Comparative Study on Electrical Discharge and Operational Characteristics of Needle and Wire-Cylinder Corona Chargers

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.520-527
    • /
    • 2006
  • The electrical discharge and operational characteristics of needle and wire-cylinder corona charger based on current measurements for positive and negative coronas were evaluated and compared. A semi-empirical method was used to determine the ion concentrations in the charging zone and at the outlet of both chargers. Results from experimental investigation revealed that magnitudes of the charging current from the wire-cylinder charger were approximately 3.5 and 2 times smaller than those from the needle charger for the positive and negative coronas, respectively. The ion number concentrations at the outlet for positive corona of both chargers were higher than fur negative corona at the same voltage. Flow and electric fields in the charging zone of both chargers were also analyzed via numerical computation. Strong electric field strength zone was identified and led to high charging and particle deposition. Effect of particle deposition on the evolution of discharge current was presented. It was shown that ions loss inside the wire-cylinder charger was higher than the needle charger The particle deposited on the corona electrodes and on the grounded cylinder caused a great reduction in charging efficiency of both chargers.

Temperature Dependence on the Partial Discharge of Epoxy Molding Ignition Coil According to Applied Voltage (에폭시 성형 점화코일의 인가전압에 따른 부분 방전 온도 의존성)

  • Shin, Jong-Yeol;Hong, Jin-Woong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.85-91
    • /
    • 2015
  • A gasoline engine automobile uses high voltage generation of the ignition coil, igniting and burning mixed fuel in the combustion chamber, which drives the engine. When the electronic control unit intermits a current supplied to the power transistor, counter electromotive force with a low voltage is generated by self induction action in the ignition primary coil and a high voltage is induced by mutual induction action with the primary ignition coil in the second ignition coil. The high voltage is supplied to the ignition plug in the combustion chamber, causing a spark, igniting the compressed mixed fuel. If a very small defect occurs inside the insulating material when a voltage is applied in said ignition coil, the performance of the insulation material will get worse and breakdown by a partial discharge of corona discharge. Thus, in this experiment, we are to contribute to improve the performance and ensure the reliability of the ignition coil by investigating partial discharge characteristics according to the change of voltage and temperature when a voltage is applied to the specimen of the epoxy molding ignition coil.

Corona generated Radio Interference of the 750 kV AC Bundle Conductors in Sandy and Dusty Weather Condition in the High Altitude Area

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Wan, Bao-Quan;Pei, Chun-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1704-1711
    • /
    • 2014
  • Sandy and dusty weather condition often occurs in the high altitude areas of China, which may greatly influence the corona generated radio interference (RI) characteristics of the bundle conductors of 750 kV AC power transmission lines. Corona generated RI of the conductors of the 750 kV AC power transmission lines used in practice is measured by EMI receiver with a coupling circuit and a coupling capacitor connected between the high voltage side and the earth side in fine and sandy and dusty condition. The measuring frequency is 0.5 MHz, and the quasi-peak detection is used. RI excitation function is calculated based on the corona RI current measured by the EMI receiver. Corona generated RI characteristics were analyzed from sand concentration and sand particle size. The test result shows that the corona generated RI excitation function is influenced by the sandy and dusty condition. Corona discharge of the conductors is more serious in sandy and dusty condition with an ultraviolet (UV) detector. Corona generated RI excitation function increases with the increase of sand concentration and also increases with the increase of particle size.

Corona Discharge In GIS Initiated by Free Conducting Particles (자유이물에 의한 GIS 내부 코로나특성 연구)

  • Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1801-1803
    • /
    • 1997
  • The Gas Insulated Switchgear(GIS) has made it an indispensible part of power transmission network. In order that the GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, the corona discharge in GIS initiated by the free conducting particles was discribed through laboratorial experiment The magnitude of the corona discharge voltage was measured using current measuring method by the impedance. The purpose of this experiment is to get fundamental data which is essential to develop GIS diagnosis technology.

  • PDF

Development and Its Characterization of Earth Plate for Early Streamer Discharge (조기방전용 접지판의 개발 및 특성)

  • Choi, Sang-Won;Her, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

Analysis of the Ultrasonic Signals by the Partial Discharge and Noises from the Transformer (변압기 부분방전과 노이즈에 의한 초음파 신호 분석)

  • Gwon, Dong-Jin;Jeong, Gil-Jo;Jin, Sang-Beom;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.354-360
    • /
    • 2002
  • The partial discharge detecting method using the ultrasonic technique has been investigated to monitor the insulation ageing of a transformer. However, the result of the studies on the ultrasonic technique for detecting of partial discharge in the operating transformer is not enough yet to utilize. This paper presents the analysis of the ultrasonic signals due to the partial discharge in a model transformer and the corona in air at a shielded high voltage room. In addition, the ultrasonic signals due to the vibration from the core, operation of the cooling pump, the fan and the OLTC at the 345㎸ power transformer, were analyzed and corona noise from overhead transmission line in 345㎸ substation were measured to remove the electrical and mechanical noises from the transformer. Furthermore, ultrasonic signal due to the partial discharge in the 154㎸ power transformer with in $C_2$$H_2$ gas warning condition was measured. The inside of the transformer was examined with care. which confirms the existence of the partial discharge source.

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air (코로나방전에 의한 공중(空中)초음파 신호 특성)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.38-46
    • /
    • 1999
  • Measurerments of ultrasonic signals caused by corona discharges were perforrred by using an ultrasonic meeasurerment technique to analyze the deve1qxrent states of coronas in a high-voltage power apparatus. We also examined the relationship between discharge magnitude and ultrasonic pulse number to diagnose the deterioration of electrical insulation by corona discharges. From these results, it was found that ultrasonic signals due to corona discharges can be firstly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of ultrasonic signals was closely related to the current pulses by the corona discharges when ac voltages were gradually raised, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, tirre-delaying and directivity charocteristics of ultrasonic signals propagated to air by using ultrasonic oscillation and receiving systems are feJXlrt.ed as a basic data of ultrasonic measurements in out-door HV apparatus.aratus.

  • PDF