• 제목/요약/키워드: high speed motion camera

검색결과 112건 처리시간 0.026초

카메라를 이용한 구조물의 동특성 추출 (Modal Parameter Extraction Using a Digital Camera)

  • 김병화
    • 한국소음진동공학회논문집
    • /
    • 제18권12호
    • /
    • pp.1229-1236
    • /
    • 2008
  • A set of modal parameters of a stay-cable have been extracted fi:on a moving picture captured by a digital camera supported by shaking hands. It is hard to identify the center of targets attached on the cable surface from the blurred cable motion image, because of the high speed motion of cable, low sampling frequency of camera, and the shaking effect of camera. This study proposes a multi-template matching algorithm to resolve such difficulties. In addition, a sensitivity-based system identification algorithm is introduced to extract the natural frequencies and damping ratios from the ambient cable vibration data. Three sets of vibration tests are conducted to examine the validity of the proposed algorithms. The results show that the proposed technique is pretty feasible for extracting modal parameters from the severely shaking motion pictures.

Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera

  • Ozyurek, Taha;Keskin, Neslihan Busra;Furuncuoglu, Fatma;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.224-231
    • /
    • 2017
  • Objectives: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. Materials and Methods: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). Results: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC ($3,464.45{\pm}487.58$) and WO ($3,257.63{\pm}556.39$) groups had significantly longer cyclic fatigue life compared with TFA ($1,634.46{\pm}300.03$) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. Conclusions: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

스프링구동 링크를 가진 기중 회로차단기의 동적 분석 (Dynamic Analysis of Air Circuit Breaker with Spring-Actuated Linkage)

  • 안길영;권병희;오일성;윤영관;최종웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.812-815
    • /
    • 1997
  • A dynamic model of air circuit breaker with a spring-actuated linkage is derived, and its validation for analysis and design, particularly appropriateness for an analysis of high-speed motion behavior are checked through experiments. The dynamic model is developed through the modeling process based on ADAMS and Pro/Engineer. The simulation results of derived dynamic models for the rapid closing and opening operations are compared with actual responses using a high-speed camera and investigated to validate their usefulness.

  • PDF

Visual Precise Measurement of Pile Rebound and Penetration Movement Using a High-Speed Line-Scan Camera

  • Lim, Mee-Seub;You, Bum-Jae;Oh, Sang-Rok;Han, Song-Soo;Lee, Sang-Hun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.341-346
    • /
    • 2002
  • When a construction company builds a high structure. many piles should be driven into the ground by a hammer whose weight is 7,000 kg in order to make the ground under the structure safe and strong. So. it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously. Especially- by adopting a line-scan CCD camera whose line rate is 20 ㎑. the measurement performance of dynamic characteristics of the pile at impact instant is improved dramatically.

키위나무의 바람에 대한 특성연구 (Basic characteristics of wind-blown kiwifruit vines)

  • 강종훈;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.101-104
    • /
    • 2007
  • Kiwifruit vines with broad leaves are easily torn or shed by high-speed wind. In this study, the threshold wind speed at which a cane is broken was investigated experimentally with varying physical parameters of a kiwifruit vine under two different ABL (atmospheric boundary layer) conditions. In addition, the temporal variation of wind-blown young canes was visualized using a high-speed camera. The average threshold wind speeds for ABL types A and B are about 20.5 m/s and 18.9 m/s, respectively. A wind-blown young cane takes periodic up-and-down motion when it is broken off. The mean motion frequency of young canes of the kiwifruit vines was found to be about 4.5Hz.

  • PDF

Observation of bubble dynamics under water in high-magnetic fields using a high-speed video camera

  • Lee, Seung-Hwan;Minoru Takeda
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.291-298
    • /
    • 2004
  • The observations of rapid motion of bubbles under water for approximately 50 ms or less in high-magnetic fields of 10 T have been carried out successfully for the first time. The observation system constructed is composed of a high-speed video camera, a telescope, a cryostat with a split-type superconducting magnet, a light source, a mirror and a transparent sample cell. Using this system, the influence of magnetic field on the path and shape of single bubbles of O$_2$ (paramagnetism) and N$_2$ (diamagnetism) has been examined carefully. Experimental values describing the path are in good agreement with theoretical values calculated on the basis of the magneto-Archimedes effect, despite the effect of magnetism on the bubble. However, no effect of magnetism on the shape of the bubble is observed. In addition, the influence of magnetic field on drag coefficient of the bubble is discussed.

  • PDF

Observation of bubble dynamics under water in high-magnetic fields using a high-speed video camera

  • Lee, Seung-Hwan;Takeda, Minoru
    • 한국항해항만학회지
    • /
    • 제28권2호
    • /
    • pp.141-148
    • /
    • 2004
  • The observations of rapid motion of bubbles under water for approximately 50ms or less in high . magnetic fields of 10 T have been carried out successfully for the first time. The observation system constructed is composed of a high-speed video camera, a telescope, a cryostat with a split-type superconducting magnet, a light source, a mirror and a transparent sample cell. Using this system, the influence of magnetic field on the path and shape of single bubbles of $O_2$(paramagnetism) and $N_2$ (diamagnetism) has been examined carefully. Experimental values describing the path are in good agreement with theoretical values calculated on the basis of the magneto-Archimedes effect, despite the effect of magnetism on the bubble. However, no effect of magnetism on the shape of the bubble is observed In addition, the influence of magnetic field on drag coefficient of the bubble is discussed.

평등전계에서 도전성 구형 입자의 운동 (Motion of Conductive Spherical Particle under Uniform Electric Field)

  • 임헌찬
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

Visual Measurement of Pile Movement for the Foundation Work using a High-Speed Line-Scan

  • Lim, Mee-Seub;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1802-1807
    • /
    • 2004
  • When a construction company builds a high structure, many piles should be driven into the ground by a hammer whose weight is 7,000 Kg in order to make the ground under the structure safe and strong. So, it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously

  • PDF

상용화 된 고속카메라와 후두내시경을 이용한 성대촬영 방법의 소개 (Commercially Available High-Speed Cameras Connected with a Laryngoscope for Capturing the Laryngeal Images)

  • 남도현;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.133-138
    • /
    • 2010
  • Background and Objectives : High-speed imaging can be useful in studies of linguistic and artistic singing styles, and laryngeal examination of patients with voice disorders, particularly in irregular vocal fold vibrations. In this study, we introduce new laryngeal imaging systems which are commercially available high speed cameras connected with a laryngoscope. Materials and Method : The laryngeal images were captured from three different types of cameras. First, the adapter was made to connect with laryngoscope and Casio EX-F1 to capture the images using $2{\times}150$ Watt Halogen light source (EndoSTROB) at speeds of 1,200 tps (frame per second)($336{\times}96$). Second, Phantom Miro ex4 was used to capture the digital laryngeal images using Xenon Nova light source 175 Watt (STORZ) at speeds of 1,920 fps ($512{\times}384$). Finally, laryngeal images were captured using MotionXtra N-4 with 250 Watt halogen lamp (Olympus CLH-250) light source at speeds of 2,000tps ($384{\times}400$) by connecting with laryngoscope. All images were transformed into the Kymograph using KIPS (Kay's image processing Software) of Kay Pentex Inc. Results: Casio EX-F1 was too small to adjust the focus and screen size was diminished once the images were captured despite of high resolution images. High quality of color images could be obtained with Phantom Miro ex4 whereas good black and white images from Motion Xtra N-4 Despite of some limitations of illumination problems, limited recording time capacity, and time consuming procedures in Phantom Miro ex4 and Motion Xtra N-4, those portable devices provided high resolution images. Conclusion : All those high speed cameras could capture the laryngeal images by connecting with laryngoscope. High resolution images were able to be captured at the fixed position under the good lightness. Accordingly, these techniques could be applicable to observe the vocal fold vibration properties in the clinical practice.

  • PDF