Metaplastic carcinoma with chondroid differentiation is an uncommon subtype that tends to have a relatively good prognosis than that of other subtypes. We report the imaging features of three cases of pathologically proven metaplastic carcinoma with chondroid differentiation as follows: a high-density mass with amorphous or coarse heterogeneous calcifications on mammography; a microlobulated or partially indistinct, complex cystic, and solid mass on sonography; and a relatively circumscribed or partially indistinct, irregular mass with heterogeneous T2 high-signal intensity and heterogeneous or rim enhancement with initial fast enhancement and delayed washout on MRI.

Clinical Outcome of Treatment for Stage IIA, IIB and III Osteosarcomas (Comparative Studies between Invasive Surgical Treatment and Non-invasive HIFU Technique) (진행된 장관골 골육종의 수술 및 비수술적 강력 집속 초음파 치료의 장기 추적 결과)

  • Wenzhi, Chen;Wei, Wang;Zhibiao, Wang;Hui, Zhu;Kequan, Li;Hao, Piao Xiang;Haibing, Su;Chengbing, Jin;Feng, Wu;Jin, Bai;Rhee, Seung-Koo;Kang, Yong-Koo;Bahk, Won-Jong;Chung, Yang-Guk;Huh, Sung-Woo;Lee, Eun-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2006
  • Purpose: To evaluate the end results between the surgical treatment with neo-adjuvant chemotherapy in Korea and non-invasive high intensity focused ultrasound (HIFU) technique in China for osteogenic sarcomas. Materials and Methods: The surgical treatment with neoadjuvant chemotherapy for total 67 cases (4 IIA, 58 IIB, and 5 III) in Korea since 1993 and the HIFU therapy for total 71 cases (57 II and 14 III) in China since 1997 was performed. In Korea, neo-adjuvant chemotherapy in 66 cases out of total 67 patients, but the adjuvant chemotherapy in only one case was done. On the contrary, in China, full chemotherapy for more than 9 times for 37 patients with stage II out of total 71 cases, but for less than 8 times of partial chemotherapy for 23 patients (stage II) and 14 patients (stage III) was done. The surgical treatment in total 67 Korean patients was done with wide resection and reconstruction for 56 patients, but wide resection without reconstruction for 5 patients and amputation for 6 patients. In china, total 71 patients was treated with average 1.5 times (1~4 times) of HIFU, and if there are some evidences of residual tumor after HIFU with following MRI, the second HIFU therapy was given 2~4 weeks later. After then, the bony defect was in no touch, keep bracing for long time expecting regeneration. All of them were followed for average 46 Mo (12~150 Mo) in Korea, but followed for average 22 Mo (9 years~8 months) in China. Results: The 5 year survival rate (stage II), was average 92.7% (IIA 100%, IIB 85.5%) in Korea series, and average 78.7% (full chemotherapy 91.8%, part chemotherapy 56.6%) in China series. The 3 year survival rate (stage III) was 20% in Korea and 7.1% in China. So, the final overall survival rate was 65.2% in Korea and 51.8% in China. The overall functional outcome score by ISOLS was 24.3 (81%) in Korea and 19.8 (73%) in China. There are 25.4% (17/67 cases) of complications in Korea and 31% (27 complications in 22 patients out of total 71 cases) in China after each treatment. Conclusions: The end results of Korea series which was treated with neoadjuvant chemo- and surgical methods are better than that of non-invasive thermal ablation in china. But we also believe the HIFU, as one of, was also effective to decrease the local recurrence and symptomatic releaf for stage II or even in III of osteogenic sarcomas.

  • PDF