• 제목/요약/키워드: high gradient magnetic separation

검색결과 54건 처리시간 0.025초

Recent development of high gradient superconducting magnetic separator for kaolin in china

  • Zhu, Zian;Wang, Meifen;Ning, Feipeng;Yang, Huan;Li, Peiyong;Zhang, Yiting;Wang, Zhaolian;Zhang, Guoqing;Hou, Zhilong;Liu, Zhongxiu;Dai, Zhong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.5-8
    • /
    • 2017
  • A series of high gradient superconducting magnetic separator (HGMS) for kaolin has been developed. It is used for processing kaolin to increase the brightness or whiteness whether it is for paper or ceramic applications. The HGMS system mainly consists of a solenoid magnet with a zero boil-off helium cryostat, a double reciprocating canisters system, and a PLC (Process Logic Controller) fully automatic control system based on SCADA (Supervisory Control and Data Acquisition) system. We have successfully developed CGC-5.5/300 and CGC-5.0/500 HGMS systems in the recent years, and now three sets of them are on-site operation in different customers. This paper will present recent progress of the HGMS system, the results of some experiments on processing kaolin clay used HGMS, and the on-site operation.

Magnetic-activated cell sorting improves high-quality spermatozoa in bovine semen

  • de Assumpcao, Teresinha Ines;Severo, Neimar Correa;Zandonaide, Joao Pedro Brandao;Macedo, Gustavo Guerino
    • 한국동물생명공학회지
    • /
    • 제36권2호
    • /
    • pp.91-98
    • /
    • 2021
  • The objective of this study was to establish a selection process for high quality sperm in bovine semen using sperm separation by magnetic activation (MACS). For this, semen from 21 Nellore bulls was collected using an artificial vagina. To guarantee the presence of pathologies in the ejaculate, animals previously declassified in four consecutive spermiogram were used. Semen was analyzed in five statuses: (1) fresh semen (fresh); (2) density gradient centrifugation (DGC), percoll column; (3) non-apoptotic fraction after separation by MACS (MAC); (4) apoptotic fraction from the separation (MACPOOR); and (5) MAC followed by DGC (MACDGC). Using a computerized analysis system (CASA), motility was measured. The sperm morphology was evaluated by phase contrast, and the supravital test was completed with eosin/nigrosin staining. For DGC, 20 × 106 cells were used in a gradient of 90% and 45% percoll. MACS used 10 × 106 cells with 20 μL of nanoparticles attached to annexin V, and filtered through the MiniMACS magnetic separation column. Membrane integrity was assessed with SYBR-14/IP and mitochondrial potential with JC-1 by flow cytometry. Processing sperm by MACDGC, was more effective in obtaining samples with high quality sperm, verified by the total of abnormalities in the samples: 35.04 ± 2.29%, 21.50 ± 1.47%, 17.30 ± 1.10%, 30.68 ± 1.94% and 10.50 ± 1.46%, respectively for fresh, DGC, MAC, MACPOOR, and MACDGC. The subpopulation of non-apoptotic sperm had a high number of live cells (82.65%), membrane integrity (56.60%) and mitochondrial potential (83.98%) (p < 0.05). These findings suggest that this nanotechnological method, that uses nanoparticles, is efficient in the production of high-quality semen samples for assisted reproduction procedures in cattle.

An Open Gradient Magnetic Separator Assembled Using NdFeB Magnets for a Use of Fine Particles Remover

  • Park, Eon-Byung;Choi, Seung-Duck;Yang, Choong-Jin;Lee, Won-Sub
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.69-73
    • /
    • 1998
  • A drum type magnetic separator was designed and optimized by computer simulation. The separator consisted of rotating outer shell of drum, magnetic flux generator drum which was assembled with numbers of disk type magnet holders, and drum axis around which the magnet holders were fixed. NdFeB magnet blocks were inserted into the disks, and the disks were assembled layer by layer along the drum axis. Magnetic circuits of the separator were simulated on the basis of highest magnetic strength, least cost, and high yield of separation by using a Vector Field S/W employing the Opera-2D program. The separator proved a separation yield of 95% in removing fine iron-base particles, and installed at Hot Rolling Mill of Pohang Iron & Steel Co. In Korea.

  • PDF

The review of international forum on magnetic force control IFMFC activity from 2010

  • Watanabe, Tsuneo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-6
    • /
    • 2022
  • The Magnetic Force Control MFC technology is very useful because of its physical treatment process. Especially the Magnetic Separation MS technology is expected to contribute to SDGs 2030, Circular Economy and Carbon neutral 2050 realization. This paper describes the review of the IFMFC activity from 2010.The IFMFC is organized by three local committees of researchers in Japan, China and Korea. The IFMFC aims to exchange the information of the development results using the MFC technology and to educate the young researchers. The forum has been held in every year around three countries. In 2020 and 2021, the forum was organized by Zoom online due to the COVID-19. The 134 presentations were made up to 2020.The breakdown of these presentations are categorized to the environment remediation52%, material resource37% and fundamental research/technology11%. The Super Conducting Magnet SCM development promotes the MFC technologies. There are some impressive backgrounds as to the brilliant SM technology applications for many different magnetism ; SCM development, High Gradient Magnetic Separation HGMS, magnetic seeding method and magneto-Archimedes effect. This paper reviews the IFMFC activity according to those presented presentations.

물질분리를 위한 전도냉각형 초전도자석 시스템 개발 (Development of a Conduction-Cooled Superconducting Magnet System for Material Separation)

  • 최연석;김동락;이병섭;양형석;정원묵
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.50-54
    • /
    • 2008
  • A conduction-cooled superconducting magnet system is developed for material separation. The superconducting magnet for material separation has to be designed to have a strong magnetic field in a control volume. Since the magnetic field gradient is larger at the end rather than at the center of the magnet, we developed a design method to optimize the superconducting magnet for material separation. The safety of the superconducting magnet is evaluated, taking into account the electro-magnetic field, heat and structure. The superconducting coil is successfully wound by the wet-winding method. The superconducting coil is installed in a cryostat maintaining high vacuum, and cooled down to approximately 4 K by a two-stage GM cryocooler. The performance of the conduction-cooled superconducting magnet system is discussed with respect to the supplied current, cooling medium and cooling power of a cryocooler.

  • PDF

제철 폐수의 고구배 자기분리HGMS(High Gradient Magnetic Seperation) 처리에 관한 연구 (Study on the Purification of Wastewater by Superconducting HGMS for Steelmaking Industry)

  • 김태형;하동우;오상수;하태욱;김영훈;강채훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.360-360
    • /
    • 2008
  • Steelmaking industry is widely known to use a lot of water and same amount of wastewater is generated. Although toxicity of wastewater from Steelmaking industry is low, it contains an amount of various organic materials and Fe-Oxides. It is important to recycle the wastewater because of water shortages and water pollution. In general, large-scale equipment is necessary to process the wastewater. On the other hand, superconducting high gradient magnetic separation (HGMS) system can process the wastewater in the small space. Superconducting HGMS system that had a purpose to purify the wastewater was assembled. Cryo-cooled Nb-Ti superconducting magnet was used for magnetic separator. This system can operate continuously because contaminated filters can keep on returning after cleaning. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. Filter cleaning system was developed to decrease the quantity of clean water. This research was supported by a grant from Korea Electrotechnology Research Institute, Republic of Korea.

  • PDF

Application of Superconducting Magnetic Separation for Condenser Water Treatment in Thermal Power Plant

  • Lee, You-Jin;Kwon, Jun-Mo;Baik, Seung-Kyu;Han, Kwang-Soo;Ko, Rock-Kil;Sohn, Myung-Hwan;Ha, Dong-Woo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권2호
    • /
    • pp.21-24
    • /
    • 2011
  • Superconducting high gradient magnetic separation (HGMS) has advantages to treat wastewater because it can generate high magnetic field and achieve rapid purification. In this study superconducting HGMS was applied to remove impurities from the condenser water in thermal power plant. The condenser water contained mainly hematite and maghemite and it was highly magnetized than hematite. In the HGMS tests using a 6-T cryo-cooled Nb-Ti superconducting magnet, the turbidity of the condenser water was effectively reduced up to 99.6% and the result showed better performance than that of the 0.5-T permanent magnet test. The higher magnetic field was applied in the range of 1-6T, the more iron oxides were removed. The effect of magnetic filter configuration on the condenser water treatment was also investigated. Consequently superconducting HGMS system can be applicable to remove iron oxide impurities from condenser water in thermal power plant.

전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수 (Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator)

  • 하동우;김태형;손명환;권준모;백승규;오상수;고락길;하홍수;김호섭;김영훈;강채훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF