• 제목/요약/키워드: high-$T_C$ SQUID

검색결과 45건 처리시간 0.019초

High $T_c$ SQUID system for biological immunoassays

  • Enpuku, K.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.7-7
    • /
    • 2000
  • A high $T_c$ SQUID system is developed for the application to biological immunoassay. In this application, magnetic nanoparticles are used as magnetic markers to perform immunoassay, i.e., to detect binding reaction between an antigen and its antibody. The antibody is labeled with ${\gamma}-Fe_2O_3\;(or\;Fe_3O_4)$ nanoparticles, and the binding reaction can be magnetically detected by measuring the magnetic field from the nanoparticles. Design and set up of the system is described. The system consists of (1) SQUID magnetometer or gradiometer made of 30-deg. bicrystal junctions, (2) field and compensation coils to apply the magnetic field of about 1 mT, (3) special Dewar to realize a 2 mm-distance between the SQUID and the sample, (4) two layers of cylindrical shielding to reduce the extemal magnetic noise to about 1/100, and (5) an electric slider to move the sample with a speed of 10 mm/sec. The sensitivity of the system is studied in terms of detectable magnetic flux. For the measurement bandwidth from 0.2 Hz to 10 Hz, minimum-detectable amplitude of the magnetic flux is $0.8\;m\;{\Phi}_o$ and $0.25\;m{\Phi}_o$ for the magnetometer and the gradiometer, respectively, when the magnetic field of 1 mT is applied. The difference between them is due to the residual environmental noise, and the applied magnetic field does not increase the system noise. The corresponding weight of the magnetic markers is 1 ng and 310 pg, respectively. An experiment is also conducted to measure antigen-antibody reaction with the present system. It is shown that the sensitivity of the present system is 10 times better than that of the conventional method using an optical marker. A one order of magnitude improvement of sensitivity will be realized by the sophistication of the present system.

  • PDF

단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작 (Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

SQUID 센서 기반의 극저자장 자기공명 장치를 위한 사전자화코일 전류구동장치 개발 (Development of Prepolarization Coil Current Driver in SQUID Sensor-based Ultra Low-field Magnetic Resonance Apparatuses)

  • 황성민;김기웅;강찬석;이성주;이용호
    • Progress in Superconductivity
    • /
    • 제13권2호
    • /
    • pp.105-110
    • /
    • 2011
  • SQUID sensor-based ultra low-field magnetic resonance apparatus with ${\mu}T$-level measurement field requires a strong prepolarization magnetic field ($B_p$) to magnetize its sample and obtain magnetic resonance signal with a high signal-to-noise ratio. This $B_p$ needs to be ramped down very quickly so that it does not interfere with signal acquisition which must take place before the sample magnetization relaxes off. A MOSFET switch-based $B_p$ coil driver has current ramp-down time ($t_{rd}$) that increases with $B_p$ current, which makes it unsuitable for driving high-field $B_p$ coil made of superconducting material. An energy cycling-type current driver has been developed for such a coil. This driver contains a storage capacitor inside a switch in IGBT-diode bridge configuration, which can manipulate how the capacitor is connected between the $B_p$ coil and its current source. The implemented circuit with 1.2 kV-tolerant devices was capable of driving 32 A current into a thick copper-wire solenoid $B_p$ coil with a 182 mm inner diameter, 0.23 H inductance, and 5.4 mT/A magnetic field-to-current ratio. The measured trd was 7.6 ms with a 160 ${\mu}F$ storage capacitor. trd was dependent only on the inductance of the coil and the capacitance of the driver capacitor. This driver is scalable to significantly higher current of superconducting $B_p$ coils without the $t_{rd}$ becoming unacceptably long with higher $B_p$ current.