DOI QR코드

DOI QR Code

EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES

지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향

  • Hwang, Sung-Yeon (Department of Conservative Dentistry & Institute for Oral Bioscience College of Dentistry, Chonbuk National University) ;
  • Lee, Kyung-Ha (Department of Conservative Dentistry & Institute for Oral Bioscience College of Dentistry, Chonbuk National University) ;
  • Yu, Mi-Kyung (Department of Conservative Dentistry & Institute for Oral Bioscience College of Dentistry, Chonbuk National University) ;
  • Lee, Kwang-Won (Department of Conservative Dentistry & Institute for Oral Bioscience College of Dentistry, Chonbuk National University)
  • 황성연 (전북대학교 치과대학 치과보존학 교실 및 구강생체과학연구소) ;
  • 이경하 (전북대학교 치과대학 치과보존학 교실 및 구강생체과학연구소) ;
  • 유미경 (전북대학교 치과대학 치과보존학 교실 및 구강생체과학연구소) ;
  • 이광원 (전북대학교 치과대학 치과보존학 교실 및 구강생체과학연구소)
  • Published : 2003.09.01

Abstract

This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.

Keywords

References

  1. Braem M, Lambrecchts P and Vanherle G. : Stress induced cervical lesion. J Prosthet Dent 67:718-722, 1992 https://doi.org/10.1016/0022-3913(92)90178-D
  2. Levitch LC, Barder JD, Shugars DA and Heymann HO : Non carious cervical lesionl(review). J Dent 22:195-207, 1994 https://doi.org/10.1016/0300-5712(94)90107-4
  3. Yoshiyama M, Noire Y, Azoic K et al : Transmission electron microscopic characterization of hypersensitive hyman radicular dentin J Dent Res. 69:1293-1297, 1990 https://doi.org/10.1177/00220345900690061401
  4. Pashley DH : Dentin permeability. dentin sensitivity, and treatment through tubule occlusion. J Endodont 12:465-474, 1986 https://doi.org/10.1016/S0099-2399(86)80201-1
  5. Kern DG, Scheidt and Pashley DH : Dentinal tubule occlusion and root hypersensitivity. J. Periodont. 62(7):421-428, 1991
  6. Jean Camps, Stephana Piazant. Jacoues Dejou. and Jean Claude Franquin : Effect of desensitizing agents on human dentin permeability. Am J Dent. 11(6):286-290, 1998
  7. Jain P, Vargas MA, Denehv GE and BoyerDB : Dentin desensitizing agents: SEM and X ray microanalysis assessment. Am J Dent 10(1):21-26, 1997
  8. Mausner IK, Goldstein GR and Georgescu M : Effect of two dentinal desensitizing agents on retention of complete cast coping using four cements. J Prosthetic Dent 75(2):129-134, 1996 https://doi.org/10.1016/S0022-3913(96)90088-8
  9. Zhang Y, Agee K, Pashley DH and Pashley EL : The effects of pain free desensitizer on dentine permeability and tobule occlusion over time, in vitro. J Clin Perlodontol 25:884-891, 1998 https://doi.org/10.1111/j.1600-051X.1998.tb02386.x
  10. Gillam DG, Mordan NJ, Sinodiou AD, Tang JY, Knowles JC and Otbsson R : the effect of oxalate containing products on the exposed dentine surface: an SEM investigation. J Oral Rehabilitation 28:1037-1044, 2001 https://doi.org/10.1046/j.1365-2842.2001.00775.x
  11. Snuggs AK Cox LK et al : colloidal MSE for differential diagnosis and treatment of dentin permeability. In: Shimona M, Maeda T, Suda H, etal. dentin/pulp complex Quintessence 245-247, 1996
  12. Seam SF, Erthral BS, Ribeiro M, Kroll L and Pereira GDS : The influence of a dentin desensitizer on the microtensile bond strength of two bonding systems. Operative Dentistry 27: 154-160, 2002
  13. Pashley EL, Tao Land Pashely D : Effest of oxalate on dentin bonding. Am J Dent 6(2) :61-64, 1993
  14. Edward J Swift JR, Ashley H. Lloyd and David A Felton : The effect of resin desensitizing agents on crown retention. JADA 128:195-200, 1997 https://doi.org/10.14219/jada.archive.1997.0164
  15. Nantiya H Yim, Frederick A, Rueggeberg W, Frank Caughman, Michael Oeroer F and David H Pashley : Effect of dentin desensitizers and cementing agents on etention of fuul crowns using standardized crown preparations. J Prosthet Dent 83:459-465, 2000 https://doi.org/10.1016/S0022-3913(00)70042-4
  16. Scene K, Taira Y, Matsumura H and Atsura : Effect of desensitizers on bond strength of 접착제 luting agents to dentin. J Oral Rehabilitation 28: 1122-1128, 2001 https://doi.org/10.1046/j.1365-2842.2001.00756.x
  17. Tagami J, Tao L and Pashley DH : Correlation among dentin depth, permeability and bond strength of adhesive resins. Dental Material 6(1):45-60, 1990 https://doi.org/10.1016/0109-5641(90)90044-F
  18. David H Pashley, Ricardo M Carvalho, Hideheko Sane and Masatoshi Nakajima : The microtensile bond test : a review. J adhesive Dent 1:299-309, 1999
  19. Steven R Armstrong and Daniel B Boyer : Microtensile bond strength testing and failure analysis of two dentin adhesives. Dent Mater 14:44-50, 1998 https://doi.org/10.1016/S0109-5641(98)00009-8
  20. Henry O Trowbridge and David R, Silver : A review of current approaches to in office management of tooth hypersensitivity a Review Dental Clinics of North America 34(3):561-578, 1990
  21. Lucinda C Hogan and Michael F Burrow : The microtensile strength of bonding resins. Austrian Dental J 46(3):194-197, 2001 https://doi.org/10.1111/j.1834-7819.2001.tb00281.x