• Title/Summary/Keyword: high data-rate system

Search Result 1,758, Processing Time 0.038 seconds

A Review of RRAM-based Synaptic Device to Improve Neuromorphic Systems (뉴로모픽 시스템 향상을 위한 RRAM 기반 시냅스 소자 리뷰)

  • Park, Geon Woo;Kim, Jae Gyu;Choi, Geon Woo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.50-56
    • /
    • 2022
  • In order to process a vast amount of data, there is demand for a new system with higher processing speed and lower energy consumption. To prevent 'memory wall' in von Neumann architecture, RRAM, which is a neuromorphic device, has been researched. In this paper, we summarize the features of RRAM and propose the device structure for characteristic improvement. RRAM operates as a synapse device using a change of resistance. In general, the resistance characteristics of RRAM are nonlinear and random. As synapse device, linearity and uniformity improvement of RRAM is important to improve learning recognition rate because high linearity and uniformity characteristics can achieve high recognition rate. There are many method, such as TEL, barrier layer, NC, high oxidation properties, to improve linearity and uniformity. We proposed a new device structure of TiN/Al doped TaOx/AlOx/Pt that will achieve high recognition rate. Also, with simulation, we prove that the improved properties show a high learning recognition rate.

A Study on Design and Implementation of Speech Recognition System Using ART2 Algorithm

  • Kim, Joeng Hoon;Kim, Dong Han;Jang, Won Il;Lee, Sang Bae
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.2
    • /
    • pp.149-154
    • /
    • 2004
  • In this research, we selected the speech recognition to implement the electric wheelchair system as a method to control it by only using the speech and used DTW (Dynamic Time Warping), which is speaker-dependent and has a relatively high recognition rate among the speech recognitions. However, it has to have small memory and fast process speed performance under consideration of real-time. Thus, we introduced VQ (Vector Quantization) which is widely used as a compression algorithm of speaker-independent recognition, to secure fast recognition and small memory. However, we found that the recognition rate decreased after using VQ. To improve the recognition rate, we applied ART2 (Adaptive Reason Theory 2) algorithm as a post-process algorithm to obtain about 5% recognition rate improvement. To utilize ART2, we have to apply an error range. In case that the subtraction of the first distance from the second distance for each distance obtained to apply DTW is 20 or more, the error range is applied. Likewise, ART2 was applied and we could obtain fast process and high recognition rate. Moreover, since this system is a moving object, the system should be implemented as an embedded one. Thus, we selected TMS320C32 chip, which can process significantly many calculations relatively fast, to implement the embedded system. Considering that the memory is speech, we used 128kbyte-RAM and 64kbyte ROM to save large amount of data. In case of speech input, we used 16-bit stereo audio codec, securing relatively accurate data through high resolution capacity.

Study on Statistical Analysis of Measured Fluid Leakage Data and Estimation of the Leakage Rate for Power Plant Valve (발전용 밸브 유체누설 측정 데이터의 통계적 평가 및 누설량 예측 연구)

  • Lee, S.G.;Kim, D.W.;Kim, Y.S.;Park, J.H;Jeong, H.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2009
  • High temperature and pressure valves in power plant have been used for fluid flowing and leakage occurred owing to valve internal damage such as disc wear, crack and inserting of foreign objects etc. in these valves. Recently, multi-measuring technique applied both ultrasonic and acoustic method have been used for evaluation of valve internal leakage in order to raise measurement reliability. Therefore, we have performed various leakage tests using ultrasonic and acoustic measuring system and acquired leakage data for the various leakage conditions. In this study, we developed the estimation method of regression model through leakage data, and expectation method for valve opening ratio, which is directly proportion to leakage rate, using the established estimation model from the measured data, valve size and fluid pressure so as to enhance data reliability. As a result of this study, it was founded that expectation method of leakage rate by statistical analysis method is appropriate to valve leakage evaluation.

  • PDF

Performance Enhancement of Call Admission Control in an Adaptive Array Antenna System (적응형 어레이 안테나 시스템에서의 호 수락제어 알고리즘 성능 개선에 관한 연구)

  • Kim, Min-Jung;Kim, Nak-Myeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.1013-1021
    • /
    • 2004
  • In the WCDMA mobile multimedia communication system, the adaptive array antenna IS adopted to improve the performance of the system by reducing inter-user interference using antenna beam control. Usually, the interference resulted from the higher data rate users is much more significant to the lower data rate users than the other way around, so the overall performance can be enhanced by reducing the interference from higher data rate users. In order to maximize the efficiency of adaptive antenna operation, an optimal call admission control, especially during handoff, adaptive to the data rates is a critical problem. In this paper, We propose a call admission control algorithm based on the Soft QoS concept for the efficient processing of the handoff of higher data rate calls, and an adaptive handoff control mechanism according to the data rates. The proposed algorithm has been evaluated by computer simulation that it accommodates high data rate users among many lower data rate users much better, and the average call blocking probability for lower rate users becomes much lower than the conventional call admission control algorithm.

Real Time Tilt Servo Control of The Holographic Data Storage System (홀로그래픽 정보 저장 장치에서의 실시간 틸트 서보 제어)

  • Moon, Jae-Hee;Kim, Sang-Hoon;Yang, Jun-Ho;Yang, Hyun-Seok;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • The purpose of this paper is real time tilt servo control of the holographic data storage system. Holographic data storage device is a next generation data storage device with high storage density, high transfer rate and short access time. This device is very sensitive to a disturbance due to the enormous storage density. As to the recording material changed disc type, the media continuously vibrates as the disc rotates. When disc rotates, deviation, eccentricity and unbalance disturbance are occurred. This disturbances cause disc tilt, finally reference beam does not illuminates to correct incidence angle. Therefore real time tilt servo control is essential. In this paper, the algorithm is proposed to make real time tilt detection in angle multiplexing of the holographic data storage system with an additional servo beam and the experiments are performed.

  • PDF

Direct Sequence Spread Spectrum Transmitter using FPGAs

  • Abhijit S. Pandya;Souza, Ralph-D′;Chae, Gyoo-Yong
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.2
    • /
    • pp.76-79
    • /
    • 2004
  • The DS-SS (Direct Sequence Spread Spec1nun) transmitter is part of a low data rate (∼150 kbps - burst rate and 64 bps - average data rate) wireless communication system. It is traditionally implemented using Digital Signal processing chip (DSP). However, with rapid increase in variety of services through cell phones, such as, web access, video transfer, online games etc. demand for higher rate is increasing steadily. Since the chip rate and thereby the sampling rate requirements of the system are fairly high, the transmitter should implemented using Field programmable Gate Arrays FPGAs instead of a DSP. This paper shows the steps taken to get a working prototype of the transmitter unit on a FPGA based platform.

A Study on the Capacity Enhancement of HDR-WPAN System (HDR-WPAN 시스템의 용량증대 방안 연구)

  • Kang Chul-Gyu;Oh Yong-Taek;Kim Jae-Young;Cho Sung-Eon;Oh Chang-Heon
    • Journal of Digital Contents Society
    • /
    • v.5 no.4
    • /
    • pp.306-310
    • /
    • 2004
  • In this paper, we proposed a capacity enhancement method using TCM-128QAM modulation and bandwidth extension of 25MHz in HDR-WPAN (high data rate wireless personal area network) system. In case using TCM-128 QAM modulation scheme, we can obtain maximum 66Mbps transmission rate in bandwidth of 15MHz. If extend bandwidth by 25MHz and roll-off coefficient ${\alpha}=0.35$, we can obtain maximum 110Mbps transmission rate. These results are confirmed through PSD(power spectrum density) analysis and BER (bit error rate) performance.

  • PDF

Antenna Selection Scheme Using Noncoherent Receivers for Off-Body High Data Rate WBAN (신체 외부 고속 통신에서 Noncoherent 수신기 기반의 안테나 선택 기법)

  • Park, Jong-Seok;Hwang, Jae-Ho;Jang, Sung-Jeen;Kim, Jae-Moung;Lee, Hyung-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.88-97
    • /
    • 2009
  • As the development of wireless techniques, transmission technology of body area network plays an important role in realizing a welfare society by combining IT and BT when applying to vehicles. Off-body WBAN (Wireless Body Area Network) systems for video data transmission require low battery consumption and high data rate. To satisfy the requirement, UWB has been considered as a promising candidate for high rate WBAN. This paper introduces an antenna selection technique for ultra-wideband based off-body WBAN system with low complexity. In this paper, we propose an antenna selection scheme using non-coherent receiver for off-body high data rate WBAN system. The proposed receiver antenna selection method takes advantage of the characteristic of BPPM (Binary Pulse Position Modulation). With the property of BPPM, this scheme calculates the approximate SNR of the received signal with non-coherent receiver.

  • PDF

A study on Anwareness for Improvement of Oriental Medical Care System in Community People (한방의료개선에 대한 지역사회주민의 의식조사)

  • Bae Joo-Han;Nam Chul-Hyun;Wie Gwang-Bog
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.1 no.1
    • /
    • pp.126-136
    • /
    • 1997
  • To procide basic data for improvement of oriental medical care system, the questionnaire interview was carried out with community peoples, over 20 years old, selected randomly in Seoul, Pusan, Taegu and Taejon err. from 10th Mar. to 20th Apr. 1996. The result were summarized as follows: 1. In the general characteristics of subjects, the highest portion of each part was 52.4% of male, 22.4% of thirties, 37.1% of college graduates, 19.1% of married, 30.6% of town dwellers, 63.3% of muddle social class, 26.6% of housewife, 19.3% of student, 16.6% officer and 11.6% of professional technician. 2. The portion of subjects agree to open oriental clinic in western medicine hospital was 60.0%, that of disagreement was 20.1%, Among 60.0% of agreement group, the high rate was showed in female, fifties, middle school graduates, unemployed, middle social level. 3. The rate of positive responses in system of a herb specialist was 64.7%, that of negative responses was 11.6%. Among positive responses, the groups of high rate were male. twenties, above college graduates, student, middle-high social level and city dwellers. 4. In the question whether a pack of herb medicine should be included in medical insurance or not, the rate of agreement was 74.3%, that of disagreement was 4.1%. Amount agreement subjects, the high rate was showed in male, young age, high educated, city dwellers, professional technician middle social class. 5. In the cost of oriental medical care, the portion was divided by 70.3% of expensiveness,25.6% of moderate, 4.1% of low price. among 70.3% of high price, the high rate was in female, forties, agrolivestock-fishery, and town dwellers. 6. In the question what the herb doctor should do for the improvement of oriental medicine, the highest rate was 54.2% in further study. The next was 23.0% in need of western medical and 9.1% in no complain in present situation. Among 54.2% of further study, the high rate was showed in male, forties, high school graduate, profession technician, high social level, christian, married and city dwellers. 7. About institution of oriental care, 86.8% of subjects answered to need of improvement, 8.0% of them replied no problem as present. Amount 86.8% of subjects, the high rate was showed in male, twenties, above college graduate, sales, singles, high social level and city dwellers. 8. About necessity of western medical care instrument in oriental medical hospital, the rate of sightly need was 47.5%, inevitably need was 37.7%, no need was 6.3%, the Positive subjects were showed high rate in male, officer, singer, the younger age, the higher educated, better social level and city dwellers. These results might be useful information for establishing of oriental medical care policies, which open oriental medical clinic in western medical hospital, equip western medical care instrument in oriental medical hospital, improve oriental medical care instrument carry out a herb specialist system, balance the resonable medical care cost and effort for further study & research on oriental medicine to satisfy increasing need of oriental medicine.

  • PDF

Design and Implementation of Variable-Rate QPSK Demodulator from Data Flow Representation

  • Lee, Seung-Jun
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.139-144
    • /
    • 1998
  • This paper describes the design of a variable rate QPSK demodulator for digital satellite TV system. This true variable-rate demodulator employs a unique architecture to realize an all digital synchronization and detection algorithm. Data-flow based design approach enabled a seamless transition from high level design optimization to physical layout. The demodulator has been integrated with Viterbi decoder, de-interleaver, and Ree-Solomon decoder to make a single chip Digital Video Broadcast (DVB) receiver. The receiver IC has been fabricated with a 0.5mm CMOS TLM process and proved fully functional in a real-world set-up.

  • PDF