• 제목/요약/키워드: high background radiation area

검색결과 32건 처리시간 0.02초

Optical Characterizations of TlBr Single Crystals for Radiation Detection Applications

  • Oh, Joon-Ho;Kim, Dong Jin;Kim, Han Soo;Lee, Seung Hee;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.167-171
    • /
    • 2016
  • Background: TlBr is of considerable technological importance for radiation detection applications where detecting high-energy photons such as X-rays and ${\gamma}$-rays are of prime importance. However, there were few reports on investigating optical properties of TlBr itself for deeper understandings of this material and for making better radiation detection devices. Thus, in this paper, we report on the optical characterizations of TlBr single crystals. Spectroscopic ellipsometry (SE) and photoluminescence (PL) measurements at RT were performed for this work. Materials and Methods: A 2-inch TlBr single crystalline ingot was grown by using the vertical Bridgman furnace. SE measurements were performed at RT within the photon energy range from 1.1 to 6.5 eV. PL measurements were performed at RT by using a home-made PL system equipped with a 266 nm-laser and a spectrometer. Results and Discussion: Dielectric responses from SE analysis were shown to be slightly different among the different samples possibly due to the different structural/optical properties. Also from the PL measurements, it was observed that the peak intensities of the middle samples were significantly higher than those of the other two samples. With the given values for permittivity of free space (${\varepsilon}_0=8.854{\times}10^{-12}F{\cdot}m^{-1}$), thickness (d = 1 mm), and area ($A=10{\times}10mm^2$) of the TlBr sample, capacitances of TlBr were 6.9 pF (at $h{\nu}=3eV$) and 4.4 pF (at $h{\nu}=6eV$), respectively. Conclusion: SE and PL measurement and analysis were performed to characterize TlBr samples from the optical perspective. It was observed that dielectric responses of different TlBr samples were slightly different due to the different material properties. PL measurements showed that the middle sample exhibited much stronger PL emission peaks due to the better material quality. From the SE analysis, optical, dielectric constants were extracted, and calculated capacitances were in the few pF range.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

Treatment of Extremely High Risk and Resistant Gestational Trophoblastic Neoplasia Patients in King Chulalongkorn Memorial Hospital

  • Oranratanaphan, Shina;Lertkhachonsuk, Ruangsak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.925-928
    • /
    • 2014
  • Background: Gestational trophoblastic neoplasia (GTN) is a spectrum of disease with abnormal trophoblastic proliferation. Treatment is based on FIGO stage and WHO risk factor scores. Patients whose score is 12 or more are considered as at extremely high risk with a high likelihood of resistance to first line treatment. Optimal therapy is therefore controversial. Objective: This study was conducted in order to summarize the regimen used for extremely high risk or resistant GTN patients in our institution the in past 10 years. Materials and Methods: All the charts of GTN patients classified as extremely high risk, recurrent or resistant during 1 January 2002 to 31 December 2011 were reviewed. Criteria for diagnosis of GTN were also assessed to confirm the diagnosis. FIGO stage and WHO risk prognostic score were also re-calculated to ensure the accuracy of the information. Patient characteristics were reviewed in the aspects of age, weight, height, BMI, presenting symptoms, metastatic area, lesions, FIGO stage, WHO risk factor score, serum hCG level, treatment regimen, adjuvant treatments, side effects and response to treatment, including disease free survival. Results: Eight patients meeting the criteria of extremely high risk or resistant GTN were included in this review. Mean age was 33.6 years (SD=13.5, range 17-53). Of the total, 3 were stage III (37.5%) and 5 were stage IV (62.5%). Mean duration from previous pregnancies to GTN was 17.6 months (SD 9.9). Mean serum hCG level was 864,589 mIU/ml (SD 98,151). Presenting symptoms of the patients were various such as hemoptysis, abdominal pain, headache, heavy vaginal bleeding and stroke. The most commonly used first line chemotherapeutic regimen in our institution was the VAC regimen which was given to 4 of 8 patients in this study. The most common second line chemotherapy was EMACO. Adjuvant radiation was given to most of the patients who had brain metastasis. Most of the patients have to delay chemotherapy for 1-2 weeks due to grade 2-3 leukopenia and require G-CSF to rescue from neutropenia. Five form 8 patients were still survived. Mean of disease free survival was 20.4 months. Two patients died of the disease, while another one patient died from sepsis of pressure sore wound. None of surviving patients developed recurrence of disease after complete treatment. Conclusions: In extremely high risk GTN patients, main treatment is multi-agent chemotherapy. In our institution, we usually use VAC as a first line treatment of high risk GTN, but since resistance is quite common, this may not suitable for extremely high risk GTN patients. The most commonly used second line multi-agent chemotherapy in our institution is EMA-CO. Adjuvant brain radiation was administered to most of the patients with brain metastasis in our institution. The survival rate is comparable to previous reviews. Our treatment demonstrated differences from other institutions but the survival is comparable. The limitation of this review is the number of cases is small due to rarity of the disease. Further trials or multicenter analyses may be considered.

Hazards Caused by UV Rays of Xenon Light Based High Performance Solar Simulators

  • Dibowski, Gerd;Esser, Kai
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.237-245
    • /
    • 2017
  • Background: Solar furnaces are used worldwide to conduct experiments to demonstrate the feasibility of solar-chemical processes with the aid of concentrated sunlight, or to qualify high temperature-resistant components. In recent years, high-flux solar simulators (HFSSs) based on short-arc xenon lamps are more frequently used. The emitted spectrum is very similar to natural sunlight but with dangerous portions of ultraviolet light as well. Due to special benefits of solar simulators the increase of construction activity for HFSS can be observed worldwide. Hence, it is quite important to protect employees against serious injuries caused by ultraviolet radiation (UVR) in a range of 100 nm to 400 nm. Methods: The UV measurements were made at the German Aerospace Center (DLR), Cologne and Paul-Scherrer-Institute (PSI), Switzerland, during normal operations of the HFSS, with a high-precision UV-A/B radiometer using different experiment setups at different power levels. Thus, the measurement results represent UV emissions which are typical when operating a HFSS. Therefore, the biological effects on people exposed to UVR was investigated systematically to identify the existing hazard potential. Results: It should be noted that the permissible workplace exposure limits for UV emissions significantly exceeded after a few seconds. One critical value was strongly exceeded by a factor of 770. Conclusion: The prevention of emissions must first and foremost be carried out by structural measures. Furthermore, unambiguous protocols have to be defined and compliance must be monitored. For short-term activities in the hazard area, measures for the protection of eyes and skin must be taken.

Atmospheric Dispersion Characteristics of Radioactive Materials according to the Local Weather and Emission Conditions

  • An, Hye Yeon;Kang, Yoon-Hee;Song, Sang-Keun;Kim, Yoo-Keun
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.315-327
    • /
    • 2016
  • Background: This study evaluated the atmospheric dispersion of radioactive material according to local weather conditions and emission conditions. Materials and Methods: Local weather conditions were defined as 8 patterns that frequently occur around the Kori Nuclear Power Plant and emission conditions were defined as 6 patterns from a combination of emission rates and the total number of particles of the $^{137}Cs$, using the WRF/HYSPLIT modeling system. Results and Discussion: The highest mean concentration of $^{137}Cs$ occurred at 0900 LST under the ME4_1 (main wind direction: SSW, daily average wind speed: $2.8ms^{-1}$), with a wide region of its high concentration due to the continuous wind changes between 0000 and 0900 LST; under the ME3 (NE, $4.1ms^{-1}$), the highest mean concentration of $^{137}Cs$ occurred at 1500 and 2100 LST with a narrow dispersion along a strong northeasterly wind. In the case of ME4_4 (S, $2.7ms^{-1}$), the highest mean concentration of $^{137}Cs$ occurred at 0300 LST because $^{137}Cs$ stayed around the KNPP under low wind speed and low boundary layer height. As for the emission conditions, EM1_3 and EM2_3 that had the maximum total number of particles showed the widest dispersion of $^{137}Cs$, while its highest mean concentration was estimated under the EM1_1 considering the relatively narrow dispersion and high emission rate. Conclusion: This study showed that even though an area may be located within the same radius around the Kori Nuclear Power Plant, the distribution and levels of $^{137}Cs$ concentration vary according to the change in time and space of weather conditions (the altitude of the atmospheric boundary layer, the horizontal and vertical distribution of the local winds, and the precipitation levels), the topography of the regions where $^{137}Cs$ is dispersed, the emission rate of $^{137}Cs$, and the number of emitted particles.

Leu432Val Polymorphism of CYP1B1 is Not Associated with Squamous Cell Carcinoma of Esophagus - a Case-Control Study from Kashmir, India

  • Shah, Idrees Ayoub;Mehta, Promila;Lone, Mohd Maqbool;Dar, Nazir Ahmad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권13호
    • /
    • pp.5337-5341
    • /
    • 2015
  • Background: Individual susceptibility to cancer has been attributed to polymorphisms in xenobiotic metabolizing genes. To evaluate the association of the Leu432Val polymorphism of cytochrome P4501B1 (CYP1B1) with esophageal squamous cell carcinoma (ESCC), we conducted a case control study in Kashmir, India, an area with a relatively high incidence of ESCC. Materials and Methods: We recruited 404 histopathologically confirmed ESCC cases, and an equal number of controls, individually matched for sex, age and district of residence to respective cases. Information was obtained on various dietary, lifestyle and environmental factors in face to face interviews, using a structured questionnaire, from each subject. Genotypes were analysed by polymerase chain reaction, restriction fragment length polymorphism and sequencing of randomly selected samples. Conditional logistic regression models were used to calculate odds ratios (ORs) and 95% confidence intervals (95% CIs). Results: Among the three possible variants, we did not find any Leu432Leu genotype of CYP1B1 in the study population and the genotypic distribution of Val432Val and Leu432Val carriers was nearly equal in both cases (89.6% and 10.4%) and controls (88.9% and 11.1%) respectively. We did not find any risk associated with this polymorphism in the current study (OR = 0.64; 95% CI: 0.55 - 1.64). Conclusions: The study indicates that (Leu432Val) polymorphism of CYP1B1, is not associated with ESCC risk. However, replicative studies with larger sample size are needed to substantiate the findings.

Assessment of Environmental Radioactivity Surveillance Results around Korean Nuclear Power Utilization Facilities in 2017

  • Kim, Cheol-Su;Lee, Sang-Kuk;Lee, Dong-Myung;Choi, Seok-Won
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.118-126
    • /
    • 2019
  • Background: Government conducts environmental radioactivity surveillance for verification purpose around nuclear facilities based on the Nuclear Safety Law and issues a surveillance report every year. This study aims to evaluate the short and the long-term fluctuation of radionuclides detected above MDC and their origins using concentration ratios between these radionuclides. Materials and Methods: Sample media for verification surveillance are air, rainwater, groundwater, soil, and milk for terrestrial samples, and seawater, marine sediment, fish, and seaweed for marine samples. Gamma-emitting radionuclides including $^{137}Cs$, $^{90}Sr$, Pu, $^3H$, and $^{14}C$ are evaluated in these samples. Results and Discussion: According to the result of the environmental radioactivity verification surveillance in the vicinity of nuclear power facilities in 2017, the anthropogenic radionuclides were not detected in most of the environmental samples except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples. Radioactivity concentration ratios between the anthropogenic radionuclides ($^{137}Cs/^{90}Sr$, $^{137}Cs/^{239+240}Pu$, $^{90}Sr/^{239+240}Pu$) were similar to those reported in the environmental samples, which were affected by the global fallout of the past nuclear weapon test, and Pu atomic ratios ($^{240}Pu/^{239}Pu$) in the terrestrial sample and marine sample showed significant differences due to the different input pathway and the Pu source. Radioactive iodine ($^{131}I$) was detected at the range of < $5.6-190mBq{\cdot}kg-fresh^{-1}$ in the gulfweed and sea trumpet collected from the area of Kori and Wolsong intake and discharge. A high level of $^3H$ was observed in the air (Sangbong: $0.688{\pm}0.841Bq{\cdot}m^{-3}$) and the precipitation (Meteorology Post: $199{\pm}126Bq{\cdot}L^{-1}$) samples of the Wolsong nuclear power plant (NPP). $^3H$ concentration in the precipitation and pine needle samples showed typical variation pattern with the distance and the wind direction from the stack due to the gaseous release of $^3H$ in Wolsong NPP. Conclusion: Except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples, anthropogenic radionuclides were below MDC in most of the environmental samples. Overall, no unusual radionuclides and abnormal concentration were detected in the 2017's surveillance result for verification. This research will be available in the assessment of environment around nuclear facilities in the event of radioactive material release.

Extragalactic Sciences from SPICA/FPC-S

  • 정웅섭;;임명신;이형목;이정은;;;;이대희;표정현;박성준;문봉곤;박귀종;박영식;한원용;남욱원
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.36.2-36.2
    • /
    • 2013
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. The focal plane instruments onboard SPICA will enable us to resolve many astronomical key issues from the formation and evolution of galaxies to the planetary formation. The FPC-S (Focal Plane Camera - Sciecne) is a near-infrared instrument proposed by Korea as an international collaboration. Owing to the capability of both low-resolution imaging spectroscopy and wide-band imaging with a field of view of $5^{\prime}{\times}5^{\prime}$, it has large throughput as well as high sensitivity for diffuse light compared with JWST. In order to strengthen advantages of the FPC-S, we propose the studies of probing population III stars by the measurement of cosmic near-infrared background radiation and the star formation history at high redshift by the discoveries of active star-forming galaxies. In addition to the major scientific targets, to survey large area opens a new parameter space to investigate the deep Universe. The good survey capability in the parallel imaging mode allows us to study the rare, bright objects such as quasars, bright star-forming galaxies in the early Universe as a way to understand the formation of the first objects in the Universe, and ultra-cool brown dwarfs. Observations in the warm mission will give us a unique chance to detect high-z supernovae, ices in young stellar objects (YSOs) even with low mass, the $3.3{\mu}$ feature of shocked circumstance in supernova remnants. Here, we report the current status of SPICA/FPC project and its extragalactic sciences.

  • PDF

대기 누출 방사성물질 선원 위치 추적을 위한 3차원 궤적모델 개발 (Development of Three-Dimensional Trajectory Model for Detecting Source Region of the Radioactive Materials Released into the Atmosphere)

  • 서경석;박기현;민병일;김소라;양병모
    • Journal of Radiation Protection and Research
    • /
    • 제41권1호
    • /
    • pp.31-39
    • /
    • 2016
  • 연구배경: 우리나라를 포함한 중국, 대만, 북한, 일본 등에서 원전, 재처리시설과 같은 원자력시설의 증가에 따라 주변국 핵활동 분석의 종합적 대책이 필요하다. 우리나라와 포괄적핵실험금지조약기구(Comprehensive Nuclear-Test-Ban Treaty Organization, CTBTO)는 동북아시아 지역에서 핵종 탐지소를 운영 중으로, 핵종탐지 장비에서 특이 값 측정시 모니터링 자료의 분석과 더불어 배출원 탐색모델을 이용하여 핵종의 기원이 어디인지 추정하고 평가하는 것은 주변국 핵활동에 대한 감시 및 안전성 확보 측면에서 중요하다. 재료 및 방법: 주변국의 은밀한 핵활동 시 방사성핵종의 기원을 추정하기 위하여 3차원 전진/후진형 궤적모델을 개발하였다. 개발된 궤적모델은 궤적 미분방정식을 유한차분법을 이용한 방법으로 주어진 바람자료를 이용하여 방사성핵종의 방출지점으로부터 입자의 궤적을 순차적으로 찾아가는 전진형 모델과 시간 역산으로 방출기원을 추정하는 후진형 모델로 구성되었다. 결과 및 논의: 개발된 궤적모델의 검증을 위하여 체르노빌 사고 당시 측정된 농도자료를 이용하였다. 검증결과 관측지점의 농도가 높게 측정된 지점과 방출기원에서 가까운 지역으로부터 시간 역산의 방출지점을 추정한 결과의 정확도가 높았다. 3차원 궤적모델은 방출시간, 방출높이, 방출간격 등의 변수에 의해 계산결과가 달라지는 불확도를 내포하고 있는데, 이러한 궤적모델의 불확도를 최소화하기 위해 한국원자력연구원에서 개발한 대기확산모델(long-range accident dose assessment system, LADAS)를 이용하여 fields of regards (FOR) 기법에 의해 오염물 방출영역을 추정한바 신뢰성 있는 결과를 얻었다. 결론: 본 연구를 통하여 개발된 배출원 탐색모델은 주변국의 은밀한 핵활동 시 핵종 탐지장비와 연계하여 방사성핵종의 방출지역과 기원을 파악하여 우리나라의 핵종탐지 능력을 향상하고 핵활동 및 방사선 안전 분야에서 주도적 역할을 할 수 있을 것으로 생각된다.

CT Based 3-Dimensional Treatment Planning of Intracavitary Brachytherapy for Cancer of the Cervix : Comparison between Dose-Volume Histograms and ICRU Point Doses to the Rectum and Bladder

  • Hashim, Natasha;Jamalludin, Zulaikha;Ung, Ngie Min;Ho, Gwo Fuang;Malik, Rozita Abdul;Ee Phua, Vincent Chee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5259-5264
    • /
    • 2014
  • Background: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT). Materials and Methods: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose ($D_{Max}$) to rectum was the highest recorded dose at one of these five points. Using the HDRplus 2.6 brachyhtherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded ($D_{2cc}$) for all individual fractions. The mean $D_{2cc}$ of rectum was compared to the means of ICRU rectal point and rectal $D_{Max}$ using the Student's t-test. The mean $D_{2cc}$ of bladder was compared with the mean ICRU bladder point using the same statistical test. The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (${\alpha}/{\beta}$ value of 10 Gy for target, 3 Gy for organs at risk). Results: The total prescribed dose was $77.5Gy{\alpha}/{\beta}10$. The mean dose to the rectum was $4.58{\pm}1.22Gy$ for $D_{2cc}$, $3.76{\pm}0.65Gy$ at $D_{ICRU}$ and $4.75{\pm}1.01Gy$ at $D_{Max}$. The mean rectal $D_{2cc}$ dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48-1.19Gy). The mean EQD2 was $68.52{\pm}7.24Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$, $61.71{\pm}2.77Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$ and $69.24{\pm}6.02Gy_{{\alpha}/{\beta}3}$ at $D_{Max}$. The mean ratio of $D_{2cc}$ rectum to $D_{ICRU}$ rectum was 1.25 and the mean ratio of $D_{2cc}$ rectum to $D_{Max}$ rectum was 0.98 for all individual fractions. The mean dose to the bladder was $6.00{\pm}1.90Gy$ for $D_{2cc}$ and $5.10{\pm}2.03Gy$ at $D_{ICRU}$. However, the mean $D_{2cc}$ dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25Gy). The mean EQD2 was $81.85{\pm}13.03Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$ and $74.11{\pm}19.39Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$. The mean ratio of $D_{2cc}$ bladder to $D_{ICRU}$ bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose. Conclusions: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the $D_{2cc}$ and rectal $D_{Max}$ for $D_{2cc}$. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the $D_{2cc}$.