• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.032 seconds

Tropical Cyclone Center and Intensity Analysis from GMS-4 TBB data (GMS-4 $T_{BB}$ 자료를 이용한 태풍의 중심 및 강도 분석)

  • 김용상;서애숙;신도식;김동호
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.2
    • /
    • pp.111-125
    • /
    • 1996
  • A forecast technique using GMS-4(Geostationary Meteorological Satellite) infrared images and its $T_{BB}$ (Brightness Temperature) data to determine the tropical cyclone center and to analyze the tropical cyclone intensity has been developed. First, the determination of typhoon center using $T_{BB}$ distribution pattern is practiced by understanding a special feature of central cloud pattern and cloud band which is analyzed with the method of pseudo coloring. Then, to forecast the intensity of tropical cyclone, a relationship between the central pressure (or maximum wind speed) of tropical cyclone and $T_{BB}$ measured by GMS near the tropical cyclone center was investigated. The results showed a correlation with a high lag relationship between central pressures and $T_{BB}$. The mean Tee in the ring of 200~300km apart from the tropical cyclone center showed the best correlation to central pressure of the tropical cyclone after 24hour. From this relationship, a regression equation to forecast the central pressure (or maximum wind speed) was derived.

A Study on the Surface Roughness Behavior of Reactor Vessel Stud Holes in APR1400 Nuclear Power Plants (APR1400 원자로 용기 스터드 홀의 표면거칠기 거동에 관한 연구)

  • Kim, Dong Il;Kim, Chang Hun;Moon, Young Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.62-70
    • /
    • 2019
  • The APR1400 reactor may be operated for a long time under high temperature and pressure conditions, causing damage to the stud holes and causing stud bolts and holes to stick. The present practice is to manually remove the anti-sticking agent and foreign matter remaining in the APR1400 reactor stud hole and to visually check the surface condition of the thread to check the damage status of the threads. In the case of the APR1400 reactor stud holes, manually cleaning the threads increases the risk of radiation exposure and operator's fatigue. To avoid this, the autonomous mobile robot is used to automatically clean the reactor stud holes. The purpose of this study is to optimize the cleaning performance of the mobile robot by looking at the behavior of the surface roughness of the stud surface cleaned by the brush attached to the mobile robot due to changes in brush material, thickness of wire, and rotation speed. A microscopic approach to the surface roughness of the flank is needed to investigate the effects of the newly proposed brush of the autonomous mobile robot on the thread holes. According to this experiment, it is reasonable to use STS brush rather than Carbon one. Optimal operating conditions are derived and the safety of APR1400 reactor stud holes maintenance can be improved.

Hydrodynamics and Solid Circulation Characteristics of Oxygen Carrier for 0.5 MWth Chemical Looping Combustion System (0.5 MWth 케미컬루핑 연소시스템 적용을 위한 산소전달입자의 수력학 특성 및 고체순환 특성)

  • RYU, HO-JUNG;KIM, JUNGHWAN;HWANG, BYUNG WOOK;NAM, HYUNGSEOK;LEE, DOYEON;JO, SUNG-HO;BAEK, JEOM-IN
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.6
    • /
    • pp.635-641
    • /
    • 2018
  • To select the operating condition of 0.5 MWth chemical looping combustion system, minimum fluidization velocity, transition velocity to fast fluidization and solid circulation rate were measured using mass produced new oxygen carrier (N016-R4) which produced by spray drying method for 0.5 MWth chemical looping combustion system. A minimum fluidization velocity decreased as the pressure increased. The measured transition velocity to fast fluidization was 2.0 m/s at ambient temperature and pressure. The measured solid circulation rate increased as the solid control valve opening increased. We could control the solid circulation rate from 26 to $93kg/m^2s$. Based on the measured minimum fluidization velocity and transition velocity to fast fluidization, we choose appropriate operating conditions and demonstrated continuous solid circulation at high pressure condition (5 bar-abs) up to 24 hours.

Performance Evaluation of a Closed-Loop Pressure Retarded Membrane Distillation for Brackish Water Desalination and Power Generation (기수담수화와 전력 생산을 위한 폐루프형 압력 지연식 막 증류 공정의 성능 평가)

  • Cho, Gyu Sang;Lee, Jun-Seo;Park, Kiho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.525-534
    • /
    • 2022
  • In this study, we investigated the applicability and optimal operating strategy of a closed-loop pressure retarded membrane distillation (PRMD) for brackish water desalination. For effective operation with net power generation, high temperature of heat source over 90 ℃ and feed flow rate at 0.6 kg/s are recommended. At 3 g/L of feed concentration, the average permeate flux and net energy density showed 8.04 kg/m2/hr and 2.56 W/m2, respectively. The average permeate flux and net energy density were almost constant in the range of feed concentration from 1 to 3 g/L. Compared to the case with seawater feed, the PRMD with brackish water feed showed higher average permeate flux and net energy density. Thus, PRMD application using brackish water feed can be more effective than that using seawater feed in terms of power generation.

Condensation Heat Transfer of R32 and R454B Inside a Microfin Tube as an Alternative Refrigerant to R410A (R410A 대체냉매 R32와 R454B의 미세핀 관내 응축 열전달)

  • KARAGEORGIS, ANDREAS;HINOPOULOS, GEORGE;KIM, MAN-HOE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.413-418
    • /
    • 2022
  • This paper presents two-phase condensation heat transfer and pressure drop characteristics of R32 and R454B as an alternative refrigerant to R410A in a 9.52 mm OD microfin tube. The test facility has a straight, horizontal test section with an active length of 2.0 m and is cooled by cold water circulated in a surrounding annular space. The heat transfer coefficients of the annular space were obtained using the modified Wilson plot method. Average condensation heat transfer coefficient and pressure drop data are presented at the condensation temperature of 35℃ for the range of mass flux 100-400 kg/m2s. The average condensation heat transfer coefficients of R32 refrigerant are 35-47% higher than R410A at the mass flux considered in the study, while R454B data are similar to R410A. The average pressure drop of R32 and R454B are much higher than R410A and they are 134-224% and 151-215% of R410A, respectively. R32 and R454B have relatively low GWP and high heat transfer characteristics, so they are suitable as alternatives for R410A.

Development and evaluation of women's leggings prototype for improvement of blood circulation through flexible heating surface and gradual compression (점진적 컴프레션 및 유연면상발열을 통한 혈액순환 개선 여성 레깅스 프로토타입 개발 및 평가)

  • Jin Hee Hwang;Yun Ah Lee;Seung Hyun Jee;Sun Hee Kim
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.3
    • /
    • pp.53-67
    • /
    • 2023
  • Blood circulation is one of the most important life support functions of our body. It is essential to maintain healthy blood circulation as problems with blood circulation can lead to numerous diseases and serious complications. This study developed women's leggings with gradual compression and soft surface heating functions to improve blood circulation, and evaluated their performance and wearability. A silicon print pattern was developed to provide gradual compression, and a flexible heating surface coated with MWCNT (multi-walled carbon nanotube) conductive ink was fabricated for comfort and thermal effect. For the design, incision lines and materials were applied in consideration of aesthetic aspects, and design lines and colors were altered using a 3D program. The developed leggings showed that blood circulation can be improved when gradual compression and heating functions are simultaneously applied. Results were confirmed through measurements of clothing pressure, blood flow, and surface temperature. In the subjective wearability evaluation, it was confirmed that wearers felt gradual pressure, and they showed high satisfaction with wearability and design.

Studies on Raw Silk Cohesion for Promotion (생사의 포합향상에 관한 연구)

  • 최병희;김병호;원성희
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.1
    • /
    • pp.37-48
    • /
    • 1973
  • The purpose of this studies is to improve the cohesion of raw silk through various analyses on cocoon drying, cooking, reeling, re-reeling, and on the properties of water. Also we investigated the correlation between silk testing items which we have reached to the following results. 1. Drying of cocoon When cocoons were slowly dried with 100$^{\circ}C$, the results of cohesion became much better. On the other hand, the results were considerably decreased in case the temperature with 115$^{\circ}C$. 2. Cooking of cocoon In case of the cooking of cocoon, we found that the result of cohesion was best with incomplete cooking, that of the control was next, while in over cooking, the results were very low. Also the results of cohesion were much better when using the method of over cooking with sericin arrestive agent than that of incomplete cooking with sericin agglutinating agent. 3. Reeling of cocoon A) When the temperature of reeling bath was 25-45$^{\circ}C$, the results of cohesion test were much better, but at the temperature below 25$^{\circ}C$ or above 45$^{\circ}C$, the results became worse. B) With out the process of croissieur, the results of cohesion were too bad, but in case of croissieur more than 1cm, cohesion became better rapidly. Further more, we understood that the results of cohesion were improving slightly with longer length of croissieur. C) When the velocity of reeling was increased, the results of cohesion also improved. The best results were shown when reeling velocity was 180-220 r.p.m. But when the velocity was increased more than 220 r.p.m., the results of cohesion got worse more or less. D) When the temperature of the drying pipe in reeling machine was raised, the results of cohesion also showed a tendency to improve. 4. Re-reeling A) We could net reach a conclusion as to have correlation between the number of dipping repeat in vacuum tank and the results of cohesion before re-reeling process. B) When we used Seracol 500 as an agglutination protective agent with l/1000 to l/2000 of water, the results of cohesion test were better. C) When we used Pearl-lite as an agglutination protective agent with 1/1000 to 1/2000 of water, the results of cohesion were considerably better. D) We gained tile best results when used Cohesion Improving Chemical, A-80, with 500-1500 times diluted. 1) Results of cohesion was improved when humidity was low or temperature was high in the rereeling machine. 5. Filature water A) The water pH near the isoelectric point of protein showed the best cohesion, but the farther water pH, the worser results were obtained. B) With the increasing of M-alkalinity in filature water, the results of cohesion were worse. Above all, we understood the tendency of the results of cohesion get worse when the M-alkalinity is increased above 200 ppm. C) By increasing the total hardness of the filature water, it improved the results of cohesion. Especially, when the total hardness was above 300ppm, the results were extremely high. 6. Effects combination of each results A) The result of effects combination in filature processes with the obtained best conditions was distinctively improved. But the results could not reach in mathematicaly double effect. When reelied under worse conditions, the results of cohesion test were too bad. There was "effect limit" for the promotion. B) Generally the results of cohesion were bad when the filature conditions(the temperature, pressure and the properties of water, etc) are processed as sericin loss to be high. On the other hand, the results were very good when lower sericin loss was controlled in filature conditions. C) When filature conditions such as reeling velocity and croissieur length provide pysical cohesion ability and when raw silk dry fast during reeling and re-reeling, we found the result of cohesion was better. 7. Correlation of silk testing items. A) A negative correlation exists between the results of cohesion test and cleanness defect. Another word, the result of cohesion test was found to be worse as cleanness defect increased. B) In cleanness, cohesion has negative correlation against the number of slugs, but we could not find any correlation against long loops, loose ends. C) Cohesion has negative correlation against average neatness and low neatness defect. The better the results of neatness respectively, the better the results of cohesion found. D) There is no correlation between tenacity and the results of cohesion test, but there was high positive correlation between the results of elongation and those of cohesion test. The more elongation, the better the results of cohesion was found.

  • PDF

A Model-Fitting Approach of External Force on Electric Pole Using Generalized Additive Model (일반화 가법 모형을 이용한 전주 외력 모델링)

  • Park, Chul Young;Shin, Chang Sun;Park, Myung Hye;Lee, Seung Bae;Park, Jang Woo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.11
    • /
    • pp.445-452
    • /
    • 2017
  • Electric pole is a supporting beam used for power transmission/distribution which accelerometer are used for measuring a external force. The meteorological condition has various effects on the external forces of electric pole. One of them is the elasticity change of the aerial wire. It is very important to perform modelling. The acceleration sensor is converted into a pitch and a roll angle. The meteorological condition has a high correlation between variables, and selecting significant explanatory variables for modeling may result in the problem of over-fitting. We constructed high deviance explained model considering multicollinearity using the Generalized Additive Model which is one of the machine learning methods. As a result of the Variation Inflation Factor Test, we selected and fitted the significant variable as temperature, precipitation, wind speed, wind direction, air pressure, dewpoint, hours of daylight and cloud cover. It was noted that the Hours of daylight, cloud cover and air pressure has high explained value in explonatory variable. The average coefficient of determination (R-Squared) of the Generalized Additive Model was 0.69. The constructed model can help to predict the influence on the external forces of electric pole, and contribute to the purpose of securing safety on utility pole.

The Effect of Additives in the Cardioplegic Solution on the Recovery of Myocardium, Compariosn Among Albumin, Mannitol, and Glucose (심마비용액의 삼투압을 유지하기위한 첨가 물질들의 차이가 심근보호에 미치는 영향)

  • Kim, Eun-Gi;Lee, Jong-Guk;Lee, Sang-Heon
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1058-1067
    • /
    • 1991
  • High potassium cardioplegia is a widely accepted procedure to enhance myocardial protection from ischemic injuries associated with open heart surgery. Maintaining optimum osmolarity of the cardioplegic solution is one of the required conditions for an ideal cardioplegic solution Albumin is an frequently added component for maintaining optimum osmolarity of clinically used cardioplegic solutions. But the source of albumin is human blood so that the supply is limited and the cost of manufacturing is relatively high. Recently there are moves to minimized the use of blood product for fear of blood-associated infections or immunological disorders. In this experiment, we substituted mannitol or glucose for albumin added to the cardioplegic solution which has been used at the Wonju Medical College, To determine whether addition of mannitol or glucose instead of albumin in the cardioplegic solution can produce satisfactory myocardial protection during ischemia, three different groups of isolated rat heart perfused by modified Langendorff technique were studied. Wonju Cardioplegic Solution was selected as a standard high potassium[18mEq/L of K+] cardioplegic solution. Three kinds of cardioplegic solution were made by modifying the composition maintaining the same osmolarity[339$\pm$1mOsm/Kg] Isolated rat heart were perfused initially with retrograde nonworking mode and then changed to working mode. After measuring the heart rate, systolic aortic pressure, aortic flow, coronary flow, ischemic arrest by aorta cross clamp and cardioplegia was made maintaining the temperature of water jacket at 10oC. The heart was rewarmed and reperfused after 60min of ischemic arrest with intermittent cardioplegia at the 30min interval. The time to return of heart beat and the time required to get. Regular heart beat were observed after reperfusion. The recovery rate of the functional variables-heart rate, systolic aortic pressure, aortic flow, coronary flow and cardiac output were calculated and compared among the three groups of different cardioplegia-albumin, mannitol, and glucose. The wet weight and dry weight was measured and the water content of the heart as figured out for comparison. The time to return of heart beat was fastest in the albumin group, The functional recovery rates were best in the albumin group also. In the above conditions, albumin was the best additive to the cardioplegic solution compared to the mannitol or glucose.

  • PDF

Influence of Electrode Position on Performance of Sparkjet Actuator Using Numerical Analysis (수치해석을 이용한 전극 위치에 따른 스파크제트 액츄에이터의 성능 연구)

  • Shin, Jin Young;Kim, Hyung-Jin;Kim, Kyu Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.753-760
    • /
    • 2019
  • Sparkjet actuator, also known as plasma synthetic jet actuator, which is a kind of active flow control actuator is considered as being high possibility for the supersonic flow control due to ejecting stronger jet compared to the other active flow control actuators. Sparkjet actuator generates high temperature and high pressure flow inside the cavity by using arc plasma and leads momentum by ejecting such flow through orifice or nozzle. In this research, numerical calculation of sparkjet actuator with respect to the location of electrodes which exists inside the cavity is conducted and the change of the performance of sparkjet actuator is suggested. As the location of electrodes goes closer to the bottom of the cavity, impulse is increased and the average pressure inside the cavity maintains higher. When the location of electrode is 25% and 75% of the entire cavity height, impulse is 2.515 μN·s and 2.057 μN·s, respectively. Each impulse is changed by about 9.92% and -10.09% compared to when the location of electrodes is 50% of the entire cavity height.