• Title/Summary/Keyword: high performance wire

Search Result 328, Processing Time 0.031 seconds

Prestressing Loss Management for PSC Girder Tendon Based on EM Sensing (EM센서를 활용한 PSC 텐던 긴장력 손실 관리)

  • Kim, Junkyeong;Park, Jooyoung;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.369-374
    • /
    • 2015
  • In this paper, an EM sensing based prestressing force estimation method is proposed, in which it can estimate tensile force of PS tendon for PSC girder. The PSC girder has more improved performance than the general concrete girder by introducing the prestressing to the concrete. Thus the PSC girder bridge is widely constructed due to its high performance and low cost. However, the prestressing force has not been managed nevertheless it is major factor for the maintenance of the PSC girder bridge. The prestressing force was just measured during construction using jacking device and after that, it can not be managed. For this reason, this paper proposes a tensile force estimation method of PS tendon based on EM sensor. The permeability of ferroelectric material is changed according to the induced stress to the material, in which it can be measured using EM sensor. To measure the permeability of PS tendon, the EM sensor was fabricated and verified by performing the MTS test. The test was performed using 7-wire steel tendon under the 0, 40, 80, 120, 160, 200 KN of tensile force. The permeability of PS tendon was gradually decreased according to the increasement of tensile force. The regression method was used to find the relation between permeability and stress. As a result, the permeability has linear relation with the tensile force of PS tendon and the pre-stressing force can be estimated by the derived estimation equation.

Development of a Systemized Flying Net for Safety Improvement in Architectural Building Construction (건설 공사의 안전성 향상을 위한 충돌방지형 시스템 플라잉넷의 개발)

  • Lee, Jeong-Ho;Park, Seon-Joo;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.5
    • /
    • pp.71-80
    • /
    • 2011
  • Flying net should be installed on every 3 or 4 construction floor from 8m above ground according to the rule. In the apartment housing construction, flying net installation work has been recognized the most dangerous work among the whole works because a small mistake of labors might make their death accident. Sub-contractors specialized in flying net have been developing various flying net types. However, most works of installing flying net as working with the developed system are performed outside the apartment housing, so that the risk of fall in works of installing supports and unfolding net is still high. Furthermore, as using the previously developed flying net labors might bump into the frame or the wire rope for supporting so that it makes secondary accidents. The objective of this research is to produce the proto-type of anti-collision flying net system based on the result of problem analysis on the installation and detachment process and suggest the improved anti-collision flying net system, which is able to improve safety and field applicability by conducting field experiment and analyzing performance.

Long-term performance of drainage system for leakage treatment of tunnel operating in cold region (한랭지역에서 운영 중인 터널의 누수처리를 위한 유도배수시스템의 장기 성능 평가)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1177-1192
    • /
    • 2018
  • The objective of this study is to develop the existing drainage system for catching the partial leakage of tunnel structures operating in cold region. The drainage system consists of drainage board, Hotty-gel as a waterproofing material, cover for preventing protrusion of Hotty-gel, air nailer, fixed nail, pipe for collecting ground leak, pipe for conveying ground leak, wire-mesh, and sprayed cement mortar. The drainage systems were installed in conventional concrete lining tunnels to evaluate the site applicability and constructability. The performances of waterproof and the drainage in the drainage system were evaluated by injecting 1,000 ml of red water in the back of the drainage system at 7 days, 14 days, 21 days, 28 days, 2 months, 3 months, 4 months, 5 months, 6 months, 7 months and 8 months. During 8 months of field test, the average daily temperature of the tunnel site was measured from $-16.0^{\circ}C$ to $25.6^{\circ}C$. The daily minimum temperature was $-21.3^{\circ}C$ and the daily maximum temperature was $30.8^{\circ}C$. There was no problem in waterproof and drainage performance of the drainage board in the drainage system. However, the pipe for conveying ground leak had the leakage problem from 14 days. It is considered that the leakage of the pipe for conveying ground leak was caused by the deformation of the pipe of the flexible plastic material having a thickness of 0.2 cm by using the high pressure air nailer and the fixing pin and the insufficient thickness and width of the hotty-gel for preventing the leakage.

Full-scale Shaking Table Test of Uninterruptible Power Supply Installed in 2-stories Steel Structure (2층 철골 구조물에 설치된 무정전전원장치의 실규모 진동대 실험연구)

  • Lee, Ji-Eon;Park, Won-Il;Choi, Kyoung-Kyu;Oh, Sang-Hoon;Park, Hoon-Yang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.29-38
    • /
    • 2022
  • In this study, the shaking table tests were carried out on six types of non-structural elements installed on a full-scale two-story steel structure. The shaking table tests were performed for non-structural elements with and without seismic isolators. In this study, the seismic performance of Uninterruptible Power Supply (UPS) specimens was tested and investigated. Non-seismic details were composed of conventional channel section steel beams, and the seismic isolators were composed of high damping rubber bearing (HDRB) and wire isolator. The input acceleration time histories were artificially generated to satisfy the requirements proposed by the ICC-ES AC156 code. Based on the test results, the damage and dynamic characteristics of the UPS with the seismic isolator were investigated in terms of the natural frequency, damping ratio, acceleration time history responses, dynamic amplification factors, and relative displacements. The results from the shaking table showed that the dynamic characteristics of the UPS including the acceleration response were significantly improved when using the seismic isolator.

Growth, Bone Mineralization and Mineral Excretion in Broiler Starter Chicks Fed Varied Concentrations of Cholecalciferol

  • Rama Rao, S.V.;Raju, M.V.L.N.;Shyam Sunder, G.;Panda, A.K.;Pavani, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.2
    • /
    • pp.237-244
    • /
    • 2007
  • An experiment was conducted to study the growth performance, bone mineralization and mineral excretion in broiler starter chicks fed high levels of cholecalciferol (CC) at sub-optimal levels of calcium (Ca) and non-phytate phosphorus (NPP). Five hundred and sixty day-old Vencobb female broiler chicks were housed in raised wire floor stainless steel battery brooder pens ($24"{\times}30"{\times}18"$) at the rate of five chicks per pen. A maize-soyabean meal basal diet was supplemented with dicalcium phosphate, oyster shell powder and synthetic CC to arrive at two levels each of Ca (0.50 and 0.60%), and NPP (0.25 and 0.30%) and four levels of CC (200, 1,200, 2,400 and 3,600 ICU/kg) in a $2{\times}3{\times}4$ factorial design. Each diet was fed ad libitum to chicks in 7 pens from 2 to 21days of age. Body weight gain, feed intake and bone weight increased (p<0.05) with increase in level of CC at both the Ca and NPP levels tested. The CC levels required to obtain significant improvement in body weight gain and feed intake reduced (2,400 ICU/kg vs. 1,200 ICU/kg) with increase in levels of P in diet (0.25% vs. 0.3%, respectively). The feed conversion ratio was significantly improved (p<0.05) with increase in level of CC from 200 to 1,200 ICU/kg diet at 0.5% Ca, while at 0.6% Ca, the level of CC in diet did not influence the feed efficiency. Tibia mineralization (density, breaking strength and ash content) and Ca and P contents in serum increased significantly (p<0.05) with increase in levels of CC in diet. The CC effect on these parameters was more pronounced at lower levels of Ca and NPP (0.5 and 0.25%, respectively). The data on body weight gain and feed intake indicated that NPP level in diet can be reduced from 0.30 to 0.25% by increasing CC from 200 to 2,400 ICU/kg. Similarly, the bone mineralization (tibia weight, density and ash content) increased non-linearly (p<0.01) with increase in CC levels in diet. Concentrations of P and Mn in excreta decreased (p<0.01), by increasing CC level from 200 to 2,400 ICU/kg diet. It can be concluded that dietary levels of Ca and NPP could be reduced to 0.50 and 0.25%, respectively by enhancing the levels of cholecalciferol from 200 to 2,400 ICU/kg with out affecting body weight gain, feed efficiency and bone mineralization. Additionally, phosphorus and manganese excretion decreased with increase in levels of CC in broiler diet.

Manufacturing and Filtration Performance of Microfiltration Metal Membrane Using Rolling Process (압연공정을 이용한 금속 정밀여과막의 제조 및 여과특성)

  • Kim, Jong-Oh;Min, Seok-Hong;Jung, Jong-Tae
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.174-183
    • /
    • 2007
  • The manufacturing process of metal membrane made of only metal mesh and both metal mesh and powder with using rolling process have been studied. In the rolling of metal mesh, selected metal meshes were rolled with the reduction ratio of 10%, 20%, and 30%, respectively. Such rolling process resulted in the decrease of mesh pore size through reduction the cross sectional area of mesh and changing the diameter of mesh wires. Also, it enhanced the filtration ratio of rolled mesh which is almost same as the filtration ratio of upper grade unrolled mesh and the reliability of membrane by making pore size distribution become more uniform. In fabricating metal powder layer onto metal mesh, using PVA(polyvinyl alcohol) as a binder of powder, drying the metal powder layer at $100^{\circ}C$ for 1 hr, and sintering it at $1,000^{\circ}C$ for 3 hr in vacuum were to be optimum conditions for obtaining good quality of metal powder layer on metal mesh with high pore density but no crack. With additional rolling of metal powder layer on metal mesh with 30% reduction before sintering, metal membrane which filtration ratio is about $0.7{\mu}m$ has been successfully manufactured.

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

Effect of adaptive movement on durability and working time of twisted file (Adaptive movement가 twisted file의 내구성과 작업 시간에 미치는 영향)

  • Lee, Sang-Ho;Park, So-Ra;Cho, Kyung-Mo;Park, Se-Hee;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.20-26
    • /
    • 2019
  • Purpose: Recently TF-adaptive movement is developed in order to increase the durability of TF files. The purpose of this study was to assess the effects of adaptive movement on durability and performance of twisted files. Materials and Methods: Resin blocks simulating artificial J-shape canals were used for this study. In TFC group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under continuous rotation 500 rpm/4.0 Ncm. In TFA group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under adaptive movement. After preparing each artificial canal, TF files were observed under dental microscope for assessing existence of unwinding, distortion, and fracture. If unwinding of flute was observed, the number of artificial canals until unwinding of flute occurs was recorded. Required time until instruments reach working length and distance of unwinded portion of files from D0 were measured. All test results were conducted by Mann-Whitney U test at a 0.05 level of significance. Results: No Ni-Ti instrument's separation was observed. Number of resin blocks until file unwinding happens and working time was significantly high in TFA group compared to TF group. Distance of distortion from D0 didn't show significant difference between TFA, TF groups. Conclusion: The number of resin blocks prepared until unwinding happens and working time were significantly high in TFA group. The location of unwinding showed no significant difference between 2 groups. Adaptive movement increased the number of canals prepared until unwinding occurs and working time of twisted files.