Abstract

SPAD(Sulfur Particle Autotrophic Denitrification) process is a biological denitrification process which uses elemental sulfur as an electron donor and a mall amount of organic to assist autotrophic denitrification. $^{1)}$SPAD process was applied to a nitrate containing wastewater (200-300mg $NO_3\;^-$ -N/L) with high concentration of $Ca^{2+}$ ion(5000-15000mg/L) from S. Steel Co. in Ulsan city, to est the feasibility of SPAD process. This pilot was operated from November 2001 to early March 2002, and the inner temperature of the pilot was controlled around $20^{\circ}C$. In spite of low temperature, denitrification efficiency was maintained above 90% achieving the average effluent $NO_3\;^-N$ concentration around 20mg$NO_3\;^-$ -N/L.

SPAD공법은 탈질을 위한 전자공여체로 입자상의 황과 소량의 메탄올을 이용하는 생물학적 공법이다. 이번 연구에서 SPAD공법은 특정 폐수에의 적용가능성을 평가하기 위해 고농도의 칼슘이온을 함유한 울산의 S특수강 폐수(200-300$NO_3\;^-$ -N/L)에 적용되었다. 운전기간은 2001년 11월부터 2002년 3월 초까지였으며 반응조 내부의 온도는 약 $20^{\circ}C$ 부근으로 유지되었고, 그러한 낮은 온도조건하에서도 탈질 효율은 90%이상으로 유지되었으며 유출수 농도는 약 20mg $NO_3\;^-$ -N/L정도로 유지되었다. 따라서 SPAD공법은 고농도의 칼슘이온을 함유한 폐수에 대해 적용이 가능한 것으로 사료되어진다.