• 제목/요약/키워드: high organic wastewater

검색결과 441건 처리시간 0.025초

UASB 공정에 의한 슬러리형 돈사폐수의 처리 (The Treatment of Slurry-type Swine Waste using UASB Reactor)

  • 원철희;김병욱;한동준;임재명
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.583-588
    • /
    • 2004
  • This research examined the treatment efficiency and methane production rate in treating slurry-type swine waste using UASB (upflow anaerobic sludge blanket) reactor. The UASB reactor was operated at an organics volumetric loading rate (VLR) of $2.6-15.7kgCOD/m^3/day$. A stepwise increase of the VLR resulted in a temporary deterioration in the COD removal rate in UASB reactor but recovered quickly. The COD removal rate were 65-70% for VLR up to $5 kgCOD/m^3/day$. When organics VLR was $10kgCOD/m^3/day$, the COD removal rate decreased sharply and there was loss of 17.537g of the seeding biomass due to sludge washout. This result indicated that the UASB system cannot be adapted to more than $10kgCOD/m^3/day$ of VLR. As the organic load increased from 2.6 to $15.7kgCOD/m^3/d$, the biogas production rate varied from 3.2 to 10.8 L/d and the methane conversion rate of the organic matter varied from 0.30 to $0.23m^3CH_4/kg\;COD_{removed}$. The methane content showed the range of 70.1-81.5% during the experimental period. The volatile solids (VS) removal efficiency was similar at the low VLR (< $5 kgCOD/m^3/day$), but it decreased sharply at the high VLR (> $5 kgCOD/m^3/day$). The VS reduction rate was, moreover, large those of COD. The result shows that hydraulic retention time above 2 days is essential in case of treating wastewater containing 1% of solids.

접촉담화공정에 의한 폐수처이에 있어서의 제한요권에 관한 연구 (A Study on the Limiting Factors in Wastewater Treatment by Contact Oxidation Process)

  • 황상용;손종열;우완기
    • 환경위생공학
    • /
    • 제5권2호
    • /
    • pp.45-52
    • /
    • 1990
  • This study is to discuss limiting factors influenced on the removal efficiency of organic materials investigated using the polypropyrene biofilter which appropriate to attach micro-organism in order to apply the contact oxidation proce,:5. The results obtained in the experiment were as follows : 1. In the range o: pH 4.0~ 12.0 was obtained the removal efficiency of COD higher than 85% It was proved that variation of pH(4.0 ~ 12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 2. Temperature to obtain removal efficiency of COD higher than 85% was $10^{\circ}$ ~$40^{\circ}$. Removal efficiency of COD was no less than those at high temperature if MLVSS concentration was maintained 8,000~ 15,000 m/1. 3. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/.d below. And then the HRT was Bhrs. 4. In comparison with the conventional activate sludge process, the contact oxidation process was excellent in removal efficiency, sludge production rate and maintenance.

  • PDF

혐기성 유동층 반응기에서 페놀 폐수 처리에 관한 연구 (A Study on the Treatment of Phenol Wastewater in an Anaerobic Fluidized-Bed Reactor)

  • 박동일;안재동;신승훈;장인용
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.96-103
    • /
    • 1996
  • The objectives of this study were to examine the biodegradation of phenol using the anaerobic fluidized bed reactor(AFBR). Mixed microorganisms were selected from the anaerobic digestion tank, and could be adapted to high concentration of phenol by increasing the phenol concentration 600-3600 mg/l step by step. The results were summarized as follows: 1. The average removal efficiency of phenol was 90%, decreased by increasing concentration of phenol, and then a shock range was 1200~2400 ppm. 2. The production rate of biogas in overall limits was proportional to the concentration of influent phenol. 3. At steady state, compositions of gases were $CH_4$ 55~60%, $C0_2$ 34~43%, respectively. These were similar to that of the theoretical estimates. 4. The production rates of biogas and methane per the molarity of phenol removed were linearly increased, 56.45 l gas/mol-phenol and 29.20 l $CH_4/mol$-phenol. Using this biogas, the recoverable energy was 269.1 kcal/mol phenol. It was 120.2 kcal/g-COD, transforming into the chemical oxygen demand. 5. The bulk of microorganisms existed in suspended section of fluidized bed with type of biofilm and its concentration was 340 mg/g-media. In conclusion, the anaerobic treatment of pure phenol was possible and its removal efficiency, introducing the AFBR, was successful. Also toxic organic compound such as phenol was biodegradable and was recoverable as resource of energy.

  • PDF

메리골드 안료를 이용한 친환경 텍스타일 프린팅(1): 바인더의 종류와 혼합비율의 효과 (Eco-friendly Textile Printing using Marigold Pigment(1): Effect of Binder Type and Mixing Ratio)

  • 여영미;신윤숙
    • 한국염색가공학회지
    • /
    • 제31권4호
    • /
    • pp.233-240
    • /
    • 2019
  • Dyeing is an essential process for improving the value of textile products, but it is considered as one of industries causing pollution because of producing wastewater containing hazardous chemicals as well as using a large amount of water and energy. Global demand for greener technologies in textile field is getting much more attention and accordingly, the use of eco-friendly natural dyes is growing much larger. In textile printing, both dyes and pigments can be used. Pigment printing is more simple process and requires less water and less energy, compared to dye printing. In this study, the organic pigment was prepared from the marigold colorant. Samples were stencil printed, pressed(70℃, 3min) and then heat treated(150℃, 5min). The uptake of polyacrylic acid as a chemical binder was the lowest. In particular, marigold pigments were excellent in color and texture when Guar Gum and Sodium Alginate were used as binders. In addition, the light and washing fastness was rated very high as 4, 4/5 grades, and the rubbing fastness was also excellent as 3 and 4 grades.

용수 재이용을 위한 소규모 하수처리시설의 UV disinfection system (Feasibility Study of UV Disinfection system of Small Wastewater System for Water Reclamation)

  • 정광욱;윤춘경;함종화
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.421-424
    • /
    • 2002
  • Deterministic and probabilistic approaches to the design of ultraviolet (UV) disinfection system for water reclamation are reviewed and discussed. The high inactivation of TC, FC and E. coli by UV disinfection was demonstrated and the inactivations of TC, FC and E. coli were 97%, 98% and 99%, respectively. Within the range of 0.3-4.5mWs/cm, the effect of UV does on the inactivation ratio was not observed. However, in the highest wattage of UV lamp, 39W, the inactivation ratio of TC, FC and E. coli was 100%, regardless of the UV does so the UV density was more effective on inactivation ratio of TC, FC and E. coli rather than UV does. Under the 0.4 mWs/cm and 16W of UV lamp, the effect of dissolved organic matter and turbidity on the inactivations of TC, FC and E. coli could not be observed in this study within the range of 0-60mg/L and 0-40 NTU respectively.

  • PDF

Degradation of oxytetracycline by nano zero valent iron under UV-A irradiation: Chemical mechanism and kinetic

  • Hassanzadeh, Parisa;Ganjidoust, Hossein;Ayati, Bita
    • Advances in environmental research
    • /
    • 제3권1호
    • /
    • pp.29-43
    • /
    • 2014
  • Pharmaceutical wastewater effluents are well known for their difficult elimination by traditional biotreatment methods and their important contribution to environmental pollution due to its fluctuating and recalcitrant nature. OTC is one of the nonbiodegradable antibiotics that makes antibiotic-resistant, so it can make be high risk for environment. NZVI can be a good choice for removal of OTC in aqueous solution. Response surface methodology (RSM) was used to optimize the amounts of NZVI and OTC to be used at pH 3 and under 200 W, UV-A irradiation. The responses were removal percent of absorption at 290 and 348 nm, TOC and COD of OTC. In the optimum condition, Linear model was performed 155 ppm of OTC were removed by 1000 ppm NZVI after 6.5 hours and the removal efficiency of absorption at 290 and 348 nm, TOC and COD were 87, 95, 85 and 89 percent, respectively. In the similar process, there is no organic compound after 14 hours. The parameters ORP, DO and pH were investigated for 6:30 hours to study the type of NZVI reaction in process. In the beginning of reaction, oxidation was the dominant reaction after 3 hours, photocatalytic reaction was remarkable. The mechanism of OTC degradation is proposed by HPLC/ESI-MS and four by products were found. Also the rate constants (first order kinetic chain reaction model) were 0.0099, 0.0021, 0.0010, 0.0049 and $0.0074min^{-1}$, respectively.

유전체 장벽 방전 플라즈마 반응기를 이용한 페놀 처리 (Phenol Treatment Plasma Reactor of Dielectric Barrier Discharge)

  • 박영식
    • 한국환경과학회지
    • /
    • 제21권4호
    • /
    • pp.479-488
    • /
    • 2012
  • A Dielectric barrier discharge (DBD) plasma is shown in the present investigation to be effective of phenol degradation in the aqueous solutions in batch reactor with continuous air bubbling. Removal of phenol and effects of various parameters on the removal efficiency in the aqueous solution with high-voltage streamer discharge plasma are studied. The effect of 1st voltage (80 ~ 220 V), air flow rate (3 ~ 7 L/min), pH (3 ~ 11), electric conductivity of solution (4.16 ${\mu}S$/cm, deionized water) ~ 16.57 mS/cm (addition of NaCl 10 g/L) and initial phenol concentration (2.5 ~ 20.0 mg/L) were investigated. The observed results showed that phenol degradation was higher in the basic solution than that of the acidic. The optimum values on the 1st voltage and air flow rate for phenol degradation were 140 V and 6 L/min, respectively. It was considered that absorbance variation of $UV_{254}$ of phenol solution can be use as an indirect indicator of change of the non-biodegradable organic compounds within the treated phenol solution. Electric conductivity was not influenced the phenol degradation. To obtain the removal efficiency of phenol and COD of phenol over 97 % (initial phenol concentration, 10.0 mg/L), 80 min and 120 min were need, respectively. Phenol and COD degradation showed a pseudo-first order kinetics.

SPAD(Sulfur Particle Autotrophic Denitrification) 공법의 고농도 질산성 질소 함유 페수에 대한 파일럿 스케일 적용사례

  • 박우신;김성연;범민수;김인수
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.68-71
    • /
    • 2002
  • SPAD공법은 탈질을 위한 전자공여체로 입자상의 황과 소량의 메탄올을 이용하는 생물학적 공법이다. 이번 연구에서 SPAD공법은 특정 폐수에의 적용가능성을 평가하기 위해 고농도의 칼슘이온을 함유한 울산의 S특수강 폐수(200-300$NO_3\;^-$ -N/L)에 적용되었다. 운전기간은 2001년 11월부터 2002년 3월 초까지였으며 반응조 내부의 온도는 약 $20^{\circ}C$ 부근으로 유지되었고, 그러한 낮은 온도조건하에서도 탈질 효율은 90%이상으로 유지되었으며 유출수 농도는 약 20mg $NO_3\;^-$ -N/L정도로 유지되었다. 따라서 SPAD공법은 고농도의 칼슘이온을 함유한 폐수에 대해 적용이 가능한 것으로 사료되어진다.

  • PDF

Pseudomonas sp. BCNU 106의 persolvent fermentation에 의한 인디고이드계 색소 생산 (Production of Indigoid Pigments by Persolvent Fermentation with Pseudomonas putida BCNU 106)

  • 최혜정;권기석;주우홍
    • 생명과학회지
    • /
    • 제24권1호
    • /
    • pp.81-85
    • /
    • 2014
  • 산업폐수로부터 분리한 Pseudomonas sp. BCNU 106은 다양한 유기용매를 이용하여 인돌로부터 인디고를 합성할 수 있다. BCNU 106은 높은 수준의 인돌과 다량의 p-xylene, propylbenzene 그리고 mesitylene의 존재 하에서 효과적으로 인디고를 생산했다. 본 연구에서 인디고의 최대수율 조건은 20% (v/w)의 p-xylene과 4 g/l의 인돌인 것으로 확인되었다. 이러한 조건에서 인디고의 수율과 인돌의 전환효율은 각각 315.5 mg/l와 97%로 조사되었다. 그 결과 Pseudomonas sp. BCNU 106은 산업적으로 중요한 인디고 생산을 위한 잠재적인 균주가 될 것으로 판단된다.

산소-플라즈마 방전을 이용한 수중의 페놀 제거 (Phenol Removal Using Oxygen-Plasma Discharge in the Water)

  • 박영식
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.915-923
    • /
    • 2013
  • Decomposition of non-biodegradable contaminants such as phenol contained in water was investigated using a dielectric barrier discharge (DBD) plasma reactor in the aqueous solutions with continuous oxygen bubbling. Effects of various parameters on the removal of phenol in aqueous solution with high-voltage streamer discharge plasma are studied. In order to choose plasma gas, gas of three types (argon, air, oxygen) were investigated. After the selection of gas, effects of 1st voltage (80 ~ 220 V), oxygen flow rate (2 ~ 7 L/min), pH (3 ~ 11), and initial phenol concentration (12.5 ~ 100.0 mg/L) on phenol degradation and change of $UV_{254}$ absorbance were investigated. Absorbance of $UV_{254}$ can be used as an indirect indicator of phenol degradation and the generation and disappearance of the non-biodegradable organic compounds. Removal of phenol and COD were found to follow pseudo first-order kinetics. The removal rate constants for phenol and COD of phenol were $5.204{\times}10^{-1}min^{-1}$ and $3.26{\times}10^{-2}min^{-1}$, respectively.