• 제목/요약/키워드: high voltage stress

검색결과 551건 처리시간 0.032초

실리콘 폴리머의 내전압 및 절연특성에 관한 연구 (A Study on Dielectric Strength and Insulation Properly of PDMS)

  • 지원영
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.941-946
    • /
    • 2001
  • The fundamental study on HTV silicone for insulation material has been performed. In order to estimate the chemical behavior of siloxane under high voltage, H-NMR, GPC and vinyl contents measurement were used. As an experimental results, after high voltage stress, the molecular weight of siloxane are increased, the vinyl contents of siloxane are decreased. The dielectric strength of vinyl group containing siloxane was lower than only methyl containing siloxane.

  • PDF

The effect of negative bias stress stability in high mobility In-Ga-O TFTs

  • Jo, Kwang-Min;Sung, Sang-Yun;You, Jae-Lok;Kim, Se-Yun;Lee, Joon-Hyung;Kim, Jeong-Joo;Heo, Young-Woo
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.154-154
    • /
    • 2013
  • In this work, we investigated the characteristics and the effects of light on the negative gate bias stress stability (NBS) in high mobility polycrystalline IGO TFTs. IGO TFT showed a high drain current on/off ratio of ${\sim}10^9$, a field-effect mobility of $114cm^2/Vs$, a threshold voltage of -4V, and a subthresholdslpe(SS) of 0.28V/decade from log($I_{DS}$) vs $V_{GS}$. IGO TFTs showed large negative $V_{TH}$ shift(17V) at light power of $5mW/cm^2$ with negative gate bias stress of -10V for 10000seconds, at a fixed drain voltage ($V_{DS}$) of 0.5V.

  • PDF

EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석 (Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP)

  • 권영목;김재철
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.82-93
    • /
    • 2006
  • 본 논문에서는 인버터 구동 고압유도전동기 운전시 스위칭 서지로 인하여 고압유도 전동기 단자에서 발생하는 과도과전압을 저감하기 위한 필터로 인버터 출력단자에서 dv/dt를 저감하는 LCR 필터와 전동기 입력단자에서 케이블과 유도전동기 특성임피던스를 매칭시키는 RC필터에 대한 과도과전압 저감특성을 분석하였다. 이 필터를 고압에 대용량 유도전동기에 적합하도록 EMTP(ElectroMagnetic Transients Program)를 이용하여 모델링 및 케이블 영향에 의한 필터의 과도과전압 저감효과를 전압파형과 고조파 스펙트럼으로 비교분석하고, 이를 토대로 고압 대용량 유도전동기에 사용될 필터를 제시하였다. 인버터 스위칭 서지에 의한 과도과전압은 유도전동기 고정자 권선에 심각한 전압 스트레스를 발생시켜 절연파괴를 일으키는 주요원인이 된다. 이러한 과도과전압을 저감위한 필터설계는 고압유도전동기 시스템에서 필수적인 요소임을 보였다. 또한 제시된 필터는 과도과전압을 효과적으로 저감시키는 것을 EMTP 시뮬레이션을 통하여 입증하였다.

Boost 입력형 능동클램프 Forward ZVS Converter (Characteristics of Boost Input Type Active Clamp Forward ZVS Converter)

  • 오용승;김희준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.386-389
    • /
    • 2002
  • This paper proposes the boost input type active clamp forward ZVS(zero voltage switching) DC-DC converter which can provide high efficiency and improved EMI characteristics. Moreover, it has active clamp circuit for reducing the voltage stress and zero voltage switching technique for minimizing switching loss. The detailed operation principles and the simulation results are presented.

  • PDF

고전압 플라이백 변압기의 과도특성 (Transient Characteristics of High Voltage Flyback Transformer)

  • 임철우;박남주;정세교
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.1-5
    • /
    • 2000
  • This paper deals with the modeling and analysis of the high voltage flyback transformer (HVFBT) often utilized in small-sized high voltage DC power supplies. The parasitic capacitance of th HVFBT with the large turns of the secondary winding causes the undesirable parasitic resonance in the transient state which produces the high current stress and limits the switching frequency of the converter. In order to analyze this phenomenon the equivalent circuit model including the parasitic capacitance is derived and the frequency characteristics are provided. The parasitic resonance in the switching states is also investigated based on this equivalent circuit model. The derived model and analysis is finally validated through the SPICE simulation and experiments.

  • PDF

Reliability Improvement of Titania Ceramics with Surface Flaw Through High Voltage Screening

  • Tanaka, Tomohiro;Kishimoto, Akira
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.386-389
    • /
    • 1999
  • Effect of high voltage screening was examined on mechanical strength of titania ceramics with two different surface roughness. Roughly finished sample showed degraded mechanical strength meaning that the introduced flaw played the role of starting point of mechanical fracture. On such sample, electrically weak parts were eliminated by applying a screening field. Mechanical strength measurement on survived parts revealed that after screening the Weibull plots bended to become a convex curve while plots at high strength region were almost the same. This result means that relatively low mechanical strength parts were eliminated by the electrical method. As a result the Weibull modulus calculated from all the data increased, demonstrating the effect of high voltage screening on titania ceramics containing fracture controlling surface flaws. Roles of the surface flaw such as a common weak spot for both failures are disscussed in relation to the electric field concentration similar to that of mechanical stress.

  • PDF

PDP을 위한 새로운 고성능 에너지 회로 회수 (A new high performance energy-recovery circuit for a plasma display panel)

  • 김태성;한상규;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2005
  • A new high performance energy-recovery circuit (ERC) for a plasma display panel (PDP) is proposed. Two different ERCs are employed on both sides of the PDP, and slow falling and fast rising times are applied. It features a zero voltage switching (ZVS), low electromagnetic interference (EMI), low current stress, high efficiency, no severe voltage notch, reduced sustaining voltage, and high energy-recovery capability.

  • PDF

고압전동기 고정자 권선 절연재료의 미세구조 특성 (Microstructure Property of High Voyage Motor Stator Insulation)

  • 김희동;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.513-517
    • /
    • 1999
  • High voltage motor(rated 6.6kV and 448kw) has failed in the stator endwinding area during normal service. Experiments on microstructure property were conducted using the control and aged insulations, which were drawn out from stator windings of the high voltage motor. The analyses were characterized using stereozoom microscope(SM), scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy(EDS). SM result shows that large voids are present in the interface between turn insulation and groundwall insulation. SEM results indicated that the groundwall insulation is rarely thermal stress. EDS results showed that chemical elements in the high voltage motor stator insulations were Al, Si, O, K and Fe.

  • PDF

Multi-Level Active-Clamp Forward Converter

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.188-189
    • /
    • 2007
  • Conventional active-clamp forward converter shows good performance in low power applications, however it suffers from a high voltage stress of switch and is not suitable for high input voltage applications. To solve this problem, a new multi-level active-clamp forward converter is proposed in this paper. Utilizing low rating switches, the proposed converter features high efficiency and low cost promising for high input voltage applications.

  • PDF

위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구 (A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter)

  • 조한진;이원철;이상석;김태환;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.623-628
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF