• Title/Summary/Keyword: high dose rate

Search Result 879, Processing Time 0.026 seconds

Assessment of occupational radiation exposure of NORM scales residues from oil and gas production

  • EL Hadji Mamadou Fall;Abderrazak Nechaf;Modou Niang;Nadia Rabia;Fatou Ndoye;Ndeye Arame Boye Faye
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1757-1762
    • /
    • 2023
  • Radiological hazards from external exposure of naturally occurring radioactive materials (NORM) scales residues, generated during the extraction process of oil and gas production in southern Algeria, are evaluated. The activity concentrations of 226Ra, 232Th, and 40K were measured using high-purity gamma-ray spectrometry (GeHP). Mean activity concentration of 226Ra, 232Th and 40K, found in scale samples are 4082 ± 41, 1060 ± 38 and 568 ± 36 Bq kg-1, respectively. Radiological hazard parameters, such as radium equivalent (Raeq), external and internal hazard indices (Hex, Hin), and gamma index (Iγ) are also evaluated. All hazard parameter values were greater than the permissible and recommended limits and the average annual effective dose value exceeded the dose constraint (0.3 mSv y-1). However, for occasionally exposed workers, the dose rate of 0.65 ± 0.02 mSv y-1 is lower than recommended limit of 1 mSv y-1 for public.

Accelerated Soft Error Rate Study with Well Structures

  • Kim, Do-Woo;Gong, Myeong-Kook;Wang, Jin-Suk
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.1
    • /
    • pp.15-18
    • /
    • 2003
  • The characteristics of accelerated soft error rate (ASER) for fabricated 8M SRAM are evaluated for various well structures. The application of the Buried NWell (BNW) and the variations of each well structure, well dose in process conditions are checked by ASER failure in time (FIT) in terms of reliability. The application of only the BNW shows the lowest ASER FIT value. The BNW added to the Buried PWell (BPW) shows a 200% increase and the BNW plus the Striped BPW (SBPW) shows a 100% increase compared to applying the BNW. The cases of applying SBPW show very high ASER FIT.

Radiation effect on the corrosion of disposal canister materials

  • Minsoo Lee;Junhyuk Jang;Jin Seop Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.941-948
    • /
    • 2024
  • The effects of radiation on the corrosion of canister materials were investigated for the reliable disposal of high-level radioactive waste. The test specimens were gamma-irradiated at a very low dose rate of approximately 0.1 Gy/h for six and twelve months. The copper and cast iron species were less corroded when irradiated. It is hypothesized that gamma rays suppress the formation of lower-enthalpy species like metal oxides and activate reductive reactions. In contrast, it was difficult to evaluate the effect of radiation on the corrosion of titanium and stainless steel.

Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy (국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료)

  • Choi Chul-Won;Kim Mi-Sook;Cho Chul-Koo;Yoo Seong-Yul;Yang Kwang-Mo;Yoo Hyung-Jun;Lee Dong-Han;Ji Young-Hoon;Han Chul-Ju;Kim Jin;Kim Young-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.11-20
    • /
    • 2006
  • Puroose: In order to find out whether stereotactic radiation therapy (RT) using CyberKnife (CK) could improve survival rate and lower acute toxicity compared to conventional RT. Materials and Methods: From April 2003 through April 2004, 19 patients with Eastern Cooperative Oncology Group (ECOG) performance status ${\leq}3$ and locally advanced pancreas cancer without distant metastasis, evaluated by CT or PET/CT, were included. We administered stereotactic RT consisting of either 33 Gy, 36 Gy or 39 Gy in 3 fractions to 6, 4 and 9 patients, respectively, in an effort to increase the radiation dose step by step, and analyzed the survival rate and gastrointestinal toxicities by the acute radiation morbidity criteria of Radiation Therapeutic Oncology Group (RTOG). Prognostic factors of age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9, planning target volume (PTV), and adjacent organ and vessel invasion on CT scan were evaluated by Log Rank test. Results: The median survival time was 11 months with 1-year survival rate of 36.8%. During follow-up period (range $3{\sim}20$ months, median 10 months), no significant gastrointestinal acute toxicity (RTOG grade 3) was observed. In univariate analysis, age, sex, ECOG performance score, chemotherapy, bypass surgery, radiation dose, CA 19-9 level, and adjacent organ and vessel invasion did not show any significant changes of survival rate, however, patients with PTV (80 cc showed more favorable survival rate than those with PTV>80 cc (p-value<0.05). In multivariate analysis, age younger than 65 years and PTV>80 cc showed better survival rate. Conclusion: In terms of survival, the efficacy of stereotactic radiation therapy using CK was found to be superior or similar to other recent studies achieved with conventional RT with intensive chemotherapy, high dose conformal RT, intraoperative RT (IORT), or intensity modulated RT (IMRT). Furthermore, severe toxicity was not observed. Short treatment time in relation to the short life expectancy gave patients more convenience and, finally, quality of life would be increased. Consequently, this could be regarded as an effective novel treatment modality for locally advanced, unresectable pancreas cancer. PTV would be a helpful prognostic factor for CK.

Effects of Low Dose γ-Radiation on Photosynthesis of Red Pepper (Capsicum annuum L.) and the Reduction of Photoinhibition (저선량 γ선 조사가 고추의 광합성과 광 스트레스 경감에 미치는 효과)

  • Lee, Hae-Youn;Baek, Myung-Hwa;Park, Soon-Chul;Park, Youn-Il;Kim, Jae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.2
    • /
    • pp.83-89
    • /
    • 2002
  • The effect of low dose $\gamma$ radiation on photosynthesis and the reduction of photoinhibition in red pepper plant was investigated. The seedling height leaf width and leaf length of pepper were stimulated in plants grown from seeds irradiated with the low dose of 4 Gy. The $O_2$ evolution in the 4 Gy irradiation group was 1.5 times greater than in the control. To investigate the effect of low dose $\gamma$ radiation on response to high light stress, photoinhibition was induced in leaves of pepper by illumination of high light (900 $\mu mol/m^2/s$). Pmax was decreased with increasing illumination time by 20% in the control, while hardly decreased in the 4 Gy irradiation group. The photochemical yield of PSII, estimated as Fv/Fm, was decreased with increasing illumination time by 50% after 4 hours while Fo did not change. However, Fv/Fm in the 4 Gy irradiation group was decreased by 37% of inhibition, indicating that the photoinhibition was decreased by the low dose $\gamma$ radiation. Changes in the effective quantum yield of PSII, $\Phi_{PSII}$, and 1/Fo-1/Fm, a measure of the rate constant of excitation trapping by the PSII reaction center, showed similar pattern to Fv/Fm. And NPQ was decreased after photoinhibitory treatment showing no difference between the control and the 4 Gy irradiation group. These results showed the positive effect of low dose $\gamma$ radiation on the seedling growth and the reduction of photoinhibition.

Conceptual Study of Brain Dedicated PET Improving Sensitivity

  • Shin, Han-Back;Choi, Yong;Huh, Yoonsuk;Jung, Jin Ho;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.236-240
    • /
    • 2016
  • The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation dose. In this study, we proposed a novel PET detector design that combined conical shape detector with cylindrical one to obtain high sensitivity. The sensitivity as a function of the oblique angle and the ratio of the conical to cylindrical portion was estimated to optimize the design of brain PET using Monte Carlo simulation tool, GATE. An axial sensitivity and misplacement rate by penetration of ${\gamma}$ rays were also estimated to evaluate the performance of the proposed PET. The sensitivity was improved by 36% at the center of axial FOV. This value was similar to the calculated value. The misplacement rate of conical shaped PET was about 5% higher than the conventional PET. The results of this study demonstrated the conical detector proposed in this study could provide subsequent improvement in sensitivity which could allow to design high sensitivity PET for brain imaging.

Effects of the Scattered Radiation on Image Quality and Exposure Dose in Chest Radiography (흉부X선촬영시(胸部X線撮影時) 산란선(散亂線)이 화질(畵質)과 피폭선량(被曝線量)에 미치는 영향(影響))

  • Iino, Yu;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsua;Lee, Man-Koo;An, Bong-Sun;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.27-38
    • /
    • 1993
  • To investigate relationships between image guality and exposure dose, Chest X-ray films were evaluated for the following points:how much scattered radiation can affect reduction in image quality and can be permissible diagnostically? For this purpose using a test charts and Burger's phantoms. The visual evaluation of their X-ray films and the measurements of scattered radiation were carried out. The dose of scattered radiation ranging from 20 to 25% was found to be for nothing in any diagnostic obstacle. In this range, surface doses were low of 17, 21, and $25{\mu}Gy$ for The thickness of the chest of 15, 20 and 25 cm respectively. Comparison of these high voltage X-ray films with low voltage ones showed a surface dose rate of 1:11.7. Therefore, X-ray quality, photosensitive materials(film and screen) and grid should be selected very carefully for the purpose of reduction in exposure dose.

  • PDF

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

Environmental Radiation Level in Korea($1961{\sim}1980$) (한국의 환경방사선준위(環境放射線準位)($1961{\sim}1980$))

  • Rho, Chae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • This report presents the results of the environmental radiation program at Korea Advanced Energy Research Institute (KAERI) ($37^{\circ}38'N,\;127^{\circ}05'E$) and its surroundings for the last two decades (January, 1961 through December, 1980). In the 1960s, the monthly mean levels of environmental external radiation encountered ranged from a low of 14.2 microroentgen per hour to a high of 42.2 microroentgen per hour with a mean of 21.7 microroentgen per hour, while in 1970s it ranged from a low of 12.4 microroentgen per hour to a high of 40.8 microroentgen per hour with a mean of 20.4 microroentgen per hour. It may, therefore, be said that environmental radiation dose rates remained almost unchanged for the two decades except for the second half of 1960s and the first half of 1970s during which the off-site and on-site patterns were frequently unlike in form and intensity with appreciable differences between average values. Particular results of interest with respect to the effects of the fallout gamma dose rate on environmental radiation show that elevated levels were encountered in association with the deposits of fresh debris from Chinese and Russian nuclear weapons tests in particular.

  • PDF