The Study on the Synthesis of Triazole Derivatives as Energetic Plasticizer (트리아졸 계열의 에너지 가소제 합성 연구)

  • Lee, Woonghee;Kim, Minjun;Park, Youngchul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.31-38
    • /
    • 2016
  • Most of propellants that is used widely in the world release toxic gases such as methane gas and carbon dioxide during combustion which are noxious to the environment. This study established a synthetic process of a high nitrogen containing derivative of triazole, 4,5-bis(azidomethyl)-methyl-1,2,3-triazole (DAMTR), which can be applied as energetic plasticizer to environmental concerns. Also, the compound was characterized by NMR, IR spectroscopy, and physical properties such as glass transition temperature, melting point, decomposition temperature, density, impact sensitivity, viscosity and volatility were measured. In addition, the heats of formation (${\Delta}H_f$) and detonation properties (pressure and velocity) of DAMTR were calculated using Gaussian 09 and EXPLO5 programs.

Analysis of Hydrogen Fuel for Existing Domestic Boilers and New Heat Recovery Boilers with Water Spray (기존 가정용 보일러 및 신형 물분사 폐열회수 보일러에 대한 수소 연료의 평가)

  • LEE, CHANG-EON;KIM, DAEHOON;PARK, TAEJOON;MOON, SEOKSU
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.2
    • /
    • pp.210-222
    • /
    • 2020
  • Hydrogen is evaluated as one of new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is free from CO2, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. This study investigates the differences in operating characteristics and its problems to be modified when the hydrogen is used as fuel for existing domestic boilers and new heat recover boilers with water spray. When the hydrogen is used in domestic boilers, the efficiency is about 6-7% lower than methane due to higher partial vapor pressure in the exhaust gas at usual operating conditions above 60℃ in combustion chamber outlet temperature. On the other hand, the heat recovery boiler with water spray (HR-B/WS-X) is expected to achieve up to 95% efficiency, which is 12% more efficient than conventional boilers. It can also significantly reduce NOx emission by lowering the flame temperature.

Experimental Research on Effects of Water Sprayed Curtain On Anti-diffusion of Fire Gases in Case of Tunnel Fire (터널 화재시 물분무노즐에 의해 형성되는 제연수막의 연기층 확산방지성능에 관한 실험적 연구)

  • Park, Hyung-Joo;Choi, Young-Sang;Jee, Nam-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2004
  • In case of a fire in road or railway tunnel it is always necessary to keep the escape condition as good as possible. Most of the victims of major fires in tunnels are because they couldn't leave the tunnel in time and were trapped by smoke, or rescue teams couldn't reach the place of the accident due to low visibility and high temperature. In spring 2003 a comprehensive field experiment was undertaken in a large scaled tunnel in Youngin City to test the effectiveness of a new water spray curtain system, designed to the air qualify inside of a tunnel in case of fire during passenger's escape to safe routes, In order to control the smoke propagation, fixed water sprayed nozzles were used to make water curtain system, which can be installed or hanging water piping line below ceiling. The experiment was accompanied by an extensive measurement campaign in order to measure temperature dropping effect and flow conditions as well as CO concentration for various water sprayed curtains produced by sprinkler heads or water spray nozzle. Eventually comparison analysis were undertaken to investigate the performance of water curtains under fixed water pressure. Therefore most effective water curtain system was presented on the basis of water droplet size in long tunnel.

Simulation for Performance Analysis of a Grain Cooler (곡물냉각기의 성능해석을 위한 시뮬레이션)

  • 박진호;정종훈
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.449-460
    • /
    • 2001
  • This study was carried out to develop a simulation model with EES(Engineering equation solver) for analyzing the performance of a grain cooler. In order to validate the developed simulation model, several main factors which have affected on the performance of the gain cooler were investigated through experiments. A simulation model was developed in the standard vapor compression cycle, and then this model was modified considering irreversibe factors so that the developed alternate model could predict the actual cycle of a grain cooler. The compressor efficiency in vapor compression cycle considering irreversibility much affected on the coefficient of performance(COP). The COP in the standard vapor compression cycle model was greatly as high as about 6.50, but the COP in an alternative model considering irreversibility was as low as about 3.27. As a result of comparison between the actual cycle and the vapor compression cycle considering irreversibility, the difference of pressure at compressor outlet(inlet) was a little by about 48kPa (8.8kPa), the temperatures of refrigerant at main parts of the grain cooler were similar. and the temperature of chilled air was about 8$\^{C}$ in both. The model considering irreversibility could predict performance of the grain cooler. The theoretical period required to chill grain of 1,383kg from the initial temperature 24$\^{C}$ to below 11$\^{C}$ was about 55 hours 30 minutes, and the actual period required in a grain bin was about 58 hours. The difference between the predicted and an actual period was about 2 hours 30 minutes. The cooling performance predicted by the developed model could well estimate the cooling period required to chill the grain.

  • PDF

Determination of Water Content in Compacted Bentonite Using a Hygrometer and Its Application (습도계를 이용한 압축벤토나이트 내 함수율 결정 및 적용)

  • Lee, Jae-Owan;Cho, Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.101-107
    • /
    • 2009
  • Investigation of resaturation and thermal-hydro-mechanical behavior for the buffer of a repository requires measuring the water content of compacted bentonite. This study investigated the relative humidity of compacted bentonites using a humidity sensor (Vaisala HMT 334) applicable under high temperature and pressure, and then conducted a multi-regression analysis based on the measured results to determine relationships among the water content, relative humidity, and temperature. The relationships for the compacted bentonites with the dry densities of 1,500 $kg/m^3$ and 1,600 $kg/m^3$ were expressed as ${\omega}=0.196RH-0.029T+1.391({r^2=0.96)}$ and ${\omega}=0.199RH-0.029T+2.596({r^2=0.98)}$, respectively. These were then used to interpret the resaturation of bentonite blocks in the KENTEX test.

  • PDF

A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge (슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The performance of the small scale cyclone incinerate system (100kg/hr) to process the sewage sludge containing high moisture is evaluated. The incinerate system design is based on properties of the domestic sewage sludge. The combustion characteristics of the incinerate system is tested and analyzed with the various operation conditions of the moisture level, the sludge feed rate and the auxiliary fuel feed rate. The pressure loss of the whole system is appeared relatively small of 700mmAq under the normal operating condition and the temperature distribution of the incinerator internal combustion is maintained less than 1000C. Auxiliary fuel of 4.7 1/hr is required to incinerate 100kg sludge which include 87% moisture. Because the inside temperature of the incinerator is maintained less than $1000^{\circ}C$, it is predicted that the most NOx measured is produced not from the heat during the combustion process but from the oxidation of the N ingredient in the sludge. From the component analysis of ash, the organic matter is not entirely detected. Accordingly, it is estimated that the complete combustion has been accomplished in the incinerator.

  • PDF

A Study on Performance of Initial Blowoff Flow for a Fuel Pump with Various Temperature and Composition Condition in LPG Engine (자동차용 LPG 펌프의 온도 및 연료조성에 따른 초기토출성능에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Up;Choi, Kyo-Nam
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.12-17
    • /
    • 2008
  • The In recent years, the need for more fuel-efficient and lower-emission vehicles has driven the technical development of alternative fuels such as LPG (Liquefied Petroleum Gas) which is able to meet the limits of better emission levels without many modifications to current engine design. LPG has a high vapor pressure and lower viscosity and surface tension than diesel and gasoline fuels. These different fuel characteristics make it difficult to directly apply the conventional gasoline or diesel fuel pump. In this study, experiments are performed to get initial performance and efficiency of the fuel pump under different condition of the temperature and composition of fuel. The characteristics of vane type fuel pump were investigated to access the applicability on LPLi engine.

  • PDF

Effects of Composition of Metallic Friction Materials on Tribological Characteristics on Sintered Metallic Brake Pads and Low-Alloy Heat-Resistance Steel for Trains (철도차량용 금속계 소결마찰재의 조성에 따른 트라이볼로지 특성)

  • Yang, Yong Joon;Lee, Hi Sung
    • Tribology and Lubricants
    • /
    • v.30 no.6
    • /
    • pp.330-336
    • /
    • 2014
  • Sintered metallic brake pads and low alloy heat resistance steel disks are applied to mechanical brake systems in high energy moving machines that are associated with recently developed 200km/h trains. This has led to the speed-up of conventional urban rapid transit. In this study, we use a lab-scale dynamometer to investigate the effects of the composition of friction materials on the tribological characteristics of sintered metallic brake pads and low alloy heat resistance steel under dry sliding conditions. We conduct test under a continuous pressure of 5.5 MPa at various speeds. To determine the optimal composition of friction materials for 200 km/h train, we test and the evaluate frictional characteristics such as friction coefficients, friction stability, wear rate, and the temperature of friction material, which depend on the relative composition of the Cu-Sn and Fe components. The results clearly demonstrate that the average friction coefficient is lower for all speed conditions, when a large quantity of iron power is added. The specimen of 25 wt% iron powder that was added decreased the wear of the friction materials and the roughness of the disc surface. However when 35 wt% iron powder was added, the disc roughness and the wear rate of friction materials increased By increasing the amount of iron powder, the surface roughness, and temperature of the friction materials increased, so the average friction coefficients decreased. An oxidation layer of $Fe_2O_3$ was formed on both friction surfaces.

Design Point Operating Characteristics of an Oxidizer Rich Preburner (산화제 과잉 예연소기 설계점 운영 특성)

  • Moon, Ilyoon;Moon, Insang;Kang, Sang Hun;Ha, Seong-Up;Lee, Soo Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.4
    • /
    • pp.81-88
    • /
    • 2013
  • It was designed and tested at the design point that an oxidizer rich preburner for a staged combustion liquid rocket engine propelled by kerosene and LOx. The oxidizer rich preburner was designed as some of LOx injected from the mixing head was burned with kerosene and the rest of LOx injected from injection holes in the regenerative cooling chamber was vaporized by combustion gas. The preburner is operated at OF ratio of 60 and combustion pressure of 20 MPa. The Preburner has a honey-comb type mixing head with simplex swirl injectors, a turbulence ring improving combustion stability and uniformity of product gas temperature distribution, and a nozzle simulating the duct. With the combustion test results at the design point, the oxidizer rich preburner showed high combustion stability and uniformity of product gas temperature distribution.

A Study on Derivation of Contact Heat Transfer Coefficient Between Die and Aluminum Billet in High Temperature Compression Process (고온 압축 공정에서 금형과 알루미늄 빌렛의 접촉 열전달 계수 도출에 관한 연구)

  • Jeon, H.W.;Suh, C.H.;Oh, S.G.;Kwon, T.H.;Kang, G.P.;Yook, H.S.
    • Transactions of Materials Processing
    • /
    • v.30 no.3
    • /
    • pp.142-148
    • /
    • 2021
  • In hot forging analysis, the interfacial heat transfer coefficient (IHTC) is a very important factor defining the heat flow between the die and the material. In particular, in the hot forging analysis of aluminum 6xxx series alloy, which are used in automobile parts, differences in load and microstructure occur due to changes in surface temperature according to the IHTC. This IHTC is not a constant value but changes depends on pressure. This study derived the IHTC under low load using aluminum 6082 alloy. An experiment was performed by fabricating a compression die, and a heat transfer analysis was performed based on the experimental data. The heat transfer analysis used DEFORM-2D, a commercial finite element analysis program. To derive the IHTC, heat transfer analysis was performed for the IHTC in the range of 10 to 50 kW/m2℃ at intervals of 10kW/m2℃. The heat transfer analysis results according to the IHTC and the actual experimental values were compared to derive the IHTC of the aluminum 6082 alloy under low load.