• 제목/요약/키워드: high-flowing

검색결과 669건 처리시간 0.024초

적산온도에 의한 고유동콘크리트의 압축강도 예측 (Prediction of the Compressive Strength of High Flowing Concrete by Maturity)

  • 길배수;한장현;김규용;권영진;남재현;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.281-286
    • /
    • 1998
  • The aim of this study is to compare the development of compressive strength of high-Flowing concrete with maturity and to investigate the applicability of strength prediction models of concrete. An experiment was attempted on the high-flowing concrete mixes using Ordinary portland cement, High belite cement, Blast furance slage cement and replaced Fly-ash of 30% by weight of Ordinary portland cement, the water-binder ratios of mixes being 0.35 and the curing temperatures being 30, 20, 10, 5$^{\circ}C$. Test results of mixes are statistically analyzed to infer the correlation coefficient between the maturity and the compressive strength of high-flowing concrete.

  • PDF

보통강도 고유동 자기충전 콘크리트의 수화발열 특성 (Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength)

  • 최연왕;김병권;이재남;류득현;송용규;정우용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.497-500
    • /
    • 2008
  • 본 연구에서는 보통강도 고유동 자기충전 콘크리트의 수화발열 특성을 알아보기 위하여 미소수화열 시험 및 간이 단열에 의한 콘크리트 온도 상승량 실험을 실시하였다. 미소수화열 시험을 실시한 결과 석회석미분말 및 플라이애시를 혼화재로 사용한 고유동 자기충전 콘크리트는 단위시멘트량 감소로 수화발열량이 감소하였다. 간이 단열에 의한 콘크리트 온도 상승량을 측정한 결과 분체량이 많은 고유동 자기충전 콘크리트가 혼화재의 영향으로 온도저감 성능이 우수 하며, 3성분계 고유동 자기충전 콘크리트의 경우 일반콘크리트와 유사한 온도상승속도를 나타내었다. 이러한 결과 고유동 자기충전 콘크리트가 일반콘크리트보다 상대적으로 높은 단위 분체량에 대한 온도저감 성능이 우수 하며, 설계기준강도 30MPa의 3성분계가 2성분계 고유동 자기충전 콘크리트보다 온도저감 및 초기 수화발현에 유리할 것으로 판단된다.

  • PDF

세골재의 조립율에 따른 고유동콘크리트의 유동특성에 관한 실험적 연구 (An Experimental Study on the Fludity of High Flowing Concrete according to the Fineness Modulus of Fine Aggregate)

  • 박유신;강석표;조성현;최세진;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 1997
  • In the mixing proportion of high flowing concrete we have to use quantity of power such as cement and superplasticizer, and increase the proportion of fine aggregate more than that of plain concrete to increase flowability and segregation resistance. Therefore, the fresh state of high flowing concrete is largely affected by superplasticizer and change of grade the percentage of surface water. This study aims at development of self-filling up high flowing concrete without compaction, in case of using the fine aggregate of standard grade range, by examination on the influence of fresh state of high flowing concrete, and by understanding influence on various fluidity such as flowability, reinforcement passibility, fillingability, segregation resistance.

  • PDF

증점제를 사용한 고유동콘크리트의 건조수축 및 중성화에 관한 연구 (A Study on the Drying Shrinkage and Carbonation High Flowing Concrete using Viscosity Agent)

  • 권영진
    • 한국건축시공학회지
    • /
    • 제3권3호
    • /
    • pp.121-126
    • /
    • 2003
  • This study investigated about several mix factors came up to drying shrinkage and carbonation of high flowing concrete using viscosity. The results are as follows; Drying shrinkage ratio of high flowing concrete using viscosity showed higher for early age, but lower than normal concrete as long age. Also, drying shrinkage ratio and reduction ratio of mass showed higher and relative dynamic modulus of elasticty showed lower as W/C was higher generally. And in case of high flowing concrete using viscosity, carbonation wasn't confirmed without the kinds of cement and viscosity except 50C.

고성능 콘크리트 개발에 관한 실험적 연구(제2보, 초유동 콘크리트의 기초물성) (Experimental Study on the Development of High-Performance Concrete (Properties of Super-flowing Concrete))

  • 조일호;한정호;정재동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.51-56
    • /
    • 1993
  • This is a part a study on the development of High-Performance Concrete ; about experimental results from several test methods to estimate workability in fresh concrete and influences of concrete mix design that affects properties of super-flowing concrete. Super-flowing concrete can be filled in a formwork without any vibration because of its excellent workability of passing narrow space and filling complicated shaped mold, new test methods should be used to estimate the workability and rhelogy in super-flowing concrete instead of slump test method in conventional concrete.

  • PDF

고유동 콘크리트의 응결특성과 압축강도 발현 (Setting and Compressive Strength Development of Hihg Flowing Concrete)

  • 권영진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.8-13
    • /
    • 1995
  • High flowing concrete has been made using a combination of different cementitious material. The use of supplementary cementitious material like ground granulated slag is not only interesting from an economical point of view but also from a mechanical and rheological point of view. In the case of high strength concrete, relation between the maturity and compressive strength development of high strength concrete is aproximated by appling gompertz curve and suggested new estimating method. It is the aim of this study to analysis the effect of different types of mineral fine power on the setting and compressive strength development of high flowing concrete.

  • PDF

고유동 콘크리트의 품질변동 요인에 관한 연구 (A Study on the factors of Quality variation for High Flowing Concrete in Site)

  • 권영호;이현호;이화진;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.743-746
    • /
    • 2004
  • This research investigates experimentally an effect on the properties of the high flowing concrete according to variations of concrete materials and site conditions. Variations of sensitivity test are selected items as followings; (1)Concrete temperature, (2)Unit water(Surface moisture of fine aggregate), (3)Fineness modulus of fine aggregate, (4)Addition ratio of high-range water reducing agent. And fresh conditions of the high flowing concrete should be satisfied with required range including slump flow$(65{\pm}5cm)$, 50cm reaching time of slump flow$(4\~10sec)$, V-box flowing time$(10\~20sec)$, U-box height(min.300mm) and air content$(4{\pm}1\%)$. As results of sensitivity test, material variations and site conditions should be satisfied with the range as followings; (1)Concrete temperature is $10\~20^{\circ}C$ (below $30^{\circ}C$), (2)Surface moisture of fine aggregate is within ${\pm}0.6\%$, (3)Fineness modulus of fine aggregate is $2.6{\pm}0.2$ and (4)addition ratio of high range water reducing agent is within $1\%$ considered flow-ability, self-compaction and segregation resistance of the high flowing concrete.

  • PDF

시공성 향상을 위한 고유동 콘크리트 배합모델 개발에 관한 실험적 연구

  • 손유신;윤영수;송영철;우상균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.66-71
    • /
    • 2000
  • Recently, great efforts and investment have been made in order to achieve economical production by applying new methods like minimization of man-power into construction field. Therefore in this study, we have been focused on the development and practical using of high of high flowing concrete with fly ash, superplasticizer and viscocity agent, also we find out the optimum mix proportions to accomplish good wuality high flowing concrete. The results of this study show that high flowing concrete with the ratio of fly ash replacement of 20%, viscosity agent of 300g/㎥ and superplsticizer 2.0%(C$\times$%) in W/B of 35, 45% has better performance than the high flowing concrete without fly ash replacement

  • PDF

A Study on the High-Flowing Concrete with Low Unit Weight of Cement

  • Si Woo Lee;Hong Shik Choi;Sang Chel Kim;Gweon Heo
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.318-321
    • /
    • 2000
  • Most compressive strengths commonly used in the construction field are in a range of 240 to 300 kgf/$\textrm{cm}^2$ at 28 days. To get this rage of strengths, however, high-flowing concrete requires cementitious binders more than 400 to 450 kg/$\textrm{cm}^2$ for preventing segregation and sedimentation of aggregates. This amount of cementitious binder generates a large emission of excessive hydration heat, which may consequently induce harmful cracks in concrete structure. In order to reduce excessive hydration heat, thus, this paper aims at fabricating a high-flowing concrete under the condition that cement content is kept as low as 350kg/$\textrm{cm}^3$ by using viscose agents. In a parametric study, effects of cement types such as a ternary blended cement and Type V on he physical characteristics of high-flowing concrete were evaluated. In addition, the influence of viscosity was also investigated by applying two different viscose agents, one in a range of 6,000 to 10,000 cps and the others of 10,000 to 14,000 cps. In terms of chemical admixtures used in concrete mixture, the superplasticizer was Sulfonated Melamine-Formaldehyde Condensate with about 30,000 of molecular weight, and main component of viscose agent was HPMC (Hydroxy Propyl Methyl Cellulose). Slump flow was fixed at 50cm with different dosages of superplasticizer in weight.

  • PDF

굵은골재 체적에 따른 고유동콘크리트의 유동특성에 관한 실험적 연구 (The Experience Study on the Floating Properties of High Flow Concrete on volum of Coarse Aggregate used Admixture)

  • 최성우;김호수;백철우;반성수;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.751-754
    • /
    • 2004
  • There are many factors that affect on the flowing properties of high flowing concrete(HFC), which are fluidity, compactibility, non-segregation ability and fillingability. And because the aggregate which is one of the factors occupies high volume in concrete, it has a much effect on the properties of high flowing concrete according to its size, quality and quantity etc. This is an experimental study to analyze the effect of admixture and volume of coarse aggregate in concrete on the flowing properties of high flowing concrete. For this purpose, the kinds of admixture are fly-ash and blast furnace slag. Also volume of coarse aggregate in concrete are 280, 290, 300, 310, 320 $(\ell/m^3)$. The test of flowablity properties is slump-flow, Air content, V-lot, L-Flow. According to test results, it was found that the compactibility of HFC is more superior to use blast furnace slag than other, and according .to kind of admixture, most compatible volume of coarse are different. Also when used blast furnace slag, the volume of coarse are increased than used fly-ash.

  • PDF