• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.035 seconds

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우
    • Journal of the Korea Safety Management & Science
    • /
    • v.1 no.1
    • /
    • pp.183-195
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30 ∼ 200 employees out of safety management agent ill the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

Pressure Loss and Forced Convective Heat Transfer in an Annulus Filled with Aluminum Foam (발포 알루미늄이 삽입된 환형관에서의 압력손실 및 강제대류 열전달)

  • Noh Joo-Suk;Lee Kye-Bock;Lee Chung-Gu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.855-862
    • /
    • 2005
  • An experimental investigation has been carried out for aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink for high performance forced water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kw/m^2$ and Reynolds number ranged from 120 to 2000. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while the significant augmentation in Nu is obtained. This technique can be used for the compactness of the heat exchanger.

A Study on Prediction Model of Heat Transfer Coefficient in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes (다관형 고밀도 순환유동층 열교환기의 열전달계수에 대한 예측모델 연구)

  • Park, Sang-Il
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.288-293
    • /
    • 2005
  • The pressure distribution and heat transfer coefficient were measured at room temperature in the high suspension density CFB heat exchanger with multiple vertical tubes and the effective density of CFB was determined. The theoretical model for predicting heat transfer coefficient was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement between them.

  • PDF

Thermal Structural Analysis of Steam Trap Bimetal Valve (스팀 트랩 바이메탈 밸브의 열 구조해석)

  • Kim, Dong Hwan;Kim, Dong Hyun;Ryu, Gyeong Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.799-805
    • /
    • 2012
  • In this study, structural thermal analyses for steam trap valve considering contact boundary condition have been conducted for high temperature and pressure conditions using nonlinear finite element method. Full steam trap model also including regulator and housing structures is considered in order to accurately simulate the complex valve mechanism and investigate thermal stress levels, and structural behaviors of core structural parts. It is typically shown that the present computational approach can give very useful results for design engineers so that the operating performance and structural safety of the steam trap valve can be verified in the design process.

Recycling of Poly(ethylene terephthalate) via Methanolysis without Catalyst (무촉매 메탄올 분해에 의한 Poly(ethylene terephthalate)의 재활용에 관한 연구)

  • Lee, Yoon-Bae;shin, Jae-Sick
    • Clean Technology
    • /
    • v.8 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • In order to recycle poly(ethylene terephthalate), methanolysis has been investigated at elevated temperature and under high pressure without catalyst to afford dimethyl terephthalate and ethylene glycol. The reaction was carried out under 62 atm, $310^{\circ}C$ for 50min to obtain 98% dimethyl terephthalate. The method has been suggested as a simple and economical one to recycle the poly(ethylene terephthalate).

  • PDF

Stroke Analysis of Large Bore Hydraulic Snubber Supporting Reactor Coolant System (원자로 냉각재 계통을 지지하는 대구경 유압식 스너버의 이동거리 해석)

  • 이상호;윤기석;전장환;박명규;엄세윤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.61-67
    • /
    • 1995
  • The steam generator, one of the major components in the reactor coolant system, plays an important role in transferring the thermal energy made in the reactor during normal operation to the secondary side and producing steam to drive turbine. A hydraulic snubber system is used in order to protect the steam generator under the dynamic loading condition and to absorb the thermal expansion transmitted by the reactor coolant piping due to high temperature and pressure during normal operation. In this study, the model for a geometrical linkage system is presented to analyze the snubber stroke of the steam generator and the parameters in the snubber stroke analysis are investigated. A method to analyze lever ratio of the linkage system which is required in the process of determining the snubber stiffness value is also presented. To discuss the validation of the suggested analysis, the analysis results are compared with the measured data during the hot functional test for the standardized 1000 Mwe pressurized water reactor plant under the construction.

  • PDF

Manufacturing Polymer/clay Nanocomposites Using a Supercritical Fluid Process

  • Jung, Hyun-Taek;Yoon, Ho-Gyu;Lim, Soon-Ho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.63-65
    • /
    • 2008
  • The increased interest in reducing the environmental effects caused by releasing organic compounds and aqueous waste has motivated the development of polymeric materials in supercritical fluids. Recently, supercritical fluids have been used in material synthesis and processing because of their special properties, such as high diffusivity, low viscosity, and low surface tension. Supercritical carbon dioxide is the most attractive because it is non-toxic, non-flammable, and has moderate critical temperature and critical pressure values. Supercritical carbon dioxide can also swell most polymers. In this study, we prepared polymer/clay nanocomposites using supercritical fluids. Cloisites 10A, 15A, 25A, and 30B used in this study are montmorillonites modified with a quaternary ammonium salt. The nanocomposites of polymer/clay were characterized by X-ray diffraction, thermogravimetric analysis, and differential scanning calorimetry.

A design of the annular induction electromagnetic pump by equivalent circuit modelling (등가회로 해석법에 의한 환단면형 유도전자펌프의 설계)

  • Kim, H.R.;Hong, S.H.;Hwang, J.S.;Min, B.T.;Nam, H.Y.;Cho, M.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

Synthesis and Characteristics of FePt Nanopowder by Chemical Vapor Condensation Process

  • Yu, Ji-Hun;Lee, Dong-Won;Kim, Byoung-Kee;Jang, Tae-Suk
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1196-1197
    • /
    • 2006
  • FePt binary-alloy nanopowder has been successfully synthesized by chemical vapor condensation process with two metal organic precursors, i.e., iron pentacarbonyl and platinum acetylacetonate. Average particle size of the powder was less than 50 nm with very narrow size distribution, revealing high dispersion capability. Characteristics of the powder could be controlled by changing process parameters such as reaction temperature, chamber pressure, as well as gas flow rate. Magnetic properties of the synthesized FePt nanopowder were investigated and analyzed in terms of the powder characteristics.

  • PDF

A Short Kinetic Mechanism for Premixed Flames of Aromatic Compound : Benzene (방향족 화합물 화염의 축소 반응 메카니즘 개발 : 벤젠)

  • Lee, Ki Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.20 no.4
    • /
    • pp.49-55
    • /
    • 2015
  • A short kinetic mechanism for premixed benzene/air flames was developed with a reduction method of Simulation Error Minimization Connectivity Method(SEM-CM). It consisted of 38 species and 336 elementary reactions. Flame speeds were calculated and compared with those from full mechanisms and experiments of other researchers. Flame temperature, the heat release rate, the concentration profiles of major species and radicals were also calculated with both mechanism. Those comparisons are in good agreement between the full mechanism and the short mechanism at high pressure condition. In numerical work the running time with the short mechanism was over 12 times faster than one with the full mechanism.