• Title/Summary/Keyword: high flowable

Search Result 73, Processing Time 0.022 seconds

Properties of Flowable High-volume Fly Ash-Cement Composites (다량의 플라이애쉬를 사용한 유동성 시멘트복합체의 특성)

  • 원종필;신유길;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.105-110
    • /
    • 1998
  • The purpose of this was to examine the used of fly ash as a type of construction material. In this paper the results from a recent study on development of a cement composite utilizing relatively large amount of fly ash are presented. The flowable fly ash-cement sand composite was investigated for strength and flowability characteristics. The independent variable considered were: fly-ash content, sand content, and ratio of water to cementitious materials. Results of this study show that high volume fly-ash composite can be proportioned to obtain 10~15kg/$\textrm{cm}^2$ compressive strength at 28 days. For applications requiring strength between 10kg/$\textrm{cm}^2$ and 15kg/$\textrm{cm}^2$, the mixture with fly ash-cement ratio of 5.6 and sand-cement ratio of 28 with relatively high water content may be used. Slump was held at 25$\pm$1cm for all mixtures produced compressive strength at 28 days were found to range from 5kg/$\textrm{cm}^2$ to 13.7kg/$\textrm{cm}^2$.

  • PDF

An experimental study on mix design for flowable fill with high volume fly ash content (다량의 플라이애쉬를 사용한 고유동충진재의 배합설계를 위한 실험적 연구)

  • 원종필;신유길
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.130-135
    • /
    • 1998
  • This paper presents results of research performed to identify optimum mix proportions for production of flowable fill with high volume fly ash content. The fly ash used in this study met the requirements of KS L 5405 and ASTM C 618 for Class F material. Tests were carried out on concrete designed to have 10 ~ 15kg/$\textrm{cm}^2$ compressive strength at the 28-day age with fly ash contents of approximately 280kg/㎥. Slump was held at 25$\pm$1cm for all mixtures produced compressive strengths at 28 days were found to range from 5.03 to 13.69kg/$\textrm{cm}^2$.

  • PDF

EFFECT OF C-FACTOR AND LAYERING TECHNIQUE ON THE CONTRACTION FORCE OF COMPOSITE RESIN RESTORATION TO TOOTH SURFACE (C-factor와 충전법이 복합레진의 중합 수축에 의한 치질에서의 수축 응력에 미치는 영향)

  • Lee, Bong-Kyu;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.233-243
    • /
    • 2006
  • The aim of this study was to investigate the relationship between the C-factor and shrinkage strain values of composite resin and examine the strain values in different incremental filling techniques. Experiment consisted two aims. First, we compared with strain value in two different C-factors(3.7 and 1.0). Second, we examined the strain values in three different filling techniques. The results of the present study can be summarized as follows : 1. High C-factor groups showed higher contraction stress values than low C-factor groups at 900 sec after polymerization. 2. Hybrid resin showed higher contraction stress values than flowable resin in high C-factor cavities. But contraction stress was not revealed significant difference between hybrid resin and flowable resin in low C-factor cavities (P>0.05). 3. Bulk felling with hybrid resin(Group 1) showed high contraction stress and lining with flowable resin followed hybrid resin (Group 5) showed lower contraction stress. 4. Contraction stress were increased during 900 sec after polymerization in high C-factor groups but decreased gradually after 900 sec. 5. Low C-factor groups showed tight marginal seal between resin and cavity wall but high C-factor groups showed gaps formed between resin and cavity wall in part. On the basis above results, layering techniques in high C-factor cavity showed advantages in reducing contraction stress and gap formation between cavity wall and resin restoration.

  • PDF

Acid Neutralizing Capacity of Giomer in an Acidic Solution (자이오머의 산성용액에 대한 산중화능)

  • Ahn, Ha-Na;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.168-176
    • /
    • 2013
  • The aim of this study was to evaluate the acid neutralizing capacity and to observe surface changes of giomer in comparison with composite resin, when it comes in contact with an acidic solution. A packable giomer(Beautifil II) and a flowable giomer(Beautifil Flow F02) were used as experimental groups, while a packable composite resin($Filtek^{TM}$ Z-250) was used as control group. pH values were measured after mixing the specimens of the disc and powder types with a pH 2.0 hydrochloric acid solution, respectively. Also, in the case of powder type giomers used in the earlier experiment, their pH values were measured again after mixing them with a fresh acid solution. Moreover, surface structure changes of disc type specimens were observed by using a scanning electron microscopy(SEM). In the disc type test, the pH values of packable giomer were significantly increased after 24 hours(p < 0.05). In contrast, in the powder type test, the pH values of packable and flowable giomers were dramatically increased within 30 minutes. The pH value of packable giomer, in particular, was higer than that of flowable giomer(p < 0.05). In the repeated neutralizing test, the degree of pH variation was lower than that of the previous neutralizing test(p < 0.05). Erosive changes on the surface of packable giomer were observed to be more than those on composite resin and flowable giomer as well. In conclusion, giomer has a acid neutralizing capacity, when it comes in contact with an acidic solution. Especially, packable giomer with high filler content has a greater acid neutralizing capacity than flowable giomer.

Study for Korean Fly Ash Characterization (국내 플라이 애쉬의 품질특성에 관한 연구)

  • 강민호;하재담;김기수;차춘수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.95-98
    • /
    • 1998
  • Fly ash is glassy dust collected from coal fired power plant. Recently, much research for fly ash conducted in Korea and fly ash is a valuable material especially when it used in high strength, high flowable, high durability concrete. But it varies with coal source, coal grinding and boiler conditions. Therefore, it is important that quality control of fly ash itself to get high quality concrete. In this study, over 20 samples of Poryong and Samchonpo fly ashs are tested and analyzed. The physical, chemical properties of fly ash and their relationships are investigated and it can be applied to quality control of concrete.

  • PDF

Development of Flowable Backfill Material Using Waste Oyster Shell, Coal Ash, and Surplus Soil (굴패각, 석탄회 및 굴착잔토를 이용한 무다짐 처리공법용 뒷채움재 개발)

  • Kim, Min-Jin;Wang, Xue;Lee, Je Joo;Lee, Sang Ho;Kim, Sung Bae;Kim, Chang-Joon
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.423-429
    • /
    • 2013
  • This study aimed to develop flowable backfill material using oyster shell, coal ash, and surplus soil. The high temperature (> $800^{\circ}C$) reaction was required to convert $CaCO_3$ to CaO. The solid specimens formed by pozzlanic reaction between CaO and coal ash showed low unconfined compressive strength. The effect of kaolin and blast furnace slag was also examined. It was found that CaO and coal ash could not be utilized due to high cost and low performance. The use of oyster shell without calcination ($CaCO_3$) was evaluated. The specimens composing of oyster shell and cement showed the higher unconfined compressive strength than that composing of coal ash and cement. However, use of oyster shell is limited in mortar due to the presence of salt. Addition of soil into oyster shell-coal ash-cement mixture satisfied the specification of flowable backfill material by optimizing their ratio.

A Study of the Characteristics of the High-flowable Concrete according to the change of charge-time of superplasticize (유동화제 첨가시기에 따른 콘크리트의 특성에 관한 실험적 연구)

  • Kwon, Chun-Ahn;Jeon, Hyun-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.115-122
    • /
    • 2003
  • In order to analyze liquidity change according to increasing the charge of superplasticizer, we inputted charges by dividing into six steps, 0% through 1.25%; at the same time, to observe liquidity change according to the change of charge-time, we carried out the experiment applying 30-minute intervals, i.e. at beginning of mixing, 30, 60 and 90 minutes. The results are below. 1) According to increasing the charge of superplasticizer, the liquidity of concrete was enhanced, however, when inputted 1.25%, a little segregation was occurred, which allowed us to make a conclusion that concrete performance would be deteriorated due to this segregation. 2) When we inputted 1.25% of superplsticizer, steady liquidity features were shown regardless of the charge-time of concrete, which allowed us to make a conclusion that this input would be the best for liquidity performance considering only liquidity features. 3) After analyzing the dynamical features of liquid concrete, the result showed that there was not significant effect on revelation of compressive strength. We concluded form this result that there was no influence on the stripping-time of a mold form. 4) When we charge superplasticizer in concrete more than 1%, we, in advance, should clearly judge the concrete performance required during constructing in site, as it were, the compressive strength or liquidity etc.; furthermore, we had better decide a charge and input-time of superplasticizer to meet the required performance.

Experimental Study on High Strength and high Flowable Concrete Filled Steel Tube for Practical Construction Application (합성강관 충전용 고강도-초유동 콘크리트의 현장적용을 위한 실험적 연구)

  • 윤영수;이승훈;성상래;백승준
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.2
    • /
    • pp.151-161
    • /
    • 1996
  • This paper presents a series of tests to produce the h~gh quality concrete to be filled Inside the steel tube columns. Thls concrete filled steel tube system requires not only the high strength, but a150 the flowable concrete. Laboratory test has been performed to clarlfy the material characteristics and to produce the optlmal mix design proportion. Full scale site mock up test has been then carried out to slnlulate the actual construct~on conditions including the product~on of concrete at the rermcon batch plant, transportation to the construction site, proper workabil~ ty and man power required , 4ddit1onal mock up test has finally been performec to irivesti gate any unfavorable construction s~tuatioils since the actual concrete placement has been sched uled in cold weather period, so that the high quality concrete construction is convinced to be successfully carried out.

Adhesive Properties of High Flowable SBR-modified Mortar for Concrete Patching Material Dependent on Surface Water Ratio of Concrete Substrate (콘크리트 피착체의 표면수율에 따른 단면복구용 고유동성 SBR 개질 모르타르의 부착특성)

  • Do, Jeong Yun;Kim, Doo Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.124-134
    • /
    • 2013
  • This study investigated the effect of surface water on concrete substrate on adhesive strength in tension of very high flowable SBR-modified cement mortar. The specimens were prepared with proportionally mixing SBR latex, ordinary portland cement, silica sand, superplasticizer and viscosity enhancing agent. Polymer cement ratio (P/C) were 10, 20, 30, 50 and 75% and the weight ratio of fine aggregate to cement were 1:1 and 1:3. The specimens obtained with different P/C and C:F were characterized by unit weight, flow test, crack resistance and adhesion test. After basic tests, two mixtures of P/C=20% and 30% in case of C:F=1:1, and one mixture of P/C=50% in case of C:F=1:3 were selected, respectively. These three selected specimens were studied about the effect of surface water evenly sprayed on concrete substrate by a amount of 0, 0.006, 0.012, 0.017, 0.024g per unit area ($cm^2$) of concrete substrate surface The results show that surface water on concrete substrate increases the adhesive strength in tension of high flowable SBR-modified cement mortar and improve the flowability compared to the non-sprayed case.

Effect of tribochemical silica coating on the shear bond strength of rebonded monocrystalline ceramic brackets (단결정형 세라믹 브라켓의 재접착 시 tribochemical silica coating이 전단접착강도에 미치는 영향)

  • Jeon, Young-Mi;Son, Woo-Sung;Kang, Sang-Wook
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.184-194
    • /
    • 2010
  • Objective: The purpose of this study was to investigate the effect of tribochemical silica coating on the shear bond strength (SBS) of rebonded ceramic brackets using nano-filled flowable composite resin. Methods: A total of 60 premolars were prepared and divided into 4 equal groups as follows: Tribochemical silica coating (TC) + Transbond XT (XT), TC + Transbond supreme LV (LV), Sandblast treatment (SA) + XT, SA + LV. Treated ceramic brackets were rebonded on the premolars using each adhesive. All samples were tested in shear mode on a universal testing machine. Results: SBS of silica coated groups were high enough for clinical usage (TCLV: 10.82 $\pm$ 1.82 MPa, TCXT: 11.50 $\pm$ 1.72 MPa). But, SBS of the sandblast treated groups had significantly lower values than the tribochemical silica coated groups (SALV, 1.23 $\pm$ 1.16 MPa; SAXT, 1.76 $\pm$ 1.39 MPa; p < 0.05). There was no difference between the shear bond strength by type of adhesive. In the silica coated groups, 77% of the samples showed bonding failure in the adhesive. In the sandblast treated group, all bonding failures occurred at the bracket-adhesive interface. Conclusions: The result of this study suggest that newly introduced nano-filled flowable composite resin and tribochemical silica coating application on debonded ceramic bracket bases can produce appropriate bond strengths for orthodontic bonding.