• Title/Summary/Keyword: high pressure water jet

Search Result 79, Processing Time 0.024 seconds

Development of the Air-lifting & Suction-pumping System to Remove the Noxious Deposit in the Underwater (수중 유해성 유기퇴적물의 수거를 위한 Air-lifting & Suction-pumping System 개발)

  • Kim, Seoung-Gun;Song, Do-Sung;Kang, Mun-Kyu;Lee, Sang-Moo;Choi, Young-Chan;Ko, Yu-Bong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.251-255
    • /
    • 2002
  • Eutrophic matters accumulated on the bottom of sea, river and lake cause red tide phenomenon in ocean and outbreak green algae in river and lake. Systems are developed to remove the noxious deposit. But the existing systems remove not only the eutrophic matters but also natural materials, sand, pebbles etc. that should remain at the bottom. This paper describes a new system that can safely, and economically take away the noxious deposit in underwater. High pressure water jet is used to induce vortices in the triangular suction section, and air-lifting pump to lift up the deposit. The mixture of the water and deposit is filtered through the drum filters. An under camera shows the under water situation along the moving direction of the system that is controlled by a remote operator. This remote controlled moving system obliterate the necessity of the diver that usually costs high. The experimental results show the effectiveness of the suggested system.

  • PDF

Experiments of Micro Jet Injection for Bio-Medical Application (바이오 분야 적용을 위한 마이크로 젯 인젝션 실험)

  • Ham, Young-Bog;An, Byeung-Cheol;Trimzi, Mojiz Abbas;Kim, Jong-Dae;Lee, Gi-Tae;park, Jung-Ho;Yun, So-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.681-687
    • /
    • 2016
  • It is essential for micro jet injectors in the biomedical sector to operate under high pressure. High pressure injection, however, is accompanied by high volumes. On/Off valves that can be operated at high speeds have been used to address this problem. In this research, piezoelectric actuators which have a response frequency of the order of hundreds of kilohertz were used as the On/Off valve and experiments were applied. Researchers developed a controller to precisely manipulate the piezoelectric valve with various waveforms. They also fabricated five types of nozzles to consider the effect of nozzle type on injection. This allowed researchers to manipulate and confirm factors that can affect the injection volume and force. Results of this experiment have shown how to decrease the injection volume and increase the injection force. and it is predicted that the optimized injection volume and force value can be determined depending on the skin type.

A Study on the Ultrasonic Conditioning for Interlayer Dielectic CMP (층간절연막 CMP의 초음파 컨디셔닝 특성에 관한 연구)

  • 서헌덕;정해도;김형재;김호윤;이재석;황징연;안대균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.854-857
    • /
    • 2000
  • Chemical Mechanical Polishing(CMP) has been accepted as one of the essential processes for VLSI fabrication. However, as the polishing process continues, pad pores get to be glazed by polishing residues, which hinder the supply of new slurry. This defect makes removal rate decrease with a number of polished wafer and the desired within-chip planarity, within wafer and wafer-to-wafer nonuniformity are unable to be achieved. So, pad conditioning is essential to overcome this defect. The eletroplated diamond grit disk is used as the conventional conditioner, And alumina long fiber, the .jet power of high pressure deionized water and vacuum compression are under investigation. But, these methods have the defects like scratches on wafer surface by out of diamond grits, subsidences of pad pores by over-conditioning, and the limits of conditioning effect. To improve these conditioning methods. this paper presents the Characteristics of Ultrasonic conditioning aided by cavitation.

  • PDF

Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water (고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구)

  • Lee, Sanghyup;Yoshimasa, Watanabe;Lee, Seockheun;Ahn, Kyuhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit (공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Youngmin;Kim, Se-Young;Kim, Myeoung-Joon;Kim, Hojoong;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

The Moving Speed of Typhoons of Recent Years (2018-2020) and Changes in Total Precipitable Water Vapor Around the Korean Peninsula (최근(2018-2020) 태풍의 이동속도와 한반도 주변의 총가강수량 변화)

  • Kim, Hyo Jeong;Kim, Da Bin;Jeong, Ok Jin;Moon, Yun Seob
    • Journal of the Korean earth science society
    • /
    • v.42 no.3
    • /
    • pp.264-277
    • /
    • 2021
  • This study analyzed the relationship between the total precipitable water vapor in the atmosphere and the moving speed of recent typhoons. This study used ground observation data of air temperature, precipitation, and wind speed from the Korea Meteorological Administration (KMA) as well as total rainfall data and Red-Green-Blue (RGB) composite images from the U.S. Meteorological and Satellite Research Institute and the KMA's Cheollian Satellite 2A (GEO-KOMPSAT-2A). Using the typhoon location and moving speed data provided by the KMA, we compared the moving speeds of typhoon Bavi, Maysak, and Haishen from 2020, typhoon Tapah from 2019, and typhoon Kong-rey from 2018 with the average typhoon speed by latitude. Tapah and Kong-rey moved at average speed with changing latitude, while Bavi and Maysak showed a significant decrease in moving speed between approximately 25°N and 30°N. This is because a water vapor band in the atmosphere in front of these two typhoons induced frontogenesis and prevented their movement. In other words, when the water vapor band generated by the low-level jet causes frontogenesis in front of the moving typhoon, the high pressure area located between the site of frontogenesis and the typhoon develops further, inducing as a blocking effect. Together with the tropical night phenomenon, this slows the typhoon. Bavi and Maysak were accompanied by copious atmospheric water vapor; consequently, a water vapor band along the low-level jet induced frontogenesis. Then, the downdraft of the high pressure between the frontogenesis and the typhoon caused the tropical night phenomenon. Finally, strong winds and heavy rains occurred in succession once the typhoon landed.

Enhancement of Nitric Oxide with nonthermal plasma jet and its effect on Escherichia coli inactivation and various type of cancer cell

  • Shaw, Priyanka;Kumar, Naresh;Attri, Pankaj;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.230.2-230.2
    • /
    • 2016
  • A new approach for antimicrobial is based on the overproduction of reactive nitrogen species (RNS), especially; nitric oxide (NO) and peroxinitrite ($ONOO^-$-) are important factors to deactivate the bacteria. Recently, non-thermal atmospheric pressure plasma jet (APPJ) has been frequently used in the field of microbial sterilization through the generation of different kinds of RNS/ROS species. However, in previous study we showed APPJ has combine effects ROS/RNS on bacterial sterilization. It is not still clear whether this bacterial killing effect has been done through ROS or RNS. We need to further investigate separate effect of ROS and RNS on bacterial sterilization. Hence, in this work, we have enhanced NO production, especially; by applying a 1% of HNO3 vapour to the N2 based APPJ. In comparison with nitrogen plasma with inclusion of water vapour plasma, it has been shown that nitrogen plasma with inclusion of 1% of HNO3 vapour has higher efficiency in killing the E. coli and different type of cancer cell through the high production of NO. We also investigate the enhancement of NO species both in atmosphere by emission spectrum and inside the solution by ultraviolet absorption spectroscopy. Moreover, qPCR analysis of oxidative stress mRNA shows higher gene expression. It is noted that 1% of HNO3 vapour plasma generates high amount of NO for killing bacteria and cancer cell killing.

  • PDF

Nozzle Condition Monitoring System for Abrasive Waterjet Process (연마재 워터젯을 위한 노즐상태 모니터링 시스템 설계)

  • Kim, Jeong-Uk;Kim, Roh-Won;Kim, Chul-Min;Kim, Sung-Ryul;Kim, Hyun-Hee;Lee, Kyung-Chang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.817-823
    • /
    • 2020
  • In recent, the machining of difficult-to-cut materials such as titanium alloys, stainless steel, Inconel, ceramic, glass, and carbon fiber reinforced plastics (CFRP) used in aerospace, automobile, medical industry is actively researched. Abrasive waterjet is a non-traditional processing method in which ultra-high pressure water and abrasive particles are mixed in a mixing chamber and shoot out jet through a nozzle, and removed by erosion due to collision with a material. In particular, the nozzle of the abrasive waterjet is one of the most important parts that affect the machining quality as with a cutting tool in general machining. It is very important to monitor the condition of the nozzle because the workpiece is uncut or the surface quality deteriorates due to wear, expanding of the bore, damage of the nozzle and clogging of the abrasive, etc. Therefore, in this paper, we propose a monitoring system based on Acoustic Emission(AE) sensor that can detect nozzle condition in real time during AWJ processing.

A Study on the Deep Kerfing Technique in Rock Using High Pressure Water Jet (워터젯을 이용한 암석의 슬롯절삭에 관한 연구)

  • 최병희;양형식
    • Explosives and Blasting
    • /
    • v.19 no.3
    • /
    • pp.105-113
    • /
    • 2001
  • 채석, 굴착, 가공과 같은 워터젯 응용분야에서 대상재료에 깊은 홈(kerf)을 절단할 수 있는 실험실용 회전식 슬로터(slotter)를 제작하여 암석을 대상으로 워터젯 시스템의 절단효율을 시험하였다. 고압펌프는 유율 7.5 l/min, 압력 379 MPa, 용량 75 kW급의 JETPAC을 주로 사용하였고, 암석시료는 화강석인 제천석, 거창석을 사용하였다. 시험과정에서는 물과 연마재 투입에 의한 절단 및 진동식 슬로터에 의한 슬롯절단 기초시험을 먼저 수행하고, 그 결과를 토대로 회전식 슬로터에 의한 절단시험을 실시하였다. 순수한 물에 의한 시험의 결과 고압수류의 토출압력은 절단심도에 정비례하였고, 노즐의 이송속도는 이차함수 형태의 반비례 관계를 보였다. 연마재 투입시험에서는 순수한 물에 의한 경우에 비해 연마재로 인한 충격력의 증가로 절단심도가 크게 증가하였는데, 유사한 조건하에서 3~5배 이상의 절단심도의 증가를 보였다. 진동식 슬로터에 의한 슬롯절삭에서는 생성된 슬롯의 내벽면이 바닥으로 갈수록 좁아짐으로써 넓은 폭의 슬롯형성은 가능하나 절삭심도가 제한되었다. 회전식 슬로터에 의한 시험에서 생성된 슬롯들은 평균 22 mm의 폭으로 내벽면이 바닥까지 서로 평행하여 깊은 심도까지 비트진입이 가능하였다. 절단율은 16~32 mm/sec의 속도범위에서 $40~160{\;}\textrm{mm}^2/sec$로 나타났다. 한편, 최대유율 24 l/min의 HUSKY S-200 펌프에 의한 시험결과 JETPAC 펌프에 비해 1.13~3.47 배의 절단심도를 보였다

  • PDF

A Study on Interlayer Dielectric CMP Using Diamond Conditioner (다이아몬드 컨디셔너를 이용한 ILD CMP에 관한 연구)

  • 서헌덕;김형재;김호윤;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.86-89
    • /
    • 2003
  • Chemical Mechanical Planarization(CMP) has been accepted as the most effective processes for ultra large scale integrated (ULSI) chip manufacturing. However, as the polishing process continues, pad pores get to be glazed by polishing residues, which hinder the supply of new slurry. And pad surface is ununiformly deformed as real contact distance. These defects make material removal rate(MRR) decrease with a number of polishied wafer. Also the desired within-chip planarity, within wafer non-uniformity(WIWNU) and wafer to wafer non-uniformity(WTWNU) arc unable to be achieved. So, pad conditioning in CMP Process is essential to overcome these defects. The eletroplated or brazed diamond conditioner is used as the conventional conditioning. And. allumina long fiber, the jet power of high pressure deionized water, vacuum compression. ultrasonic conditioner aided by cavitation effect and ceramic plate conditioner are once used or under investigation. But. these methods arc not sufficient for ununiformly deformed pad surface and the limits of conditioning effect. So this paper focuses on the characteristics of diamond conditioner which reopens glazed pores and removes ununiformly deformed pad away.

  • PDF