• 제목/요약/키워드: high current cable

검색결과 302건 처리시간 0.031초

DC 급전케이블 지락사고 보호방안에 관한 연구 (The study on the prevention of DC feeder line cable grounding fault)

  • 박지수;송중호;박정욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석 (Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station)

  • 김보경;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.245-250
    • /
    • 2017
  • 케이블은 설치하여 동작함과 동시에 열화과정이 진행된다. 고압전력케이블 시스템에 있어, 케이블의 절연층 및 방식층의 절연상태뿐만 아니라 케이블을 연결하는 단말부 및 접속부의 절연상태도 함께 감시하여야 케이블 시스템의 절연상태를 종합 관리할 수 있다. 케이블 시스템(케이블 자체 및 접속재)의 상태가 계속 나빠지는 경우, XLPE의 절연 파괴현상으로 인한 화재가 발생한다. 우리는 케이블시스템의 절연 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국 서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 이 논문에서, 이 장비를 사용하여 케이블에 흐르는 누설전류를 추출하여 누설전류의 표준편차를 계산하여 분석한 결과를 제시한다. 정해진 누설 전류의 표준 편차값이 기준값 미만이면 안전하지만. 그 이상이면 케이블시스템의 단말부 및 접속부의 절연상태가 나쁜 것으로 판단하고, 새로운 케이블시스템의 단말부 및 접속부로 대체함으로써 전력공급 중단으로 인한 전력설비의 중단사고를 미연에 방지할 수 있다.

초전도 케이블용 고온초전도 선재의 개발 및 특성평가 (Development and Characterization of High Temperature Superconducting Wire for Superconducting Cable System)

  • 민병진;이재훈;김영순;이헌주;문승현
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.151-156
    • /
    • 2015
  • In order to improve the properties of high-temperature superconducting wire for superconducting cable system, we optimized the electro-polishing (EP), ion-beam assisted deposition (IBAD), superconducting (SC) layer, and baking (heat) treatment. The buffer layer was deposited on electro-polished substrate with RMS roughness ($R_{RMS}$) less than 5 nm. The IBAD process was carried out at $V_{beam}$: 1100 V and $V_{accel}$: 850 V that resulted in highly crystalline film of $LaMnO_3$. Chemical composition of SC layer is key to higher critical current, and we found that composition can be determined by surface color of SC layer. We adopt a proprietary contorl system based on RGB analysis of the surface and achieved critical current of 150 A/4 mm-width. The proposed baking treatment resulted in decreasing of about 10% of fraction defects.

대전류 통전용 Bi-2212/Ag 러더포드 케이블링 공정 연구 (Study on Bi-2212/Ag HTS Rutherford cabling process for high current capacity)

  • 하동우;김상철;한일용;오상수;오재근;이정훈;송규정;이남진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.238-239
    • /
    • 2007
  • The important merit of Bi-2212/Ag wire is to apply cable as round wire state. Bi-2212 high Tc superconducting wires were fabricated in order to apply Rutherford cable near the future. Various Ag ratio from 0.22 to 0.42 of Ag tubes for PID (powder-In-Tube) process were used to investigate the workability and to prevent breakage of filaments during drawing. KERI and Nexans Korea manufactured Rutherford cabling machine by ourselves. Rutherford cables with 20 - 30 strands could be fabricated by this machine. The shape of Rutherford cables were satisfied. The critical current of Bi2212/Ag round wire with 847 filaments showed 400 A at 4.2K and self field.

  • PDF

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

ACCELEROMETER SELECTION CONSIDERATIONS Charge and Integral Electronic Piezo Electric

  • Lally, Jim
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.1047-1051
    • /
    • 2004
  • Charge amplifier systems benefit from the very wide dynamic range of PE accelerometers by offering flexibility in adjusting the electrical output characteristics such as sensitivity and range. They are well suited for operation at high temperatures. Modern charge systems feature improved low noise operation, simplified digital controls, and dual mode operation for operation with charge or IEPE voltage mode sensors. high impedance circuitry is not well suited for operation in adverse field or factory environments. The resolution of a PE accelerometer may not be specified or known since noise is a system consideration determined by cable length and amplifier gain. IEPE accelerometrs operate from a constant current power source, provide a high-voltage, low-impedance, fixed mV/g output. They operate through long, ordinary, coaxial cable in adverse environments without degradation of signal quality. They have limited high temperature range. IEPE sensors are simple to operate. Both resolution and operating range are defined specifications. Cost perchannel is lower compared to PE systems since low-noise cable and charge amplifiers are not required.

  • PDF

제작방법에 따른 전력케이블용 폴리에틸렌 박막의 전기전도특성 (The Electrical Conduction Properties of Polyethylene Thin Film for Power Cable with Manufacturing Methods)

  • 조경순;이용우;이수원;홍진웅
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권5호
    • /
    • pp.453-460
    • /
    • 1997
  • In order to investigate the electrical conduction properties of polyethylene thin film for power cable with manufacturing methods, the thickness of specimen was the 30, 100[${\mu}{\textrm}{m}$] of LDPE and 200[${\mu}{\textrm}{m}$] of XLPE were manufactured. The experimental condition for conduction properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and the electric field from 1$\times$10$^3$to 5$\times$10$^{6}$ [V/cm]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high electric field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy. At low electric field, the XLPE showed dominant electrical conduction properties by thermal excitation, and transformation of the electron was resisted by the crystal at high electric field.

  • PDF

한전 초전도전력케이블 냉각시스템 성능시험 (Performance Test of Cooling System for the KEPCO HTS Power Cable)

  • 양형석;김동락;손송호;임지현;최하옥;이병섭;최연석;류희석;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2206-2210
    • /
    • 2007
  • As a power transmission line supplying power to a densely populated city, the high temperature superconducting (HTS) cable is expected to one of the most effective cables with a compact size because of its high current density. The verification of HTS power cable system have been progressed by KEPRI. A cooling system for a 3-phase 100m HTS power cable with 22.9kV/1.25kA was installed and tested at KEPCO's Gochang power testing center in Korea. The system consists of a liquid nitrogen decompression cooling system with a cooling capacity of 3kW and a closed circulation system of subcooled liquid nitrogen. Several performance tests of the cable system with respect to the cooling such as cooling capacity, heat load and temperature stability, were performed at several temperatures. Thermal cycle test, cool-down to liquid nitrogen temperature and warm-up to room temperature, was also performed to investigate thermal cycle influences. The outline of the installed cooling system and performance test results are presented in this paper.

  • PDF

고온초전도 직류 케이블용 절연재료인 PPLP의 직류 및 임펄스 절연 특성 (DC and Impulse Insulation Characteristics of PPLP for HTS DC Cable)

  • 김우진;방만식;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제26권7호
    • /
    • pp.545-549
    • /
    • 2013
  • To realize the high-Tc superconducting (HTS) DC cable system, it is important to study not only high current capacity and low loss of conductor but also optimum electrical insulation at cryogenic temperature. A model HTS DC cable system consists of a HTS conductor, semi-conductor, cooling system and insulating materials. Polypropylene laminated paper (PPLP) has been widely adopted as insulating material for HTS machines. However, the fundamental insulation characteristics of PPLP for the development of HTS DC cable have not been revealed satisfactorily until now. In this paper, we will discuss mainly on the breakdown characteristics of 3 sheets PPLP in liquid nitrogen ($LN_2$). The characteristics of the diameter, location of butt-gap, distance between butt-gap length, pressure effect, polarity effect under DC and impulse voltage were studied. Also, the DC polarity reversal breakdown voltage of mini-model cable was measured in $LN_2$ under 0.4 MPa.