• Title/Summary/Keyword: high step-up

검색결과 699건 처리시간 0.03초

제어구간에 의한 스케듈링 기법 (Scheduling Technique for Control Step)

  • 송정영;백남우
    • 공학논문집
    • /
    • 제4권1호
    • /
    • pp.35-45
    • /
    • 2002
  • This paper deals with the scheduling problems which are the most important subtask in High-Level Synthesis. Especially, we have concentrated our attentions on the data-path scheduling which can get the structural informations from the behavioral algorithm as a first step in synthesis procedure. Suggest Forward scheduling methode is executed the ASAP and ALAP scheduling to use the fifth – order elliptic wave filter of a standard benchmark model, and then it is drawing up T.N matrix table by the number of resource and control-step, using the table extract of the simple than down-limit value of the control-step for the number of given resource to use this table. All of existing list scheduling techniques determine the priority functions first, and then do the operation scheduling, But, the suggested forward scheduling technique does the schedule first, and determines the priority functions if needed in scheduling process.

  • PDF

지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향 (EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES)

  • 황성연;이경하;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.378-384
    • /
    • 2003
  • This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.

전류불연속 제어에 의한 새로운 PFC 승압형 AC-DC 컨버터 (A Novel Step-up AC-DC Converter with PFC by Discontinuous Current Control)

  • 김춘삼;심재선;김천식;이현우;곽동걸
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.142-148
    • /
    • 2006
  • 본 논문에서는 역률개선과 고효율로 동작되는 새로운 승압형 AC-DC 컨버터를 제안한다. 제안된 컨버터는 입력전류 불연속제어로 구동되고, 스위치의 시비율 일정제어에 의해 입력전류는 교류 입력전압의 크기에 비례된 불연속적인 정현파 형태로 주어진다. 그 결과 입력역률은 거의 단위역률로 주어지고, 시비율 일정제어에 의해 제안된 컨버터는 제어기법이 간단하게 된다. 일반적으로 전류불연속 제어에 의한 컨버터의 경우, 사용된 스위치의 턴-온 동작은 영전류 스위칭으로 되는 장점이 있지만, 스위치의 턴-오프 동작은 최대 전류에서 스위칭되어 스위칭 손실을 증대시키고 스위치의 과중한 스트레스를 가져오게 된다. 이것은 컨버터의 효율을 저하시키는 요인이다. 본 논문에서는 부분적인 공진회로 동작에 의한 새로운 소프트 스위칭 회로가 설계되어 사용된 제어스위치들의 턴-온, 턴-오프 동작을 소프트 스위칭으로 만들어 컨버터의 효율을 증대시킨다.

A New Complex Minimally Invasive Thread Lift Method for One-Time Three-Step Fixation of the Face and Neck Soft Tissues

  • Zhukova, Olga;Dydykin, Sergey;Kubikova, Eliska;Markova, Natalia;Vasil'ev, Yuriy;Kapitonova, Marina
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.296-303
    • /
    • 2022
  • Background In recent years thread lift has become widespread; however, existing methods need to improve their long-term outcome, which requires considering topographic anatomy of face and neck, especially the ligamentous apparatus. This study aims to assess the effectiveness and safety of an innovative method of one-time three-step thread facelift, which provides an additional support to the ligamentous structures of the upper, middle, and lower thirds of the face and neck. Methods The study included 357 patients aged 32 to 67 years with various morphotypes of aging. The original method of thread lift was applied, and its effectiveness was followed up for to 2 years. The Wrinkle Severity Rating Score (WSRS) and Global Aesthetic Improvement Scale (GAIS) scores were used for assessment by investigators, independent observers, and patients. Statistical significance was determined using paired t-test and chi-square test. Results The mean WSRS score was 3.88 ± 0.88 before the thread lift, 1.93 ± 0.81 one month after the procedure, and 2.36 ± 0.85 after 2 years of follow-up. The mean GAIS was 4.80 ± 0.04 one month after thread lift, and 4.01 ± 0.04 after 2 years, while in the patients' assessment Global Satisfaction Scale was 4.86 ± 0.02 and 4.10 ± 0.02, respectively. There were no clinically significant complications throughout the observation period. Conclusion The new method of one-time three-step thread fixation of the soft tissues of the face and neck demonstrated a high degree of satisfaction by both experts and patients after 2 years of follow-up. It showed high efficacy and safety, including in the group of patients with pronounced age-related changes of the skin of face and neck.

평균 영상 추정을 이용한 고속 플랙탈 영상 복원 알고리즘 (A fast fractal decoding algorithm using averaged-image estimation)

  • 문용호;박태희;김재호
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2355-2364
    • /
    • 1998
  • In conventional fractal decoding procedure, the reconstructed image is obtained by a rpredefined number of iterations starting with an arbitrary initial image. Its convergence speed depends on the selection of the initial image. It should be solved to get high speed convergence. In this paper, we theoretically reveal that conventional method is approximately decomposed into the decoding of the DC and AC components. Based on this fact, we proposed a novel fast fractal decoding algorithm made up of two steps. The averaged-image considered as an optimal initial image is estimated in the first step. In the second step, the reconstructe dimag eis genrated from the output image obtained in the first step. From the simulations, it is shown that the output image of the first step approximately converges to the averaged-image with only 15% calculations for one iteration of conventional method. And the proposed method is faster than various decoding mehtods and evenly equal to conventioanl decoding with the averaged-image. In addition, the proposed method can be applied to the compressed data resulted from the various encoding methods because it does not impose any constraints in the encoding procedure to get high decoding speed.

  • PDF

A New High Efficient Bi-directional DC/DC Converter in the Dual Voltage System

  • Lee Su-Won;Lee Seong-Ryong;Jeon Chil-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.343-350
    • /
    • 2006
  • This paper introduces a new high efficient bi-directional, non-isolated DC/DC converter. Through variations of the topology of the conventional Cuk converter, an optimum bi-directional DC/DC converter is proposed. Voltage and current in the proposed DC/DC converter are continuous. Furthermore, the efficiency in both step-up and step-down mode is improved over that of the conventional bi-directional converter. To prove the validation for the proposed converter, simulations and experiments are executed with a 300W bi-directional converter.

Terfenol-D 작동기를 이용한 초정밀 스텝모터의 성능평가 (High Precision Stepping Motor Using Terfenol-D Actuators: Its Performance Test)

  • 김재환;이현일
    • 한국정밀공학회지
    • /
    • 제17권2호
    • /
    • pp.220-226
    • /
    • 2000
  • High precision step motor using Terfenol-D linear actuators is proposed and its performance is tested. Four Terfenol-D linear actuators are set up perpendicular to the rotor and saw-tooth current signals are applied on the actuators. It was found that the rotation angle is increased as the excitation current, the inertia of the rotor, and the contact force between the rotor and the push device are increased. The rotation angle per step of $0.001^{\circ}$ and blocking torque of 0.2Nm are achieved. The effect of the time delay between the excitation signals is also investigated.

  • PDF

A 3 kW Bidirectional DC-DC Converter for Electric Vehicles

  • Ansari, Arsalan;Cheng, Puyang;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.860-868
    • /
    • 2016
  • A bidirectional DC-DC converter (BDC) is an indispensable electrical unit for the electric vehicles (EVs). High efficiency, high power density, isolation, light weight and reliability are all essential requirements for BDC. In this paper, a 3 kW BDC for the battery charger of EVs is proposed. The proposed converter consists of a half-bridge structure on the primary side and an isolation transformer and a synchronous rectifier structure on the secondary side. With this topology, minimum number of switching devices are required for bidirectional power flow between the two dc buses of EVs. The easy implementation of the synchronous rectification gives advantages in terms of efficiency, cost and flexibility. The proposed BDC achieves high efficiency when operating in both modes (step-up and step-down). A 3 kW prototype is implemented to verify theoretical analysis and the performance of the proposed converter.

Performance Improvement of Power Control System for Driving MGT

  • Lee Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권7호
    • /
    • pp.744-749
    • /
    • 2005
  • This paper describes the performance improvement of power control system of magnetron (MGT) for microwave oven. The MGT is used extensively in household microwave oven and industrial microwave heating devices, and is operated by 3.0[kV] $\∼$5.0[kV] dc high voltage. The proposed power supply is consisted of a bridge rectifier, step-up converter(SUC) and its controller, half bridge inverter(HBI) and its controller, and full wave double voltage rectifier(DVR). In the proposed system, a good power factor can be obtained by the SUC' switching method that the inductor current waveforms follows that of the rectified voltage, and a line input power can be controlled to a range of 17.5[$\%$] by duty ratio (DR) adjustment of the HBI.

절연된 부스트 변환기의 해석 (Analysis of Isolated Boost Converter)

  • 김희선;정대택;원화영;이형주;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.84-86
    • /
    • 2009
  • Isolated boost converter is desirable in the dc/dc converter applications where isolation is required and a large step up is needed. In this paper, it is proposed and analyzed the isolated boost converter which can step up low input voltage to high output voltage using transformer. Instead of using a conventional scheme, the proposed converter has the reset winding for volt-sec balance of transformer. Finally, the validity of the proposed isolated boost converter is verified by simulation.

  • PDF