• 제목/요약/키워드: high wear resistance

검색결과 561건 처리시간 0.039초

수복재료에 대합되는 의치용 레진치의 마모저항성 비교 (COMPARISON OF WEAR RESISTANCE AMONG RESIN DENTURE TEETH OPPOSING VAR10US RESTORATIVE MATERIALS)

  • 이철영;정문규
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.313-327
    • /
    • 1999
  • The aim of this study was to compare wear resistance of resin denture teeth opposing various restorative materials. The wear resistance of conventional acrylic resin teeth(Trubyte Biotone) and three high-strength resin teeth(Bioform IPN, Endura, SR-Orthosit-PE) opposing different restorative materials(gold alloys, dental porcelain, composite resin) was compared. Wear tests were conducted with a sliding-induced wear testing apparatus which applied 100,000 strokes to the specimen in a mesio-distal direction under conditions of 100 stroke/min and constant loading of 1Kgf/tooth. Wear resistance of the resin denture teeth was evaluated by the following criteria : 1) wear depth, 2) weight loss, and 3) SEM observation. Results were as follows. 1. When opposed to gold alloys and composite resin, high-strength resin teeth showed superior wear resistance compared to acrylic resin teeth. But, in cases opposing dental porcelain, differences between the wear of the high-strength and acrylic resin teeth were not statistically significant (p<0.05). 2. When comparing wear resistance among high-strength resin teeth, opposing gold alloys, Endura was slightly more resistant and while in cases opposing dental porcelain, SR-Orthosit-PE was showed to be slightly resistant(p<0.05). 3. The wear of high-strength resin teeth was greater by 5 to 7 times when opposing porcelain and 2 to 3 times when opposing composite resin compared to gold alloys(p<0.05). 4. SEM observations of the wear surface showed that wear of resin teeth opposing gold alloys is a fatigue type of wear and wear of resin teeth opposing dental porcelain is fatigue and abrasion type of wear. Trubyte Biotone showed more severe fatigue type of wear than high-strength resin teeth. In conclusion, the use of dental porcelain should seriously be considered as restorative material in cases opposing resin denture teeth and improvement seems to be needed on resin teeth in the areas of wear resistance.

  • PDF

Saffil/SiCp을 이용한 금속 복합재료의 상온 마모 거동 (Wear Behavior of Saffil/SiCp reinforced Metal Matrix Composites at the room temperature)

  • 조종인;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.46-49
    • /
    • 2003
  • Aluminum based metal matrix composites(MMCs) are well known for their high specific strength, stiffness and hardness. They are gaining further importance because of their high wear resistance. In this study, Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15% and Al/Saffil-5%/SiC(particle type)-15% hybird MMCs' wear behavior were characterized by the pin-on-disk test under various normal load The superior wear resistance was exhibited at Al/Saffil-5%/SiC(particle type)-15% MMCs. And this MMCs' predominant wear mechanism is subsurface cracking in the low load wear regime. Others(Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15%) showed the similar wear resistance with each other at the same test condition. In the low load & room temperature condition, the wear resistance was improved due to the high hardness of the ceramic reinforcements. As the test load increased, the wear properties were governed by the wear properties of matrix.

  • PDF

고주파열처리 SM53C강의 기계적 성질에 관한 연구 (A Study on Mechanical Property of SM53C Steel by High Frequency Induction Hardening)

  • 김황수;김정현
    • 한국기계가공학회지
    • /
    • 제9권6호
    • /
    • pp.7-15
    • /
    • 2010
  • Recently, with the high performance and efficiency of machine, there have been required the multi-functions in various machine parts, such as the heat resistance, the abrasion resistance and the stress resistance as well as the strength. Fatigue crack growth tests were carried out to investigate the fatigue characteristics of high carbon steel (SM53C) experienced by high-frequency induction treatment. The Cam nose part of the Automobile's Cam shaft is strongly bumped with rocker arm or valve-lift. Therefore abnormal wear such as unfair wear and early wear occur in the surface. This abnormal wear causes a defect that bad timing open and close actions of the engine valve happen in the combustion chamber so the fuel gas will be combustion imperfect. Therefore, the cam shaft demands high hardness and wear resistance. In this study, high frequency heat treatment has been accomplished while wear test for material SM53C.

0.27C-0.70Ni-1.42Cr-0.20Mo 내마모강의 기계적 성질에 따른 마모특성 (Effects of Mechanical Properties on Wear Resistance of 0.27C-0.70Ni-1.42Cr-0.20Mo Steel)

  • 이용희;한철호;신정호;장병록
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.260-263
    • /
    • 2001
  • Mechanical properties have been accepted to be major factor to improve wear resistance. The effect of mechanical properties on wear resistance of 0.27C-0.70Ni-1.42Cr-0.20Mo steel was studied under various test conditions. It is clear that yield strength, tensile strength, impact value, and hardness are strongly related each other. Wear resistance tests as pin on plate type and dry sand / rubber wheel type proved to be that wear depends on mechanical properties. Microstructures were also observed to make clear the wear properties. At quenching and low temperature tempering, the specimen has a good wear resistance.

  • PDF

고강도 고인성 내마모강의 제조기술 (The Production Technology of High Strength and High Toubhness Wear Resistance Steel)

  • 신정호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2000년도 춘계학술대회논문집
    • /
    • pp.163-166
    • /
    • 2000
  • The production technology of high strength and toughness wear resistance steel involves attempt to application of severe wear parts for the construction machinery. A well balanced alloy content ensures that optimum tensile properties are achieved for the high strength. After high temperature deformation like as rolling or forging it has bainite microstructure and lower yield rato(under 80%) The effectiveness of the research approach is illustrated with experimental results on good steel cleanliness(O2 :12.2 ppm, 0,004% S, 0.008%, P nonmetalic inclusion dT: 0.10) and excellent mechanical properties (TS$\geq$140kgf/mm2 El $\geq$10% IV$\geq$20j/cm2) Therefore this should be wear resistance steel which develops high strength and high toughness without heat treatment

  • PDF

Diesel Engine용 내마모 초경 Tappet 개발 (The development of high wear resistant tappet in diesel engine)

  • 송근철;심동섭;김경운;조정환
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.313-322
    • /
    • 1998
  • Tappet has wear problems like scuffing or pitting because of high Hertzian contact stress by line contact type between cam and tappet. To overcome this wear problems, we developed the high wear resistant tappet. Developed tappet consists of WC base alloyed tip and steel body. These two parts were directly bonded each other at high temperature under vacuum condition. To estimate the wear resistance of tungsten carbide tappet, we perform the scuffing test and engine dynamo test. As the result, tungsten carbide tappet has better wear resistance than conventionally chilled iron tappet.

  • PDF

무가압함침법으로 제조된 입자강화 금속복합재료의 마모특성 (Wear Characteristics of Particulate Reinforced Metal Matrix Composites Fabricated by a Pressureless Metal Infiltration Process)

  • 김재동;정순억;김형진
    • 한국해양공학회지
    • /
    • 제17권1호
    • /
    • pp.55-60
    • /
    • 2003
  • The effect of size and volume fraction of ceramic particles, with sliding velocity on the wear properties were investigated for the metal matrix composites fabricated by the pressureless infiltration process. The metal matrix composites exhibited about 5.5 - 6 times the wear resistance compared with AC8A alloy at high sliding velocity, and by increasing the particle size and decreasing the volume fraction, the wear resistance was improved. The wear resistance of metal matrix composites and AC8A alloy exhibited different aspects. Wear loss of AC8A alloy increased with sliding velocity, linearly : whereas, metal matrix composites indicated more wear loss than AC8A alloy at the slow velocity region. However, a transition point of wear loss was found at the middle velocity region, which shows the minimum wear loss. Further, wear loss at the high velocity region exhibited nearly the same value as the slow velocity region. In terms of wear mechanism, the metal matrix composites generally exhibited abrasive wear at slow to high sliding velocity; however, AC8A alloy showed abrasive wear at low sliding velocity and adhesive and melt wear at high sliding velocity.

무가압함침법으로 제조된 입자강화 금속복합재료의 마모특성 (Wear Characteristics of Particulate Reinforced Metal Matrix Composites Fabricated by Pressureless Metal Infiltration Process)

  • 김재동;정순억;김형진
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.379-384
    • /
    • 2002
  • The effect of size and volume fraction of ceramic particles with sliding velocity on the wear properties were investigated for the metal matrix composites fabricated by pressureless infiltration process. The particulate metal matrix composites exhibited about 5.5 - 6 times of excellent wear resistance compared with AC8A alloy at high sliding velocity, and as increasing the particle size and decreasing the volume fraction the wear resistance was improved. The wear resistance of metal matrix composites and AC8A alloy exhibited different aspects. Wear loss of AC8A alloy increased with sliding velocity linearly. whereas metal matrix composites indicated more wear loss than AC8A alloy at slow velocity region, however a transition point of wear loss was found at middle velocity region which show the minimum wear loss, and wear loss at high velocity region exhibited nearly same value with slow velocity region. In terms of wear mechanism, the metal matrix composites exhibited the abrasive wear at slow to high sliding velocity generally, however AC8A alloy showed abrasive wear at low sliding velocity and adhesive and melt wear at high sliding velocity.

  • PDF

Laser Surface Cladding 고탄소 9CrSi 합금강의 마모 특성 (Wear characteristics of High Carbon 9CrSi Alloy Steel of Laser Surface Cladding)

  • 유능희;강성군
    • 한국재료학회지
    • /
    • 제11권10호
    • /
    • pp.813-819
    • /
    • 2001
  • The microstructure and the distribution of hardness of Co and A1 alloy powder cladding layer in high carbon 9CrSi alloy steel for roll materials cladded by laser surface cladding were investigated. And, for the evaluation of soundness as the roll materials, we examined the wear resistance of the cladding materials with the wear appratus of pin on disc type. The experimental results showed that the microstructure of laser cladding layer was constituted with the clad surface layer, the alloy layer, the heat treatment layer with base metal. The wear resistance of Ni alloy Powder cladding material was superior to that of Co alloy powder cladding material both at the low speed (0.46m/s) and the high speed(0.92m/s). It seemed that the behavior of wear showed the abrasive wear at the early stage and the adhesive wear at the late stage.

  • PDF

고 내마모성 혼합 금속복합재료의 연삭마모 (Abrasive Wear of Hybrid Metal Matrix Composites for High Wear Resistance)

  • 송정일
    • Composites Research
    • /
    • 제12권5호
    • /
    • pp.12-22
    • /
    • 1999
  • 알루미늄 기지 금속복합재료는 비강도, 비강성, 경도가 뛰어난 것으로 널리 알려져 있으며, 높은 마모 저항으로 인해 점점 중요한 재료로 인식되고 있다. 본 연구에서는 AC2B 알루미늄 합금을 기지재로 하고, 알루미나($Al_2O_3$) 및 탄소를 단섬유를 보강재로한 혼합금속복합재료를 제조하였다. 다양한 상대 마모 속도하에서의 연삭 마모 시험을 통해 금속복합재료의 상온 및 고온 마모 거동을 규명하였다. 금속복합재료의 마모 저항은 고속에서 보강재로 인해 향상되었다. 탄소 혼합 금속복합재료의 마모 저항은 탄소의 고체 윤활 효과로 인해 알루미나($Al_2O_3$) 복합재료보다 우수하였으며, 특히 고속에서의 내마모성이 가장 향상되었다. 금속복합재료의 마찰계수는 상온과 고온에서 상대 속도의 변화에도 큰 차이를 보이지 않았다.

  • PDF