• Title/Summary/Keyword: high safety

Search Result 10,547, Processing Time 0.046 seconds

A Study of Potential Buyers' Consciousness of Single-Family Housing in Ulsan (단독주택에 대한 울산시 거주자의 주의식 연구)

  • Kim, Ji-Suk;Yang, Se-Hwa
    • Journal of Families and Better Life
    • /
    • v.28 no.6
    • /
    • pp.35-46
    • /
    • 2010
  • The purpose of the study was to identify the potential buyers' consciousness of single-family housing to provide useful data to help future single-family housing supplies in Ulsan. The study selected residents in Ulsan, who were over twenty and had an interest in living in a single-family housing. A survey was conducted from September 11, 2008 to September 25, 2008. The sample consisted of 364 persons who are currently live in Ulsan metropolitan area. The results are as following. About two thirds of the sample had the desire to live in a single-family housing. Moving into a single-family housing had financial preparation as the greatest issue. When moving into a single-family housing, the convenience of the residential district was the greatest consideration, whether or not it is a green environment, pollution level, etc. The potential buyers valued environment-friendly features and also had a very strong desire to own their own house. Many of them wanted to design and build their own single-family housing within a budget of 100-200 million KRW. In terms of the location, there was a higher preference for the riverside or lakeside rural areas outside the city. In terms of size, the preference was less than $330m^2$, which includes $99-132m^2$ for residential. When considering a single-family housing the direction was the most important feature, along with eco-friendly and safer materials and equipments. When building the single-family housing the potential buyers considered the community spaces first with a preference for having three bedrooms and two bathrooms. For the exterior, they wanted a unique shape of roof and there were high preferences for brown and beige colors. In terms of housing complexes, the potential buyers preferred individual unit types over complexes. If they preferred housing complexes, they wanted the cluster form complex with about 10-30 units. The complex also required a park-like setting with a guard system, which shows that convenience and safety were the most important features. In terms of complex management, they considered environmental management as the most important feature. The potential buyers were willing to pay belw 200,000 KRW, which showed their desire to minimize financial burdens.

Deduction of affecting factors for selecting the way of going into the main building of an apartment complex when constructing an underground parking lot. (지하주차장 공사시 주동진입방법 선정 영향요인 도출)

  • Song, Nak-Hyun;Whang, Kyoung-Jin;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.995-998
    • /
    • 2007
  • The number of households old over as much as 20 years is expected to get increased rapidly more than 1,000,000(1 million). As a measure to this fact remodeling is being revitalized over the country. parking lots expansion actually takes up a great deal of weight among the requirement for remodeling. When constructing a parking lot for enlargement, the way of going into the main building determines such construction features as selection of Retaining Wall Method, installation of an elevator, parking measure of capacity, etc. This study derived the affecting factors for selecting the way of going into the main building when constructing an underground parking lot. In a research way, we examined the features on each method of going into the main building in an apartment complex through an in-depth interview with some experts after investigating the method of enlarging an underground parking lot and going into the main building. After that, we derived the affecting factors for selecting the way of going into the main building. The affecting factors include constructability, convenience, economic efficiency as a high level as well as existence and nonexistence of basement and removal, safety of current building, parking measure of capacity, amenity, inhabitant traffic line, construction expenses and construction duration as a low one. This study will be applied as a reference for selecting the way of going into the main building when constructing an underground parking lot especially targetted on an old apartment house.

  • PDF

A Study of Working Environment for Automotive Painting in Auto Repair Shops and Workers' Exposure to Hazardous Chemicals (자동차 정비업체 도장공정의 작업환경 및 근로자 노출 실태에 관한 연구)

  • Sim, Sang-Hyo;Jeoung, Chun-Hwa;Lim, Jin-Suk;Lee, Hyung-Gu;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.153-161
    • /
    • 2009
  • The purpose of this paper is to evaluate 1) blood lead levels of workers at auto repair shops as Biological Exposure Indices (BEI) of toxic substances such as lead and toluene that are produced during automotive painting process, 2) the differences depending on personal characteristics of workers who have been exposed to toluene by using urine hippuric acid concentration as a marker and 3) the correlation between the concentration of hazardous chemicals in each workplace and the BEL. All subjects were male with a mean age of 36.2 years. In terms of age, most were in the 30 to 40 age group (13 persons, 48.1%). In relation to the length of work experience, the highest proportion had experience of 10 years of less (18 persons, 66.7%). Twenty three workers were cigarette smokers (85.2%) while 4 (14.8%) were non-smokers. In addition, more than 80% of the workers drank alcohol. Dust concentration and toluene exposure during automotive painting showed no significant difference with age, length of work experience, smoking and drinking while a significant difference (p<0.05) has been detected between lead concentration and smoking. The geometric mean of dust concentration, lead concentration and toluene concentration were $0.38mg/m^3,\;0.0021mg/m^3$ and 1.08ppm respectively. In addition, the geometric mean of blood lead levels and urine hippuric acid concentration were $1.70{\mu}g/dl$ and 0.25g/g respectively, which were lower than the standard levels suggested by the Ministry of Labor. To determine the influential factors on blood lead and urine hippuric acid concentrations, a correlation analysis has been conducted with variables of air, lead and toluene concentrations, age, length of work experience and amount of cigarette smoking. According to the analysis, a relatively high correlation (p<0.01) has been observed between air lead concentration and biological sample concentration.

Development of Multi-span Plastic Greenhouse for Tomato Cultivation (토마토 재배용 연동 플라스틱 온실 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.428-436
    • /
    • 2012
  • This study aimed to develop the multi-span plastic greenhouse which is suitable for tomato cultivation and is safe against climatic disasters such as typhoon or heavy snow. The width and heights of eaves and ridge of newly developed tomato greenhouse are 7, 4.5 and 6.5 m, respectively. The width is the same but the eaves and ridge heights are 1.8 and 2 m higher than conventional 1-2 W greenhouses, respectively. Cross beam has been designed as a truss structure so it can sustain loads of tomato and equipment. Tomato greenhouse has been designed according to climatic disaster preventing design standard maintaining the high height. In other words, the material dimensions and interval of materials including column and rafter have been set to stand against $40m{\cdot}s^{-1}$ of wind and 40 cm of snow. Tomato greenhouse has been equipped with rack-pinion type roof vents which have been used in glass greenhouse in order to prevent excessive rise in air temperature. This vent type is different from that of 1-2 W type greenhouse which is made by rolling up and down the vinyl at upper part of column. Roof vents are installed at ridge, and thus external air inflow and natural ventilation are maximized. As the height increases, heating cost increase as well and, therefore, tomato greenhouse has been equipped with multi-layered thermal curtain, of which thermo-keeping is excellent, to prevent heat from escaping.

Screening of Ochratoxin A Producing Fungi from Greenhouse Horticulture (시설원예산물로부터 Ochratoxin A 생성 곰팡이의 검색)

  • Kang, Sung-Jo;Park, Bong-Jung;Lee, Jong-Ok;Kang, Jin-Soon;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1415-1419
    • /
    • 1998
  • In order to evaluate the safety of greenhouse horticultures, a large number sample sources were collected, and the fungi of Aspergillus sp. and Penicillium sp. were isolated from them. Indirect competitive ELISA method and high performance liquid chromatography (HPLC) were applied to confirm the ochratoxin A producing abilities of isolated strains. One hundred ninety two sample sources including soil, pepper, strawberry and water mellon were collected for fungi isolation from western Gyeongnam, Andong and Gyeongbok. One hundred forty two strains of Aspergillus sp. and one hundred fifty three strains of Penicillium sp. were isolated respectively from them. The isolated fungi were tested for the production of ochratoxin A by ELISA. After culture of them on the modified sucrose low salt medium at $28^{\circ}C$ for 15 days, we found that five strains of Penicillium sp. produced ochratoxin A at the levels of $0.084{\sim}2.128\;{\mu}g/mL$. Among them, #129-2 strain isolated from water melon, showed the highest level of ochratoxin A as $2.128\;{\mu}g/mL$ broth. However, all of isolated Aspergillus sp. didn't produce ochratoxin A. When we compared the results of ELISA method with HPLC method, ochratoxin A production of each isolated strains showed very similar levels.

  • PDF

Dental Treatment of a Patient with Cerebral Palsy under General Anesthesia (뇌성마비 환자의 전신마취 하 치과치료)

  • Chung, Jun-Min;Seo, Kwang-Suk;Yi, Young-Eun;Han, Hee-Jung;Han, Jin-Hee;Kim, Hye-Jung;Shin, Teo-Jeon;Kim, Hyun-Jeong;Yum, Kwang-Won;Chang, Ju-He
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.8 no.1
    • /
    • pp.22-28
    • /
    • 2008
  • Background: Cerebral palsy (CP) is non-progressive disorder of motion and posture. In CP patient, there are difficulties in dental treatment because of uncontrolled movement of limb and head, and conjoined disabilities such as cognitive impairment, sensory loss, seizures, communication and behavioral disturbances. It is reported that CP patients have high incidence in caries and a higher prevalence of periodontal disease. But, despite the need for oro-dental care, these patients often are unlikely to receive adequate treatment without sedation or general anesthesia because of uncontrolled movements of the trunk or head. Methods: We reviewed the 58 cases of 56 patients with CP who underwent outpatient general anesthesia for dental treatment at the clinic for the disabled in Seoul National University Dental Hospital. Results: The mean age was 19 (2-54) years. The number of male patient was 40 and that of female was 18. They all had severe spastic cerebral palsy and 22 had sever mental retardation, 15 epilepsy, 8 organic brain disorder, 1 blindness, 2 deafness and cleft palate. For anesthesia induction, 14 cases was needed physical restriction who had sever mental retardation and cooperation difficulty, but 44 cases showed good or moderate cooperation. Drugs used for anesthesia induction were thiopental (37 cases), sevoflurane (14 cases), ketamine (3 cases ) and propofol (4 cases). All patients except one were done nasotracheal intubation for airway management and 4 cases were needed difficult airway management and 1 patient already had tracheostomy tube. Mean total anesthetic time was $174{\pm}56$ min and staying time at PACU was $88{\pm}39$ min. There was no death or long term hospitalization because of severe complications. Conclusion: If general anesthesia is needed, pertinent diagnostic tests and workup about anomaly, and appropriate anesthetic planning are essential for safety.

  • PDF

Characteristics of Heat Transfer and Chemical Reaction in Reformer Tube for Fuel Reynolds Number and Burner Gas Temperature (개질관 내부 레이놀즈 수와 버너 온도에 따른 열유동 및 반응 특성)

  • Han, Jun Hee;Yoon, Kee Bong;Kim, Ji Yoon;Lee, Seong Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.69-74
    • /
    • 2015
  • The study investigated numerically the heat transfer and chemical reaction characteristics of a methane-steam reforming by using a 3-dimensional computational fluid dynamics (CFD) code (Fluent ver. 16.1). The fuel temperature and its species mole fractions were estimated for various Reynolds number in the reformer tube at different burner temperatures. The catalysts were modeled as the porous medium of nicrome in the reformer tube. We considered radiation effect as well as conduction and convective heat transfer because the methane-steam was reformed at very high temperature condition above 1000 K. For two different Reynolds numbers of 49,000 and 88,000 and the burner temperatures were in the range from 1,100 K to 1,300 K. At a low Reynolds number, the fuel temperature increased, leading to increase in hydrogen reforming. However, fuel temperature and hydrogen reforming decreased because of higher convective heat transfer from relatively low fuel temperature. Moreover, the hydrogen reforming also increased with burner temperature.

A Study on Spatial Characteristics of Post-Disaster Interim Housing - Focusing on Asian Precedents of Natural Disasters - (재난 이후 임시주거의 공간특성 연구 - 아시아지역에서 발생한 자연재난을 중심으로 -)

  • Kim, sara;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.5
    • /
    • pp.108-116
    • /
    • 2015
  • This study intends to research the spatial characteristics of Asian interim housing that accommodates sufferers pro tempore after disasters. The scope of this research covers the interim spaces used for housing people after natural disasters that occurred in Asia for the past fifteen years. Within this scope, literature review was conducted as the basis to derive the characteristics and environmental elements of interim housing, which provided the criteria to compare and evaluate cases of interim housing along with characteristic elements required of interim housing found in previous studies. According to literature review, interim housing can be classified by life-span, region, economy, climate, type, number of household, square measure, residential cost, structure/material, and service life. Within the scope of the present research, literature review showed a total of twenty-eight cases of interim housing in fifteen countries revealing a high rate of disaster occurrence in the subtropic and tropic climate of Southeast Asia. A great percentage of interim housing was used for long-term stay of over a year. The structure of interim housing varied from lightweight steel, wooden, masonry, membrane, to traditional structure and the type were divided into temporary shelter, transitional housing, temporary housing, and permanent housing. Followed by literature review, the characteristics required of post-disaster interim housing were analyzed based on previous research and case studies. The characteristics of interim housing can be divided into environmental, technological, and socio-cultural ones. Sub-characterical items according to such division include amenity, health, surroundings, structure, convenience, eco-friendliness, safety, communication, and locality. As a result of evaluation, most items met the required characteristics of interim housing, while technological characteristics such as structure and convenience varied with the types of interim housing and appeared even unnecessary in some cases. According to analysis, amenity is maintained through the structural and material characteristics of interim housing and is also facilitated by increasing number of infrastructure such as educational, sanitary, and convenience facilities provided by the governmental and organizational bodies. It is expected that this study will be utilized as preliminary data for follow-up studies that improve the environment of post-disaster interim housing suitable for domestic circumstances in environmental, technological, and socio-cultural respects.

A Study on the Interference of HF Maritime Mobile Telecommunication by the PLC (전력선통신이 단파대 해상이동통신에 미치는 영향에 관한 연구)

  • Kim Jeong-nyun;Choi Jo-cheon;Jo Hag-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.250-256
    • /
    • 2006
  • The revision of radio waves act, which took effect on July 1,2005, widened the bandwidth of PLC from $9kHz{\sim}450kHz$ to $9kHz{\sim}30MHz$. This high upper limit of frequency may cause the interference in HF wireless communications. From this point of view, the goal of this research is to suggest the estimation method of whether-or-not the interference occurs and furthermore offer countermeasures to avoid it hereafter. Ministry of Information and Communication Radio Research Laboratory(MIC-RRL)has been researching for the interference and devoting themselves to turn out how much it affects to HF wireless communications since the revision took effect. This research suggests some estimation methods with receivers, signal generators, or SINAD(Signal to Noise and Distortion) Meter which is so suitable for the RF environment that we can overcome the existing limit to the EMC environment. In addition, this research is focused on securing the environment for wireless communications by establishing the safety zone or suggesting the ways to prohibit the use of the bandwidth, which may cause serious interference, in order to minimize the effect of PLC on HF maritime mobile telecommunications.

A generation method of ASF mapping by the predicted ASF with the measured one in the Yeongil Bay (ASF 예측모델과 실측치를 이용한 영일만 해상 ASF 맵 생성기법)

  • Hwang, Sang-Wook;Shin, Mi Young;Choi, Yun Sub;Yu, Donghui;Park, Chansik;Yang, Sung-Hoon;Lee, Chang-Bok;Lee, Sang Jeong
    • Journal of Navigation and Port Research
    • /
    • v.37 no.4
    • /
    • pp.375-381
    • /
    • 2013
  • In order to establish eLoran system it needs the betterment of a receiver and a transmitter, the add of data channel to loran pulse for loran system information and the differential Loran for compensating Loran-c signal. Precise ASF database map is essential if the Loran delivers the high absolute accuracy of navigation demanded at maritime harbor entrance. In this study we developed the ASF mapping method using predicted ASFs compensated by the measured ASFs for maritime in the harbor. Actual ASF is measured by the legacy Loran signal transmitted from Pohang station in the GRI 9930 chain. We measured absolute propagation delay between the Pohang transmitting station and the measurement points by comparing with the cesium clock for the calculation of the ASFs. Monteath model was used for the irregular terrain along the propagation path in the Yeongil Bay. We measured the actual ASFs at the 12 measurement points over the Yeongil Bay. In our ASF-mapping method we estimated that the each offsets between the predicted and the measured ASFs at the 12 spaced points in the Yeongil. We obtained the ASF map by adjusting the predicted ASF results to fit the measured ASFs over Yeungil bay.