• Title/Summary/Keyword: high rise buildings

Search Result 1,539, Processing Time 0.028 seconds

Analysis of Factors Influencing Street Vitality in High-Density Residential Areas Based on Multi-source Data: A Case Study of Shanghai

  • Yuan, Meilun;Chen, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • Currently, big data and open data, together with traditional measured data, have come to constitute a new data environment, expanding new technical paths for quantitative analysis of the street environment. Streets provide precious linear public space in high-density residential areas. Pedestrian activities are the main body of street vitality. In this paper, 441 street segments were selected from 21 residential districts in high-density downtown area of Shanghai as cases, to quantitatively evaluate the influencing factors of pedestrian activities. Bivariate analysis was performed, and the results showed that street vitality was not only correlated with a highly populated environment, but also with other factors. In particular, the density of entrances and exits of residential properties, the proportion of walkable areas, and the density of retail and service facilities, were correlated with the vitality of street segments. The magnitudes of correlation between the street environmental factors and the pedestrian traffic differed across various trip purposes. Segment connectivity factors were more correlated with walking for leisure than for transportation. While public transportation factors were mainly correlated with walking for transportation, vehicular traffic factors were negatively correlated with walking for leisure.

Spatial Regeneration for Preservation of Historic Urban Features and Improvement of Living Conditions in High-density Historic Districts: Urban Renewal Design Strategies for Shanghai's Old Town

  • Huang, Na;Cai, Yongjie;Zhuang, Mingyu;Zhou, Yi;Zhou, Jun
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.9-16
    • /
    • 2021
  • Being the origin of Shanghai City, the Old Town presents a high-density spatial texture, a characteristic of local living conditions in the Shanghai context. However, the Old Town is faced with competing interests: the preservation of historic urban features and the improvement of contemporary living conditions. In view of its high density and poor living conditions, this paper focuses on two types of blocks for urban design research, and proposes two spatial regeneration strategies, as "overlapping lilong" and "texture continuity". It is expected to inherit the regional characteristics of urban space, improve the plot ratio and supplement the mix of functions, through the translation of the traditional lilong typology and the reproduction of historical streets and alleys, so as to provide operable spatial strategies and design methods for the organic renewal of Old Town and other historic districts.

Classification of Metro Station Areas Using Multi-Source Big Data: Case Studies in Beijing

  • Shuo Chen;Xiangyu Li
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.1
    • /
    • pp.63-74
    • /
    • 2023
  • Large-capacity public transportation systems, represented by urban metro lines, are the key to alleviating the significant increase in urbanization and motorization in China. But to improve the agglomeration effect of metro stations in a more accurate and targeted way requires scientific evaluation and classification of the surrounding areas of metro stations. As spatial and functional design are the core factors for urban renewal design, this study took Beijing as an example, using multi-source data to evaluate the morphology and functional composition surrounding areas of metro stations, and the Boston Consulting Group (BCG) matrix was used to classify and characterize each type of surrounding areas from morphological-functional dimensions. It shows a negative correlation of the mix-use index with the floor area ratio, and only about 20% of the areas achieve the ideal situation of high construction intensity with high mix-use diversity. Hoping to provide a reference for city managers and designers in dealing with the surrounding metro stations with different construction intensities in a more precise way.

Serviceability-oriented analytical design of isolated liquid damper for the wind-induced vibration control of high-rise buildings

  • Zhipeng Zhao;Xiuyan Hu;Cong Liao;Na Hong;Yuanchen Tang
    • Smart Structures and Systems
    • /
    • v.33 no.1
    • /
    • pp.27-39
    • /
    • 2024
  • The effectiveness of conventional tuned liquid dampers (TLDs) in controlling the wind-induced response of tall flexible structures has been indicated. However, the impaired control effect in the detuning condition or a considerably high mass cost of liquid may be incurred in ensuring the high-level serviceability. To provide an efficient TLD-based solution for wind-induced vibration control, this study proposes a serviceability-oriented optimal design method for isolated TLDs (ILDs) and derives analytical design formulae. The ILD is implemented by mounting the TLD on the linear isolators. Stochastic response analysis is performed for the ILD-equipped structure subjected to stochastic wind and white noise, and the results are considered to derive the closed-form responses. Correspondingly, an extensive parametric analysis is conducted to clarify a serviceability-oriented optimal design framework by incorporating the comfort demand. The obtained results show that the high-level serviceability demand can be satisfied by the ILD based on the proposed optimal design framework. Analytical design formulae can be preliminarily adopted to ensure the target serviceability demand while enhancing the structural displacement performance to increase the safety level. Compared with conventional TLD systems, the ILD exhibits higher effectiveness and a larger frequency bandwidth for wind-induced vibration control at a small mass ratio.

Analysis of the Wireless Communication Environment in the Narrowed Residential Space for the Fire fighting Operation (소방작전을 위한 협소거주 공간의 무선 통신 환경 분석)

  • Park, Hyun-Ju;Hong, Sang-Beom;Choi, Hyuk-Jo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.242-248
    • /
    • 2017
  • Recently, Population has been concentrated in cities due to rapid economic growth. As a result, urban buildings are becoming more dense, high-rise, and diversified. The shape of these urban buildings increases the risk of fire, accidents and crime. The narrow living space has the characteristic of the unchanged floor. In case of a fire, the living space of the narrow residence is large in the damage because the smoke diffusion rate is fast. The radio wave transmittance and transmission distance of wireless communication used in fire fighting operations vary depending on the type of building materials and buildings. Therefore, this paper analyzes the building materials and structural characteristics of the narrow residential space for efficient fire fighting operations. We have developed a communication environment solution for a narrow residential space for the optimal fire fighting operation through the measurement of the radio wave transmittance and the transmission distance of the wireless communication.

Discussion on Sustaining "Olle" without Losing Integrity of Local Identity - Focused on downtown area called Mu-geun-sung at Jeju city - (올래의 지속가능한 재생방식에 관한 연구 - 제주시 무근성 지역을 중심으로 -)

  • Yi, Yong Kyu;Yi, Yun Kyu;Jing, Li-Yuan
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2018
  • There are still a number of "olles" existing with traditional alley characteristics in the inner city of Jeju. As a matter of fact, the renovation of old buildings and the protection of alley space are facing a dilemma due to the existence of less than 4m-width-roads in the area of "Mu-geun-sung". This study examines the current status of alley space in "Mu-geun-sung" area; and puts forward to the potential possibility and limitation of alley space regeneration via exploring the applicable scheme of building agreement. In the field survey, a number of regions in inner city of Jeju witnesses the existing majority of invaluable, conventional olles. So as to grasp the feasibility in "Mu-geun-sung" area, we designs a simulating experiment to carry out the Building Agreement; and compares with the current development model in this area. Building Agreement implies to establish gradually a separation of land ownership under the existing unified development of landowners and users, thus to explore a variety of land exploitation systems by separating land ownership and right to use land. As a result, the deterioration of the street landscape results from the increase of building storey numbers. The damages to the surrounding environment brought by the newly built buildings will be minimized as well as keeping the maximum building volume rate. Obviously, these measures will alleviate infringement to the traditional residential sunlight and privacy space effectively, and reduce the pressure from high-rise buildings to the alley space, so that the landscape of the alley will enhance to form a more comfortable alley environment.

Optimal Supply Scheme of Solar Hot Water Heating Systems for the Apartment Complexes (공동주택용 태양열 급탕시스템 최적공급 방안 해석연구)

  • Lee, Chul-Sung;Park, Ja-Son;Park, Jae-Wan;Shin, U-Cheul;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.245-250
    • /
    • 2008
  • This study is on the availability of solar thermal energy in Korean high-rise apartment complex depending on the installation type of solar collectors to roof or facade of building. Firstly, solar access evaluation on the roof and the facade of apartment buildings was carried out. The total thermal load of each apartment unit and building was investigated and matched with the energy which was produced by solar thermal systems on the facade. The considered layout patterns of apartment buildings were '一type', 'alternative 一type', 'ㄱtype' and 'ㅁtype' and that was analyzed in prior studies. Extensive dynamic hourly energy simulations with the solar thermal system were Performed with the TRNSYS of SEL. We assumed that the apartment complex is composed of 9 buildings and located in Daejeon. The collectors are the heat-pip evacuated tube collectors and the number of collectors are 45 tubes We assumed that the collectors are installed on the balcony of each unit and the angle of incilnation is $90^{\circ}$. As a result, the supply amount of solar thermal systems is about 4,850,086kJ/hr and the solar fraction is about 66%. The solar fraction according to each azimuth is about 66% on the south, 62% on the south-east $30^{\circ}$ and 56% on the south-east $60^{\circ}$. So, we quantitatively got a line on the optimal azimuth for installing the solar thermal systems. The solar fraction has differences from 5% to 15% of each floor, 6th, 12th and 20th and those tendencies are same in analyzed each 4 types of the apartment complexes.

  • PDF

Human-Induced Vibrations in Buildings

  • Wesolowsky, Michael J.;Irwin, Peter A.;Galsworthy, Jon K.;Bell, Andrew K.
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.1
    • /
    • pp.15-19
    • /
    • 2012
  • Occupant footfalls are often the most critical source of floor vibration on upper floors of buildings. Floor motions can degrade the performance of imaging equipment, disrupt sensitive research equipment, and cause discomfort for the occupants. It is essential that low-vibration environments be provided for functionality of sensitive spaces on floors above grade. This requires a sufficiently stiff and massive floor structure that effectively resists the forces exerted from user traffic. Over the past 25 years, generic vibration limits have been developed, which provide frequency dependent sensitivities for wide classes of equipment, and are used extensively in lab design for healthcare and research facilities. The same basis for these curves can be used to quantify acceptable limits of vibration for human comfort, depending on the intended occupancy of the space. When available, manufacturer's vibration criteria for sensitive equipment are expressed in units of acceleration, velocity or displacement and can be specified as zero-to-peak, peak-to-peak, or root-mean-square (rms) with varying frequency ranges and resolutions. Several approaches to prediction of floor vibrations are currently applied in practice. Each method is traceable to fundamental structural dynamics, differing only in the level of complexity assumed for the system response, and the required information for use as model inputs. Three commonly used models are described, as well as key features they possess that make them attractive to use for various applications. A case study is presented of a tall building which has fitness areas on two of the upper floors. The analysis predicted that the motions experienced would be within the given criteria, but showed that if the floor had been more flexible, the potential exists for a locked-in resonance response which could have been felt over large portions of the building.

The Application of Post-tensioned Slab System to Tall Buildings (초고층 건축물의 포스트텐션 슬래브 시스템 적용)

  • Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.879-882
    • /
    • 2008
  • The market of Korea of post-tension system for building is growing up since 2000 and many engineers and construction companies show interest in it. This paper introduces the structure system and construction of post-tension tall buildings including recent trend in the industry of post-tension system for buildings in Korea and the point to be considered when design post-tensioned tall building. Park Polis is composed of two towers of 39 stories with a level to the top of the roof +144m and is currently under construction at Ulsan in Korea. This building designed as the unbonded post-tension floor system and will be the tallest and first high-rise post-tensioned building in Korea. The structural system is composed of the flat slabs, perimeter columns and core walls. At first, this building had designed as regular RC flat slab with perimeter beams. However, floor structure system was reconsidered because the construction company wants to improve efficiency of construction. As a result, the floor system of PARK POLIS re-designed as PT flat slab.

  • PDF

A Study of Subspacing Strategy for Service Applications in Indoor Space (실내공간 응용 서비스를 위한 공간분할 방법에 관한 연구)

  • Kang, Hye Young;Jung, Hyo-jin;Lee, Jiyeong
    • Spatial Information Research
    • /
    • v.23 no.3
    • /
    • pp.113-122
    • /
    • 2015
  • Recently, according to developing advanced construction technologies, buildings has been enlarged such as high-rise buildings or complex buildings associated with underground facilities. The number of indoor activity population has increased very quickly. Because of that, technical requirements for Indoor location based service (Indoor LBS) also have been increased. Although indoor networks have to be constructed for efficient LBSs in indoor space based on OGC IndoorGML, it is not suitable for large and complex space to apply the simple network structure to constructing indoor navigation networks. The indoor navigation network has to be constructed according to logical, physical, and functional constraints for indoor space. In order to do that, subspacing methods are required to partition large and complex indoor space into proper size of subspace. In this paper, we proposed the basic requirements of subspacing in indoor space for creating efficient indoor network, as well the work process of subspacing in indoor space.