• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.036 seconds

Fabrication and Characteristics of High Brightness White Emission Electroluminescent Device (고휘도 백색방출 전계발광소자의 제작 및 특성)

  • Bae, Seung-Choon;Kim, Jeong-Hwan;Park, Sung-Kun;Kwun, Sung-Yul;Kim, Woo-Hyun;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • White emission thin film electroluminescent device was fabricated using ZnS for phosphor layer and BST ferroelectric thin film for insulating layer. For fabrication conditions of BST thin film, stoichiometry of target was $Ba_{0.5}Sr_{0.5}TiO_3$, substrate temperature was $400^{\circ}C$, working pressure was 30 mTorr, and A:$O_2$ ratio was 9:1. At this time, dielectric constant was 209 at 1kHz frequency. For phosphor layer ZnS:Mn, ZnS:Tb, and ZnS:Ag were used. Mixing rates of activators were respectively 0.8, 0.8, and 1 wt%. Total thickness of phosphor tapers was 500 nm, thickness of lower insulating layer was 200 nm, and thickness of upper insulating layer was 400 nm. In this conditions, luminescence threshold voltage of thin film electroluminescent device was $95\;V_{rms}$, maximum brightness was $3,000\;cd/m^2$ at $150\;V_{rms}$. Luminescence spectrum peak was observed at region of blue(450 nm), green(550 nm), and red(600 nm).

  • PDF

A Qualitive Research of N2, O2 Permeation Property in PMDA/ MDA- Phenylene Diamine Copolyimide (PMDA/MDA-Phenylene diamine 계열의 공중합체막에서의 산소, 질소 투과 특성의 정성적 고찰)

  • Lee, Kyung-Rok;Na, Seong-Sun;Kim, Jong-Pyo;Min, Byoung-Ryul
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.13-19
    • /
    • 1998
  • Copolyimide membranes of different chemical structure based on pyromellitic dianhydride (PMDA)/methylendianiline(MDA) were prepared by varying their chemical compositions with adding meta-phenylendiamine (MPD), para- phenylendiamine (PPD), 2,4,6- trimethyl-1,3-phenylenediamine(TriMeMPD) as a co-monomer. The $N_2$ and $O_2$ permeation properties are qualitatively correlated to specific free volume and intersegmental distance of membrane. The partial replacement of MDA with MPD or PPD caused in the PMDA/MDA based membranes increase in density, and decrease in free volume, d-spacing, consequently resulted in decreased permeability coefficient. In the case of TriMeMPD, opposite results were observed. In all membranes, the permeability coefficients were pressure independent, and membranes which have high permeability coefficient showed low $N_2/O_2$ ideal separation factor as an usual manner. The permeability coefficient also increased with temperature and $N_2/O_2$ ideal separation factor decreased. The increase ratio of the $N_2$ permeability coefficient was larger than that of $O_2$.

  • PDF

A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers (테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구)

  • Chio, Ho Chun;Hong, Jwa Ryung;Lee, Gye Young;Kim, Doo Ho;Park, Chung Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

Antimicrobial Activity of Ginger(Zingiber officinale Roscoe) Oleoresin by Supercritical Fluid Extraction (초임계유체 추출에 의한 생강(Zingiber officinale Roscoe) Oleoresin의 항균활성)

  • Lee, Myung-Hee;Lee, Kyoung-Hae;Kim, Kyung-Tack;Kim, Sung-Soo
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.109-116
    • /
    • 2012
  • The study indicated that antimicrobial activity about gram positive and gram negative bacteria of ginger-oleoresin(GO) extract with the condition of ethanol and supercritical fluid extractions. As the concentration of extraction increases, the clear zone of GO ethanol extract also increased dependently. This led the antimicrobial activity of gram positive bacteria to take bigger place than gram negative bacteria especially in Listeria monocytogenes. There was a high antimicrobial activity in E-III treatment where the ratio of the ginger powder extract to ethanol extraction was 1:6. It was quite effective to treat the antimicrobial activity of GO ethanol extract under $80^{\circ}C$ and there was not big difference in the intervals which were the extraction time - 1 to 7 hours. The antimicrobial activity of supercritical fluid extract seemed to take the biggest place in Listeria monocytogenes. From the supercritical fluid extract, it was shown the strong ability of antimicrobial activity in the condition with 100 bar $35^{\circ}C$, 250 bar $35^{\circ}C$ and 250 bar $65^{\circ}C$. Furthermore, according to the case of solvent extract, there was not any significant difference in the antimicrobial activity with condition of extraction. However, there was significant antimicrobial activity in E-III treatment of 100 bar and 500 bar of extraction pressure, and $35^{\circ}C$ and $65^{\circ}C$ of extraction temperature.

Survey of Beauvericin Contamination in Korean Grains by HPLC and the Production of Beauvericin and Enniatin Derivatives by Fusarium oxysporum KFCC 11363P (한국산 곡류의 Becuvericin의 오염도 조사 및 Becuvericin과 Enniatin 유도체 생성조건)

  • Song, Hyuk_hwan;Lee, Hee-Seok;Lee, Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • The productions of beauvericin and enniatins H, I, and MK1688 by Fusarium oxysporum KFCC 11363P were investigated on rice substrate at four temperatures (15, 20, 25, and $30^{\circ}C$) and three moisture contents (10, 20, and 40%). The largest amount of beauvericin ($718.0\;{\mu}g/g$) was produced at $25^{\circ}C$, and maximum levels of enniatin H ($781.9\;{\mu}g/g$), I ($725.8\;{\mu}g/g$), and MK1688 ($425.8\;{\mu}g/g$) were measured by high pressure liquid chromatography (HPLC) at the same temperature. The optimal moisture content for the production of beauvericin and enniatins H, I, and MK1688 was 40%, and the trace amounts of these toxins were observed at 10% moisture content. Sixty five grain samples (n=65) were tested for the monitoring of beauvericin. This mycotoxin was detected in six grain samples including three maize, two barley, and one wheat samples. The highest contamination level of beauvericin was observed in maize sample ($0.23\;{\mu}g/g$).

Studies on the Recovery of Triglyceride from Used Shortening by Supercritical Fluid Extraction (초임계유체 추출에 의한 폐식용유의 재활용에 대한 기초연구)

  • Han, Byung-Seok;Yoon, Jung-Ro;Kwon, Young-An;Jung, Mun-Yhung;Kim, Kong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1300-1307
    • /
    • 1999
  • Supercritical fluid extraction was applied to recycling triglyceride from used shortening. Used shortening and its fractions were analyzed with high performance size exclusion chromatography for their composition in triglycerides, polymer and low molecular weight compounds. Conjugated diene value and color of the fractions were also measured with a UV spectrophotometer and a colorimeter, respectively. Pressure and temperature ranges employed were $15{\sim}30$ MPa and $40{\sim}60^{\circ}C$, respectively. Concentration of fat in supercritical (SC) $CO_2$ ranged from $0.3\;X\;10^{-3}{\sim}7.4\;X10^{-3}(g\;fat/g\;CO_2)$. An exponential relation between concentration of fat in SC $CO_2$ and density was observed. Color of the extracts was light yellow which was very close to that of the fresh shortening. Low molecular weight compounds were preferentially concentrated in the initial fraction, while polymer was extracted in the final fraction. Conjugated diene value of the initial fractions was clearly lower than that of feed. It increased sharply as the polymer content in the fraction became significantly large.

  • PDF

Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation (PVC필터에 채취된 절삭유의 손실에 관한 연구)

  • Park, Dong-Uk;Ha, Kwon-Chul
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.451-457
    • /
    • 2001
  • Because liquids with high molecular weight such as mineral oil have low vapor pressure at room temperature, it is generally thought to be difficult to lose them to evaporation. However, when they are dispersed into air in small droplets during application in machining processes, their surface area becomes considerably higher. To determine the potential for metalworking fluids (MWF) filter losses, MWF mist was generated and collected on polyvinyl chloride (PVC) filters in test chamber. After collected MWF was exposed to clean air during designated period (range 10~240 minutes) and the filters were desiccated, losses were evaluated. As duration of clean air passing through PVC filter increased, loss of MWF gradually increased. MWF lost after 10 minutes ranged form 12.4 % to 21.8 % of the original loading mass, on average 53.3 % of the total loss. These results indicate that significant mass of MWF collected on PVC filters can be lost at the beginning of air sampling. Loss of MWF collected on PVC filter also occurred during desiccation without active airflow. In multiple regression to identify which factors influence the loss of MWF collected on PVC filter, both duration of air passing through PVC filter and MWF age (fresh vs. used) were significant predictor (p=0.0001). Therefore, workers' exposure to MWF measured method 0500, may underestimate true concentration. Further study is needed to develop a new method to quantify the workers' exposure to airborne MWF mist accurately.

  • PDF

Separation Characteristics of $CH_4/CO_2$ Mixed Gas by Polyamide Composite Membrane (Polyamide 복합막을 이용한 메탄/이산화탄소 혼합기체의 분리 특성)

  • Lee, Jae-Hwa;Lee, Geon-Ho;Choi, Kyung-Seok;Poudel, Jeeban;Kim, Soo-Ryong;Oh, Sea-Cheon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.478-485
    • /
    • 2012
  • Polymers are widely used as membrane material for performing the separation of various gaseous mixtures due to their attractive permselective properties and high processability. The separation characteristics of $CH_4$ and $CO_2$ mixed gas using polyamide composite membrane has been studied in this work. The sample gas was prepared by mixing pure methane and carbon dioxide. Permeation tests were carried out at different operation conditions. Feed flow rates were varied between 800~1000 $cm^3/min$, and the stage cuts were varied between 50~60%. The gas inlet pressure and the temperature were varied as 6 bar and $30{\sim}70^{\circ}C$, respectively. The effects of the above mentioned parameters were investigated to estimate the permeability of $CH_4$ and $CO_2$, and the selectivity of $CO_2$ was also calculated for all conditions. The Arrhenius plots were also performed to obtaine the activation energies of $CH_4$ and $CO_2$ permeabilities.

Study of Stability and Shelf-life of Red Ginseng Beverage Emulsified by Homogenizer High Pressure (고압균질기로 유화된 홍삼음료의 안정성과 유통기한 변화에 대한 연구)

  • You, Kwan-Mo;Jang, Hyeon-Ho;Lee, Eui-Seok;Park, Jong-Tae;Hong, Soon-Taek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.70-79
    • /
    • 2018
  • This study was carried out to predict the shelf-life of emulsified red ginseng beverage. To investigate the quality changes during the storage, physicochemical properties such as acidity, pH, droplet size, Hunter's color value and sensory evaluation test were measured periodically. It was found that acidity, pH, and droplet sizes were little changed in initial stage. After about 70 days of storage, however, they tended to be changed possibly due to Maillard reaction. From the results of correlation analysis between sensory evaluation results and physicochemical characteristics, a-value was chosen as a quality index of red ginseng emulsions. Using reaction constants at various temperature, the activation energy and the $Q_{10}$ value for the a-value from Arrhenius equation found to be 13.37 kcal/mol, 1.56-2.14, respectively. It could be concluded that the shelf-life of red ginseng emulsions estimated to be 730 days (approximately 2 years) when stored at $20^{\circ}C$.