• 제목/요약/키워드: high pressure discharge

검색결과 511건 처리시간 0.028초

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

안와내벽외향골절의 비내시경적정복술에 있어 중비도상악동절개술의 장점 (Advantage of Middle Meatal Antrostomy in Transnasal Endoscopic Reconstruction of Medial Orbital Blow-out Fracture)

  • 김순흠;이수향;최현곤;신동혁;엄기일;김보형
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.735-740
    • /
    • 2007
  • Purpose: Blowout fracture is an outward fracture of the orbital wall. That usually occurs at inferior or medial wall of the orbit. The main pathophysiology is high intraocular pressure derived from impact of trauma. Among the four orbital wall, the medial wall is thinnest and most vulnerable to trauma. Many kinds of methods were introduced for correction of medial orbital wall fracture. Recently, transnasal endoscopic reconstruction methods were widely used. Endoscopic methods had many advantages. However, we experienced some cases of postoperative maxillary sinusitis. This study was planned to find out the effectiveness of middle meatal antrostomy after endoscopic reconstruction of medial orbital wall fracture. Methods: This study was retrospective analysis of 28 patients who underwent transnasal endoscopic repair of medial orbital wall fracture. The 18 male and 10 female patients were ranged from 17 to 57 years of age(mean, 30.9 years). Among 28 patients, randomly selected 17 patients underwent middle meatal antrostomy as additional procedure by the same surgeon. After at least 12 months of follow-up period, we examined the nasal symptom, endoscopic and CT findings. Results: One patient complained of nasal obstruction in middle meatal antrostomy group and four patients complained nasal symptoms in non middle meatal antrostomy group. On the endoscopic findings, three patients of non middle meatal antrostomy group had continuous nasal discharge. But middle meatal antrostomy group had no abnormal endoscopic findings. The abnormal CT finding(abnormal mucosal hypertrophy) were detected in four patient of non middle meatal antrostomy group. There were no abnormal CT findings in middle meatal antrostomy group. The data were statistically significant at comparative study. Conclusion: Authors think that the middle meatal antrostomy has some advantages as a additional procedure of endoscopic reconstruction of medial orbital wall fracture. Especially, it is good at preventing postoperative maxillary sinusitis. But, more larger group and strict application of disease entity are need for correct evaluation of middle meatal antrostomy effect.

운동용 속옷의 착용효과 -소재별 발한량과 체중감량을 중심으로- (The Wearing Effect of Sport Underwear -Focusing on the Loss of Weight and Amount of Sweat according to the Materials-)

  • 나미향;김미선;정복희
    • 한국생활과학회지
    • /
    • 제11권3호
    • /
    • pp.273-285
    • /
    • 2002
  • Three materials for sport underwear were manufactured by order for study, and among them, suitable material in order to perform an experiment on the effect of wearing was adopted. The results are as follows: The result of wearing an experimental clothes for sports manufactured as a foundation-type underwear for sports showed that if the same compositional materials were applied, laminating material had higher rate than that of others in the amount of sweat. Concerning relative humidity in clothes and the amount of sweat absorbed in clothes among the two kinds of materials which were produced by laminate, material 2(nylon+modal) was statistically exerts higher influence on the amount of sweat. The humidity in clothes keeps the optimal condition of 59.8%, and breast part showed the highest relative humidity. The material 2(nylon+modal) showed the highest comfortableness, the sense of warmth, humidity and voluminousness, and the sense of pressure. Follow-up survey revealed that in case of material 2, higher amount of sweat than that of the group objects in its early phase, and the amount of sweat varies from individuals. The temperature in clothes of folded parts of experimental clothes and maximum surface temperature was equivalent to that of average skin. With the lapse of time, the weight decreased of 11.03% in maximum, and 3.12% in minimum. The amount of change in the girth was greater in part of body frame than that of limbs, and especially, navel and waist part showed high decrease, and upper breast, breast and the largest part of abdomen showed relatively low decrease. The above experiment revealed that materials for suitable to the underwear for sports for loss of weight by an exercise should be made of doubled-nylon and modal, along with the laminate processing, which heightens the amount of sweat. Thus, wearing an experimental wear gave satisfaction in the view of the beauty of appearance as it did not discharge flowing secretion to the outside at the time of exercise.

  • PDF

Analysis of Air Discharge and Disused Air Filters in Radioisotope Production Facility

  • Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.156-161
    • /
    • 2016
  • When air discharged from a radioisotope production facility is contaminated with radiation, the public may be exposed to radiation. The objective of this study is to manage such radiation exposure. We measured the airborne radioactivity concentration at a 30 MeV cyclotron radioisotope production facility to assess whether the exhaust gas was contaminated. Additionally, we investigted the radioactive contamination of the air filter for efficient air purification and radiation safety control. To measure the airborne radiation concentration, specimens were collected weekly for 4 h after the beginning of the radioisotope production. Regarding the air purifier, five specimens were collected at different positions of each filter-pre-filter, high-efficiency particulate air filter, and charcoal filter-installed in the cyclotron production room. The concentrations of F-18, I-123, I-131, and Tl-201 generated in the radioiodine production room were $13.5Bq/m^3$, $27.0Bq/m^3$, $0.10Bq/m^3$, and $11.5Bq/m^3$, respectively; the concentrations of F-18, I-123, and I-131 produced in the radioisotope production room were $0.05Bq/m^3$, $16.1Bq/m^3$, and $0.45Bq/m^3$, correspondingly; and those of F-18, I-123, I-131, and Tl-201 generated in the accelerator room were $2.07Bq/m^3$, $53.0Bq/m^3$, $0.37Bq/m^3$, and $0.15Bq/m^3$, respectively. The maximum radiation concentration of I-123 generated in the radioiodine production room was 1,820 Bq/g, which can be disposed after 2 days. The maximum radiation concentration of Tl-202 generated in the radioisotope production room was 205 Bq/g, and this isotope must be stored for 53 days. The I-123 generated in the radioiodine production room had a maximum concentration of 1,530 Bq/g and must be stored for 2 days. The maximum radiation concentration of Na-22 generated in the radioisotope production room was 0.18 Bq/g and this isotope must be disposed after 827 days. To manage the exhaust, the efficiency of air purification must be enhanced by selecting an air purifier with a long life and determining the appropriate replacement time by examining the differential pressure through systematic measurements of the airborne radiation contamination level.

미세입자(微細粒子)를 함유(含有)한 슬러지의 고효율(高效率) 탈수(脫水) 연구 (A study for High Efficiency Dewatering of Sludge Contained Fine Particles)

  • 이정언;이재근
    • 자원리싸이클링
    • /
    • 제15권4호
    • /
    • pp.36-43
    • /
    • 2006
  • 입자의 크기가 $5{\mu}m$ 이하인 미세입자를 함유한 안료 슬러지를 탈수하여 케이크화될 때 기공의 크기가 매우 작아 물의 배출이 어려운 특성이 있다. 기존의 외부가압력으로 탈수하는 기계식 탈수방법으로 탈수하기는 어렵다. 본 연구는 케이크 층에 저온 열을 인가하여 케이크 충의 기공으로부터 물을 원활하게 배출하여 탈수율을 향상시키고자 하는 연구이다. 케이크 층에 일정한 온도를 공급 할 수 있는 Piston형 열 탈수장치를 구축하여 미세 안료 입자 200g에 대하여 탈수 실험을 수행한 결과 여액량은 176.8g, 케이크 무게는 19.4g, 케이크 두께는 4.2mm로 측정되었으며, 함수율은 47wt%이며 면적당 건조 입자의 잔류량(여과 속도)은 $2.1DS\;m^{2}{\cdot}cycle$로 분석되었다. 이 결과는 기존의 기계식 탈수 방법에 의한 결과에 비하여 여액량은 증가하였으며, 케이크 무게와 두께는 감소하였고 탈수속도는 증가하였다. 그리고 함수율은 약 30%감소하여, 전반적으로 탈수율이 매우 향상되는 결과를 도출하였다. 그 이유는 케이크 층에 열을 인가함으로서 케이크 기공에 작용하는 내부 증발압으로 인해 물이 케이크 충으로부터 원활하게 배출되었기 때문이다. 따라서 본 연구는 미세 입자를 함유한 슬러지의 감량화를 위한 고효율 탈수 시스템 구축에 있어 매우 유용한 기술로 평가된다.

도로공사 이수식 쉴드 TBM 굴착토 및 필터케이크 재활용방안 연구 (A study for recycling plan of excavated soil and filter cake of slurry shield TBM for road construction)

  • 남성민;박서영;안병철
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.599-615
    • /
    • 2022
  • 한강과 같은 하저지반을 안전하게 굴착하기 위해서는 고수압 막장면에 대응할 수 있는 이수식 쉴드 TBM 공법을 적용한다. 이수식 쉴드 TBM 공법은 지하철 프로젝트에 널리 활용되어 왔는데 도심지 지하철 공사는 지하에서 연결되기 때문에 굴착토를 대부분 전량 사토해왔으며 필터케이크(벤토나이트)도 폐기물처리를 했다. 이와 달리 도로공사는 절성토의 최적화를 위해 굴착되어 나온 토석을 외부로 반출하는 것이 아니고 대부분 성토재로 활용하는 특징이 있어 굴착토의 활용방안이 프로젝트 성공의 중요한 요소가 된다. 이수식 쉴드 TBM 공법에서 굴착토는 이수재로 사용하는 벤토나이트와 굴착된 토사, 풍화암, 연경암 등이 섞여서 배니관을 통해 이수처리플랜트로 운송되면 이수처리플랜트에서 처리과정을 거쳐 크기별로 분리 배출된다. 이러한 굴착토 중 세립질의 토사는 필터케이크와 함께 폐기되어 왔으나 그 성분에 독성이 없고 조립토와 적정 비율로 혼합하여 사용하면 성토재의 품질기준을 만족할 수 있어 그 활용방안에 대한 연구를 수행하였다. 본 연구는 이수식 쉴드 TBM 공법의 굴착토의 활용에 있어 제도적·기술적 기준을 고찰하여 필터케이크와 골재를 도로공사의 성토재로 활용하는 방안을 도출하였다. 벤토나이트는 몬모릴로나이트로 구성된 점토이며 터널 원지반의 굴착토 또한 독성이 없는 상태로 이를 폐기물 처리하는 것은 사회적 비용이 낭비될 수 있기에 오히려 귀중한 자원으로 재활용하여 향후 이수식 쉴드 TBM 프로젝트를 수행하는 지하공간 개발사업에 도움이 되고자 기대한다.

주사기를 이용한 상악동 거상술 시 발생한 실신 및 종격동기종에 관한 증례보고 (Syncope and pneumomediastinum during the maxillary sinus elevation with an air-syringe: a case report)

  • 김수완;이종근;송지영
    • 구강회복응용과학지
    • /
    • 제37권3호
    • /
    • pp.171-176
    • /
    • 2021
  • 종격동기종은 치과 영역에서 매우 드물고 잠재적으로 위험한 합병증이다. 이의 흔한 원인으로는 핸드피스와 고압 공기/물 주사기를 사용하는 발치, 근관치료, 잇몸 밑 치은연하 소파술 등이 있다. 본 증례는 임플란트 식립을 위한 전 치료로 주사기를 이용하여 상악동에 골이식을 시행받은 61세 여자에게서 발생한 대량의 종격동기종과 피하기종의 증례이다. 환자는 치료 도중 갑작스럽게 발생한 구강 통증과 함께 의식 소실이 발생하였고, 응급실로 전원 되었다. 영상학적 검사상 종격동기종과 함께 얼굴과 목부위 전체에 피하기종이 발견되었다. 예방적 항생제, 산소 흡입, 금식 등의 보존적 치료가 이루어졌고, 합병증 없이 7일 만에 퇴원하였다. 환자의 실신은 시술 중 상악동 천공 후 과량의 공기유입으로 인해 발생한 종격동기종에 의해 순간적인 강한 흉부 압박으로 혈압 감소와 통증 쇽에 의한 것으로 생각된다. 치과 치료 중 환자가 의식을 잃었다면 기도 폐쇄의 위험성이 있기 때문에 종격동기종을 즉각적으로 감별하고 치료해야 한다.

Landsat 위성 영상으로부터 Modified U-Net을 이용한 백두산 천지 얼음변화도 관측 (Observation of Ice Gradient in Cheonji, Baekdu Mountain Using Modified U-Net from Landsat -5/-7/-8 Images)

  • 이어루;이하성;박순천;정형섭
    • 대한원격탐사학회지
    • /
    • 제38권6_2호
    • /
    • pp.1691-1707
    • /
    • 2022
  • 한반도와 중국 경계에 위치한 백두산의 칼데라호인 천지호는 계절에 따라 해빙과 결빙을 반복한다. 천지 아래에는 마그마 챔버가 존재하며 마그마 챔버의 변화에 의해 온천수의 온도 및 수압 변화와 같은 화산 전조현상이 발생한다. 이에 따라, 천지호 내에서 다른 부분보다 해빙이 빠르며 결빙기에도 늦게 얼며 물표면 온도가 높은 이상지역이 존재하게 된다. 해당 이상지역은 온천수 방출 지역으로, 이상지역의 얼음변화도 값을 통해 화산활동을 모니터링 할 수 있다. 그러나 지리적, 정치적 그리고 공간적 문제로 천지의 이상지역을 주기적으로 관측하기에는 한계가 존재한다. 따라서 본 연구에서는 Landsat -5/-7/-8 광학위성영상으로부터 Modified U-Net 회귀모델을 이용하여 이상지역내의 얼음변화도를 정량적으로 관측하였다. 1985년 1월 22일부터 2020년 12월 8일까지 이상지역을 갖는 83장의 Landsat 영상의 Visible and Near Infrared (VNIR)대역을 활용하였다. 얼음 변화도를 정량적으로 관측을 위해 VNIR대역에서 수체와 얼음과의 상대적인 분광반사도를 활용하여 새로운 데이터를 만들었다. 가시광선대역과 근적외선 대역이 가지고 있는 정보를 최대한 유지하기 위해 2개의 인코더를 가진 U-Net에 적용하여 얼음변화도를 관측하였으며 Root Mean Square Error (RMSE) 140, 상관계수 0.9968의 높은 예측 성능을 보여주었다. 따라서 Modified U-Net을 활용하면 추후 Landsat 영상으로부터 얼음변화도 값을 높은 정확도로 관측하므로 백두산 화산활동을 모니터링하는 방법 중 하나로 사용될 수 있으며, 다른 화산 모니터링 기법과 더불어 활용한다면 더욱 정밀한 화산감시체계 구축이 가능할 것이다.

승모판 수술 후 동율동 회복에 관한 임상분석 (A Clinical Analysis on the Restoration of Sinus Rhythm Following Mitral Valve Surgery)

  • 백완기;심상석;김현태;조상록;진성훈
    • Journal of Chest Surgery
    • /
    • 제32권4호
    • /
    • pp.347-352
    • /
    • 1999
  • 승모판막 질환에 흔히 동반되는 심방세동은 판막수술 후 종종 동율동으로 전환되어지는데 수술 후 동율동의 유지는 술후 불안정한 혈역학을 보이는 환자의 회복에 매우 중요할 영향을 미칠 뿐 아니라 술후 혈전색전증의 발생 빈도를 떨구어 주는 것으로 알려져 있다. 저자들은 1986년 6월부터 1996년 12월까지 성남 인하병원 흉부외과에서 시행된 후천성 판막질환 환자에서 승모판막 수술이 포함된 환자 중 184례를 대상으로 술전과 술후 심장율동의 양상 및 변화를 의무기록을 중심으로 후향적으로 관찰 분석하여 술후 동율동으로의 전환과 이의 유지에 관련인자를 규명하고자 하였다. 술전 율동이 심방세동이었던 환자 139례 중 술후 54례가 술후 동율동으로 전환되어 38.8%의 전환율을 보였으나 퇴원시를 기점으로 41례의 환자에서 다시 심방세동이 재발하여 75.9%의 재발율을 보였다. 심방세동이 재발한 환자들의 평균 동율동 유지기간은 8.2$\pm$5.9 일이었다. 또한 만기추적시 15례의 환자만이 동율동을 유지하고 있었으며 평균 추적기간은 84.4$\pm$34.7개월이었다. 환자의 연령 및 증상의 기간과 술전 심방세동의 기간, 좌심방 크기 및 술 전 폐동맥압이 술후 동율동의 유지에 관련인자로 생각된 반면, 술전 심방세동의 기간 및 박출계수만이 심방세동 재발의 위험인자로 생각되었다. 이상의 결과, 술후 동율동으로의 전환 및 유지의 빈도를 높이기 위하여는 조기수술이 강력히 요망되며, 더 나아가 본 연구의 높은 심방세동의 재발율이 \ulcorner사하는 바와 같이, 판막수술에 더불어 심방세동에 대한 적극적인 수술요법이 필요할 것으로 생각되어진다.ner1례등이 있었다. 결과: 수술사망은 2례로 조기사망률은 6.7%였다. 수술생존자 28명중 4명은 장기추적관찰이 불가능하였으며, 총 2091환자.월(평균 74.7$\pm$68.4개월, 최장 187개월)동안 관찰하였다. 이 기간중 판막의 혈전, 혈전색전증 및 항응고치료에 따른 출혈등의 합병증은 없었으나, 조직판막을 이용한 10례중 8례에서 술후 평균 87.1$\pm$23.6개월에 판막기능부전으로 재수술하였으며(이중 2례는 타 병원에서 수술함), 기계판막을 치환한 1례에서 판막주위누출과 감염으로 술후 3개월째 재수술하였다. 재수술시 사망례는 없었다. 만기사망은 1례로 방실중격결손증 교정술후 잔존 승모판폐쇄부전으로 승모판치환술을 받은 7세환아로 판막치환술후 4개월에 확장성심근염으로 사망하였다. 조직판막의 경우 생명표분석에 의한 판막실패가 없는 장기누적률은 6년째 75.0%, 7년째 50.0%, 8년째 12.5%의 기록을 보여 술후 6년에서 8년에 걸쳐 격감하는 양상을 보였다. 수술사망 2례를 제외한 28명의 장기생존률을 Kaplan-Meiyer법에 의해 분석하였을때 4개월째 생존률이 96.0%로 그 이후로는 사망례가 없었다. 결론:이상의 결과로 보아 소아 심장판막치환술은 비교적 안전하고, 술후 적절한 추적관찰이 행해질 경우 항응고요법에 따른 합병증은 거의 없으나, 5세이하 소아나 판막치환술 이전에 심장수술을 한 경우는 위험도가 여전히 높은 것으로 사료된다. 지표들 면에서 통계학적으로 차이가 없고(p>0.05), 육안적으로 광배근을 관찰하였을 때 그룹 A에서는 광배근의 유착 및 염증소견이 모두에서 있었고 그중 2마리에서는 광배근의

  • PDF

뇌졸중환자(腦卒中患者) 161례(例)에 대(對)한 임상적(臨床的) 고찰(考察) (Clinical Observation for the 161 Cases of CVA)

  • 강명석;전찬용;박종형
    • 대한한의학회지
    • /
    • 제16권2호
    • /
    • pp.17-35
    • /
    • 1995
  • 연구배경(硏究背景) 및 목적(目的): 국내(國內) 대부분(大部分)의 한방병원(韓方病院)에서 많은 수의 환자(患者)가 중풍(中風)으로 입원(入院)하고 있다. 이에 한방병원(韓方病院)을 찾고 있는 중풍환자(中風患者)에 대한 임상적(臨床的) 통계분석(統計分析)과 더불어 앞으로 나아가야 할 방향(方向)등에 대해 많은 연구(硏究)가 필요(必要)할 것으로 여겨져 본 연구(硏究)를 시작(始作)하였다. 대상(對象) 및 방법(方法): 1994년 1월(月) 1일(日)부터 동년(同年) 12월(月) 31일(日) 까지 경원대학교(暻園大學校) 부속(附屬) 한방병원(韓方病院) 순환기내과(循環器內科)에 Brain CT나 MRI상(上) 뇌혈관질환(腦血管疾患)으로 진단(診斷)받거나, 임상적(臨床的) 증상(症狀)으로 뇌졸중(腦卒中)으로 진단(診斷)받은 161예(例)의 환자(患者)를 대상(對象)으로 조사(調査)하였다. 결과(結果) 및 결론(結論): 1. 뇌졸중(腦卒中)의 종류별(種類別) 빈도(頻度)에서 뇌경색(腦梗塞)이 가장 많았으며 뇌출혈(腦出血), 지주막하출혈(蜘蛛膜下出血), 고혈압성뇌증(高血壓性腦症), 일과성뇌허혈발작(一過性腦虛血發作)의 순(順)이었다. 2. 선행질환(先行疾患)은 고혈압(高血壓)이 가장 많았으며, 당뇨(糖尿)도 많은 예(例)에서 나타났다. 3. 일반적(一般的)인 통례(通例)와는 달리 겨울보다는 여름에 많이 발생(發生), 입원(入院)하였다. 4. 입원당시(入院當時) 의식상태(意識狀態)가 안 좋았던 환자(患者)에게서 예후불량(豫後不良)한 환자(患者)가 많이 나타났다. 5. 물리치료(物理治療)의 평균(平均) 개시시기(開始時期)는 뇌경색(腦梗塞)에서 11.4일(日), 뇌출혈(腦出血)에서 22.7일(日)이었다. 6. 한(韓), 양방(洋方) 협진(協診)을 실시(實施)한 경우가 많았으며, 그 필요성(必要性)이 많이 나타났다.진단(診斷)에서부터 치료(治療)의 전과정(全過程)을 통(通)해서 서의치료(西醫治療)와 동의치료(東醫治療)를 결합(結合)하여 종합치료(綜合治療)를 하므로써 폐암(肺癌)의 치료효과(治療效果)를 높일 수 있는 새로운 치료법(治療法)으로 계속적인 연구(硏究)가 필요(必要)할 것으로 사료(思料)된다.較)하였다. 끝으로 본(本) 연구는 1965 年度 서울대학교 대학원(大學院) 연구비(硏究費)로 수행(遂行)한 것이며 본 연구를 시종 지도편달(指導鞭撻) 해 주신 서울대학교 농과대학 농화학과 주임교수 이춘영박사(李春寧博士)에게 감사(感謝)를 드리며 또한 본 연구의 시료를 제공하여 주신 서울대학교 농과대학 농학과 이고웅박사(李股雄博士)에 게 사의(謝意)를 표하는 동시에 본 연구의 분석에 협력하여 준 서울대학교 대학원 농화학과 김수영군(金洙榮君)에게 사의(謝意)를 표하는 바이다. 5 참조(參照)) (4) 벼를 pot에 심고 2회(回)에 걸쳐 control, Imidan, N-hydroxy methyl phthalimide, anthranilic acid 및 phthalimide의 10, 25, 50, 100 ppm 농도(濃度)의 각(各) 유제(乳劑)를 살포하고 일정기간후(一定期間後) 생육상(生育相)을 조사(調査)하였더니 Imidan 구(區)와 N-hydroxy methyl phthalimide 구(區)가 control 보다 좋은 성적(成績)을 보였다. (5) Imidan 250 ppm 유제(乳劑)를 수도엽면(水稻葉面)에 살포(撒布)하고 3 일(日), 5 일(日), 7 일(日) 및 14일후(日後)에 일정량(一定量)의 엽경(葉莖)을 채취(採取)하여 acetone으로 추출(抽出)k고 acetonitrile을 가지고 prechromatographic piriication 을 거쳐 paper chromatography에 의(依)하여 다음과

  • PDF