• Title/Summary/Keyword: high temperature high pressure

Search Result 4,161, Processing Time 0.033 seconds

A Study on the Viscosity Characteristics of Dewatered Sewage Sludge according to Thermal Hydrolysis Reaction (열가용화 반응에 의하여 탈수된 하수슬러지의 점도 특성에 관한 연구)

  • Song, Hyoung Woon;Han, Seong Kuk;Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.1
    • /
    • pp.27-34
    • /
    • 2014
  • demand for a low-cost treatment technology is high because the sewage sludge has an 80% or higher water content and a high energy consumption cost. This study apply the thermal hydrolysis reaction that consumes a small amount of energy for sludge treatment. The purpose of this study is to quantify the viscosity of sewage sludge according to reaction temperature. we measured continuously the torque of dewatered sludge by the reaction temperature. As the reaction temperature increased, the dewatered sludge is thermal hydrolysis under a high temperature and pressure. Therefore, the bond water in the sludge cells comes out as free water, which changes the dewatered sludge from a solid phase to slurry of a liquid phase. The results of the viscosity measurements according to the reaction temperature showed that the viscosity was very high at $270,180kg/m{\cdot}sec$ at a temperature of 293K, but rapidly decreased with increases in the reaction temperature to $12kg/m{\cdot}sec$ at a temperature of 400K and to $4kg/m{\cdot}sec$ at a temperature of 460K or higher, similar to the changes in the viscosity of water. And we was obtained the viscosity function of boundary condition for the optimal design of thermal hydrolysis reactor by numerical modeling based on the this results.

A Study on Film Boiling Heat Transfer in a Forced Convective Flow System (강제대류계(强制對流系)에 있어서 막비등열전달(膜沸騰熱傳達)에 관한 연구(硏究))

  • Kim, Y.T.;Kwon, S.S.;Jung, D.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.51-60
    • /
    • 1991
  • The aim of this study is to investigate the heat transfer characteristics in the transient cooling process of a high temperature wall. The slow transient cooling experiment was carried out with a copper block of high thermal capacity. The results of these experiments are as follows. 1. Temperature histories measured by the thermocouple, which is 0.99, 2.00, 2.99mm from the heat transfer surface showed monotonous during the cooling process. These variation are the curves of typical temperature histories in film-boiling, transition-boiling, and nucleate-boiling regions. 2. The temperature histories were measured by thermocouple installed in the copper block. The variations of the surface heat fluxes and surface temperature were computed from the numerical solution method TDMA from the measured temperature histories for radial position one dimensional heat transfer inverse problem. The boiling curves were found by the computed temperature histories. 3. The rewetting point which starts to change from film boiling to nucleate boiling is not connected with the mass velocity and it were found that the temperature of rewetting point indicated about $100^{\circ}C$. 4. The heat flux of rewetting point was about $10^5Kcal/m^2h$, at that time, the heat transfer coeficient indicated about $1000Kcal/m^2h^{\circ}C$ irrelevent to mass velocity. 5. The wall superheat decreases as the pressure increases. But I found that rewetting point appeared under higher condition in the wall temperature.

  • PDF

A study on the variation of skin temperature on the adult male at environment temperature (각 환경기온하에서의 성인남자 피부온에 관한 연구)

  • 심부자
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.71-88
    • /
    • 1996
  • For understanding skin temperature based on clothing design from a viewpoint of comfortable wearing, the skin temperature, physiological reactions(body temperature, blood pressure and pulse) and physilolgical response(thermal sensation, comfort sensation and perceptive sweaty sensation) were measured on condition tha t5 naked healthy male exposed to serveral environmental temperatures,( $20{\pm}1.0^{\circ}C$ ,$28{\pm}1.0^{\circ}C$ and $32{\pm}1.0^{\circ}C$). As the results of this testing, the regional skin temperature was varied for 90min just after expose to those the environment but was generally stabilized for the nest 90min. It was proved the difference of the regional skin temperature at low temperature environmental($20{\pm}1.0^{\circ}C$) was larger than at high temperature environmental($32{\pm}1.0^{\circ}C$) and inder serveral environmental temperature,the degree of the regional skin was not equal. Except in case of the thigh, the front of all regional skin temperature turned out higher than the back of them. According to change of environmental temperature, body temperature and pulse were altered. In the pshycological response, 'thermal sensation-comfort sensation' was felt to 'slightly warm - comfortable' at $28{\pm}1.0^{\circ}C$of the environmental temperature, and 'perceptive sweaty sensation', wneh it was said 'sweat' at only $32{\pm}1.0^{\circ}C$ of it.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM (SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구)

  • Eun, Sung-Sik;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

Interfacial Microstructure of Diffusion-Bonded W-25Re/Ti/Graphite Joint and Its High-Temperature Stability (확산 접합에 의해 제조된 텅스텐-레늄 합금/티타늄/그래파이트 접합체의 미세구조 및 고온 안정성)

  • Kim, Joo-Hyung;Baek, Chang Yeon;Kim, Dong Seok;Lim, Seong Taek;Kim, Do Kyung
    • Korean Journal of Materials Research
    • /
    • v.26 no.12
    • /
    • pp.751-756
    • /
    • 2016
  • Graphite was diffusion-bonded by hot-pressing to W-25Re alloy using a Ti interlayer. For the joining, a uniaxial pressure of 25 MPa was applied at $1600^{\circ}C$ for 2 hrs in an argon atmosphere with a heating rate of $10^{\circ}C\;min^{-1}$. The interfacial microstructure and elemental distribution of the W-25Re/Ti/Graphite joints were analyzed by scanning electron microscopy (SEM). Hot-pressed joints appeared to form a stable interlayer without any micro-cracking, pores, or defects. To investigate the high-temperature stability of the W-25Re/Ti/Graphite joint, an oxy-acetylene torch test was conducted for 30 seconds with oxygen and acetylene at a 1.3:1 ratio. Cross-sectional analysis of the joint was performed to compare the thickness of the oxide layer and its chemical composition. The thickness of W-25Re changed from 250 to $20{\mu}m$. In the elemental analysis, a high fraction of rhenium was detected at the surface oxidation layer of W-25Re, while the W-25Re matrix was found to maintain the initial weight ratio. Tungsten was first reacted with oxygen at a torch temperature over $2500^{\circ}C$ to form a tungsten oxide layer on the surface of W-25Re. Then, the remaining rhenium was subsequently reacted with oxygen to form rhenium oxide. The interfacial microstructure of the Ti-containing interlayer was stable after the torch test at a temperature over $2500^{\circ}C$.

A Study on Alternative Fan Selection and Verification in Military Electronic Equipment (방산용 전자장비의 팬 선정 및 검증에 관한 연구)

  • Jin, Sung Eun;Kim, Hwan Gu;Yoon, Eui Youl;Jeon, Hee Ho;Kim, Seung Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1091-1097
    • /
    • 2017
  • Sales of commercial-type cooling fans intended for application in military electronics are often discontinued during equipment production. This results in requirements for alternative fan selection as well as equipment performance and reliability tests, such as high-temperature operation testing. This study deals with alternative fan selection and verification methods that can be used during the production process. First, an alternative fan was selected by calculating the flow and pressure required to effectively cool the equipment, then the feasibility of the selected fan was verified using a reliable CFD heat dissipation analysis model. Following this, a high-temperature operation test was performed using the alternative fan in the equipment. Results demonstrated that the equipment satisfied its required function in a high-temperature environment, and the main parts as well as internal air temperature were found to be thermally stable.

Experimental Study on the Load Carrying Performance and Driving Torque of Gas Foil Thrust Bearings (가스 포일 스러스트 베어링의 하중지지 성능 및 구동 토크에 관한 실험적 연구)

  • Kim, Tae Ho;Lee, Tae Won;Park, Moon Sung;Park, Jungmin;Kim, Jinsung;Jeong, Jinhee
    • Tribology and Lubricants
    • /
    • v.31 no.4
    • /
    • pp.141-147
    • /
    • 2015
  • Gas foil thrust bearings (GFTBs) have attractive advantages over rolling element bearings and oil film thrust bearings, such as oil-free operation, high speed stability, and high-temperature operation. However, GFTBs have lower load carrying capacity than the other two types of bearings owing to the inherent low gas viscosity. The load carrying capacity of GFTBs depends mainly on the compliance of the foil structure and the formed hydrodynamic wedge, where the gas pressure field is generated between the top foil and the thrust runner. The load carrying capacity of the GFTBs is very important for the suitable design of oil-free turbomachinery with high performance. The aim of the present study is to identify the characteristics of the load carrying performance of GFTBs. A new test rig for the experimental measurements is designed to provide static loads up to 800 N using a pneumatic cylinder. The maximum operating speed of the driving motor is 30,000 rpm. A series of experimental tests—lift-off test, static load performance test, and maximum load capacity test—estimate the performance of a six-pad GFTB, in terms of the static load, driving torque, and temperature. The maximum load capacity is determined by increasing the static load until the driving torque rises suddenly with a sharp peak. The test results show that the torque and temperature increase linearly with the static load. The estimated maximum load capacity per unit area is approximately 80.5 kPa at a rotor speed of 25,000 rpm. The test results can be used as a design guideline for GFTBs for realizing oil-free turbomachinery.

A Study on High-Temperature Fuel Injection Characteristics through Swirl Injectors (스월 인젝터를 통한 고온 연료의 분사특성 연구)

  • Lee, Hyung Ju;Choi, Hojin;Kim, Ildoo;Hwang, Ki-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.11-19
    • /
    • 2013
  • An experimental study was conducted to investigate fuel injection characteristics through swirl injectors when the fuel was heated to very high temperature conditions. Three swirl injectors with different orifice diameters and swirler geometries were used to measure the flow coefficient (${\alpha}$) for the injection pressure ranges between 3 and 10 bar and the fuel temperature from 50 to $270^{\circ}C$. The results showed that the variation characteristics of ${\alpha}$ with respect to cavitation number ($K_c$) were highly dependent on both the orifice diameter and the swirler geometry. In addition, the characteristics of ${\alpha}$ variation with respect to AR, the area ratio of the flow through the swirler and the orifice, has revealed that the effect of boiling is retarded but the slope of decreasing ${\alpha}$ after the boiling effect is present tumbles as AR increases.

A Study on the Leakage Evaluation for Power Plant Valve Using Infrared Thermography Method (적외선열화상에 의한 발전용 밸브 누설명가 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.110-115
    • /
    • 2010
  • This study was conducted to estimate the feasibility using thermal image measurement that is applicable to internal leak diagnosis for the power plant valve. Abnormal heating of valve surface associated with high temperature steam f10w toward valve outlet side in the condition of low temperature is a primary indicator of leakage problems in high temperature and pressure valves. Thermal imaging enables to see the invisible thermal radiation that may portend impending damage before their condition becomes critical. When steam flow in valve outlet side in the condition of low temperature is converted into heat transmitted through the valve body due to the internal leakage in valve. The existence of abnormally increasable leakage rate in the valve will result in abnormally high levels of heat to be generated that can be quickly identified with a thermal image avoiding energy loss or damage of valve component. From the experimental results, it was suggested that the thermal image measurement could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

Preparation of Large Area $TiO_2$ Thin Films by Low Pressure Chemical Vapor Deposition

  • Jeon, Byeong-Su;Lee, Jung-Gi;Park, Dal-Geun;Sin, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.4 no.8
    • /
    • pp.861-869
    • /
    • 1994
  • Chemical vapor deposition using titanium tetra isopropoxide(TTIP) was employed to investigate effects of process parameters on the uniformity of $TiO_{2}$this films deposited on Indium Tin Oxide (ITO)coated glass. Deposition experiments were carried out at temperatures ranging from $300^{\circ}C$ to $400^{\circ}C$ under the pressure of 0.5~2 torrin a cold wall reactor which can handle 200mm substrate. It was found that the growth rate of $TiO_{2}$was closely related to the reaction temperature and the ractant gas compositions. Apparent activation energy for the deposition rate was 62.7lkJ/mol in the absence of $O_{2}$ and 100.4kj/mol in the presence of $O_{2}$, respectively. Homogeneous reactions in the gas phase were promoted when the total pressure of the reactor was increased. Variance in the film thickness was less than a few percent, but at high deposition rates film thickness was less uniform. Effects of reaction temperature on $TiO_{2}$ thin film characteristic was investigated with SEM, XRD and AES.

  • PDF