• Title/Summary/Keyword: high-frequency core

Search Result 479, Processing Time 0.026 seconds

The Optimum Structure Design of 1005 RF Chip Inductors for GHz Band (GHz 대역을 위한 1005 RF 칩 인덕터의 최적 구조 설계)

  • Kim, Jae-Wook;Ryu, Chang-Keun
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.785-788
    • /
    • 2005
  • In this study, micro-scale, high-performance, solenoid-type RF chip inductors were investigated. The size of the RF chip inductors fabricated in this work was $1.0{\times}0.5{\times}0.5mm^3$ The material and shape of the core were 96% $Al_2O_3$ and I-type. The material and number of turn of coil were copper (Cu) and 6. The diameter ($40{\mu}m$) of coil and length (0.35mm) of solenoid were determined by a Maxwell three-dimensional field simulator to maximize the performance of the inductors. High frequency characteristics of the inductance (L) and quality-factor (Q) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). The inductors developed have inductances of 10.8nH and quality factors of 25.2 at 250MHz, and show results comparable to those measured for the inductors prepared by CoilCraftTm that is one of the best chip inductor company in the world. The simulated data predicted the high-frequency data of the Land Q of the inductors developed well.

  • PDF

The Study of the Ferrite Transformer Design for the Development of the High-frequency Battery Charger (고주파방식 충전기 개발을 위한 페라이트 변압기 설계에 관한 연구)

  • 안용호;박종광;김상준;윤장완;윤기웅;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.683-686
    • /
    • 2000
  • The chargers for DC power supply of the contro1lers, which have been installed in the relay rooms in 345/154kV substations of KEPCO, lag in both aspects of technique and performance. Moreover, as they are SCR-based, they dont meet the performance requirements of todays digital and automated controllers. Now two controllers are running in pair and one of those is for reservation. There are lots of troubles because the patrol engineering team has to replace them manually whenever they are out of order. So it is expected to bring convenience if the charger replacement is automated. Also, the existing chargers take much space, weight and cost - which have increased the need of development to make them smaller, less expensive, and have high quality. We will develop a charger system which has one fifth of the weight of the existing system by double-integrating the volume. The new system will be ready for a future full unmanned system with integrated pores for remote control, state-of-the-art digital features, and more than 90% efficiency/power factor against 80% efficiency/power factor of the existing system.

  • PDF

Influence of Different Frequency Harmonic Generated by Rectifier on High-speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Yang, Cunxiang;Fan, Xiaobin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1956-1964
    • /
    • 2018
  • Since the stator winding of High-Speed Permanent Magnet Generator (HSPMG) has few winding turns and low inductance value, it is more prone to be influenced by harmonic current. Moreover, the operation efficiency and the torque stability of HSPMG will be greatly influenced by harmonic current. Taking a 117 kW, 60 000 rpm HSPMG as an example, in order to analyze the effects of harmonic current on HSPMG in this paper, the 2-D finite element electromagnetic field model of the generator was established and the correctness of the model was verified by testing the generator prototype. Based on the model, the losses and torque of the generator under different frequency harmonic current were studied. The change rules of the losses and torque were found out. Based on the analysis of the influence of the harmonic phase angle on torque ripple, it is found that the torque ripple could be weakened through changing the harmonic phase angle. Through the analysis of eddy current density in rotor, the change mechanism of the rotor eddy current loss was revealed. These conclusions can contribute to reduce harmonic loss, prevent demagnetization fault and optimize torque ripple of HSPMG used in distributed power supply system.

Three-D core multiphysics for simulating passively autonomous power maneuvering in soluble-boron-free SMR with helical steam generator

  • Abdelhameed, Ahmed Amin E.;Chaudri, Khurrum Saleem;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2699-2708
    • /
    • 2020
  • Helical-coil steam generator (HCSG) technology is a major design candidate for small modular reactors due to its compactness and capability to produce superheated steam with high generation efficiency. In this paper, we investigate the feasibility of the passively autonomous power maneuvering by coupling the 3-D transient multi-physics of a soluble-boron-free (SBF) core with a time-dependent HCSG model. The predictor corrector quasi-static method was used to reduce the cost of the transient 3-D neutronic solution. In the numerical system simulations, the feedwater flow rate to the secondary of the HCSGs is adjusted to extract the demanded power from the primary loop. This varies the coolant temperature at the inlet of the SBF core, which governs the passively autonomous power maneuvering due to the strongly negative coolant reactivity feedback. Here, we simulate a 100-50-100 load-follow operation with a 5%/minute power ramping speed to investigate the feasibility of the passively autonomous load-follow in a 450 MWth SBF PWR. In addition, the passively autonomous frequency control operation is investigated. The various system models are coupled, and they are solved by an in-house Fortran-95 code. The results of this work demonstrate constant steam temperature in the secondary side and limited variation of the primary coolant temperature. Meanwhile, the variations of the core axial shape index and the core power peaking are sufficiently small.

Sound-Insulation Design of Aluminum Extruded Panel in Next-Generation High-Speed Train (차세대 고속철도 차량용 알루미늄 압출재의 차음 설계)

  • Kim, Seock-Hyun;Seo, Tae-Gun;Kim, Jeong-Tae;Song, Dal-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.567-574
    • /
    • 2011
  • Aluminum extruded panels are widely used instead of corrugated steel panels for weight reduction in high-speed trains. Of the layers in the train body, it makes the largest contribution to the sound insulation. However, compared with that of a flat panel with the same weight, the TL of the aluminum extruded panel is remarkably lower in the local resonance frequency band. We study aluminum extruded panels for next-generation 400-km/h trains. We investigate the problem of sound insulation and propose a practical method to improve the sound-insulation performance. The local resonance frequency region is increased by a modification of the core structure, and urethane foam is placed in the core. The effect on the sound insulation is verified by experiments. Finally, the improvement for the entire sound-transmission loss is estimated for the layered floor panels of express trains.

Perceived Competency, Frequency, Training Needs in Physical Assessment among Registered Nurses

  • Oh, Heeyoung;Lee, Jiyeon;Kim, Eun Kyung
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.6
    • /
    • pp.627-634
    • /
    • 2012
  • Purpose: The purpose of this study was to identify registered nurses learning needs about physical assessment. Specifically, what are the perceived competency, frequency of skill use and the unmet training needs. Methods: The study was an exploratory survey study. The sample was 104 registered nurses. Data were collected through three instruments: The Perceived Competency in Physical Assessment Scale, the Frequency of Physical Assessment Scale, and the Training Needs of Physical Assessment Scale which incorporated 30 core Physical Assessment skills. Descriptive statistics, t-test, and Pearson's correlation coefficient were used to analyze the data. Results: Auscultation of heart and lung sounds and inspection of the spine were rated by the subjects as physical assessment skills they feel least competent and also were less frequently performed. The most competent area for physical assessment was neurological system. The respiratory and abdominal system was identified as two systems that more education would be needed. Nurses with less than one year of working experience reported needing more training. Nurses with more than five years of clinical work experience performed physical assessment more frequently than nurses with less than five year of work experience. The perceived competency was positively related to the frequency of physical assessment. Conclusion: Continuing education is necessary to further train registered nurses regarding physical assessment skills and the program needs to be focused on the area which nurses are less competent for and have high training need.

A New Method for Thumbnail Extraction in H.264/AVC Bitstreams (H.264/AVC 비트스트림에서 썸네일 추출을 위한 새로운 방법)

  • Hong, Seung-Hwan;Kim, Ji-Eon;Chin, Young-Min;Kwon, Jae-Cheol;Oh, Seoung-Jun
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.853-867
    • /
    • 2010
  • Recently, thumbnail techniques are required to index a high-performance video at digital convergence-based multimedia service like IPTV and DMB. Therefore a thumbnail extraction method in H.264/AVC bitstreams has been proposed. However, thumbnail quality deterioration problem at converting the general equation of spatial domain to frequency domain which is generated by not considering about H.264/AVC transform and quantization processing and rounding-off operation in intra prediction. In this paper, we propose a new thumbnail extraction method in H.264/AVC bitstreams. The proposed scheme is based on H.264/AVC core-transform for a thumbnail extraction in frequency domain, and probability theory, intra rounding-off error compensation. Through the implementation and performance evaluation, the subjective quality difference between the output of our scheme and the output of reference decoder is negligible and better than the conventional method, and moreover PSNR gain by up to 8.66 dB.

Digital Relaying Algorithm for Power Transformer Protection using Fuzzy Logic Approach

  • Park, Chul-Won;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.153-159
    • /
    • 2002
  • Power transformer protective relay should block the tripping during magnetizing inrush and rapidly operate the tripping during internal faults. Recently, the frequency environment of power system has been made more complicated and the quantity of 2nd frequency component in inrush state has been decreased because of the improvement of core steel. And then, traditional approaches will likely be maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmonic component. This paper proposes a new relaying algorithm to enhance the fault detection sensitivities of conventional techniques by using a fuzzy logic approach. The proposed fuzzy based relaying algorithm consists of flux-differential current derivative curve, harmonic restraint, and percentage differential characteristic curve. The proposed relaying was tested with relaying signals obtained from EMTP simulation package and showed a fast and accurate trip operation.

The Effect of Ferrite Cores on the Inductively Coupled Plasma Driven at 13.56 MHz (13.56 MHz 유도 결합 플라즈마에서의 강자성체 페라이트 코어의 효과)

  • Lee, Won-Ki;Lee, Kyeong-Hyo;Chung, Chin-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.3 s.12
    • /
    • pp.35-38
    • /
    • 2005
  • Due to high permeability of the ferrite cores, the characteristics of the inductively coupled plasma(ICP) are expected to be greatly improved. We investigated the effect of the ferrite cores on conventional inductively coupled plasma. It was observed that the current and voltage in the ICP antenna are slightly decreased and the power transfer efficiency is increased. However, due to eddy current and hysteresis loss, plasma density in the ICP with the ferrite cores is not increased. It seems that the ICP with the ferrite cores at low frequency ($\∼$100 kHz) will be greatly improved since the losses at the low frequency can be negligible.

  • PDF

Design and Analysis of the 2-Phase SRM for High Speed Blower System (고속 블로워 시스템용 2상 SRM의 설계 및 해석)

  • Lee, Dong-Hee;Khoi, Huynh Khac Minh;Tanujaya, Marully;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.139-141
    • /
    • 2009
  • This paper presents a design and analysis of torque characteristics of a two-phase SRM(Switched Reluctance Motor) for high speed blower system. To reduce the electrical frequency and core losses at high speed region, In order to reduce torque ripple and torque dead-band, variable rotor air-gap structure is adopted and the air-gap is optimized according to torque production. The optimized torque output is verified by the FEM results.

  • PDF