• Title/Summary/Keyword: high SNR

Search Result 673, Processing Time 0.024 seconds

Extended Target State Vector Estimation using AKF (적응형 칼만 필터를 이용한 확장 표적의 상태벡터 추정 기법)

  • Cho, Doo-Hyun;Choi, Han-Lim;Lee, Jin-Ik;Jeong, Ki-Hwan;Go, Il-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.507-515
    • /
    • 2015
  • This paper proposes a filtering method for effective state vector estimation of highly maneuvering target. It is needed to hit the point called 'sweet spot' to increase the kill probability in missile interception. In paper, a filtering method estimates the length of a moving target tracked by a frequency modulated continuous wave (FMCW) radar. High resolution range profiles (HRRPs) is generated from the radar echo signal and then it's integrated into proposed filtering method. To simulate the radar measurement which is close to real, the study on the properties of scattering point of the missile-like target has been conducted with ISAR image for different angle. Also, it is hard to track the target efficiently with existing Kalman filters which has fixed measurement noise covariance matrix R. Therefore the proposed method continuously updates the covariance matrix R with sensor measurements and tracks the target. Numerical simulations on the proposed method shows reliable results under reasonable assumptions on the missile interception scenario.

Development of intrusion detection technique using fiber optic ROTDR sensor (광섬유 ROTDR 센서를 이용한 침입 탐지기법의 개발)

  • Baik, Se-Jong;Kwon, Il-Bum;Chung, Chul;Yu, Jae-Wang
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2002
  • The developing of buried fiber optic sensor with high sensitivity and broad-area detecting intruders is carried out using fiber optic ROTDR(Rayleigh Optical Time Domain Reflectometry). The sensing part was designed to be able to broad-area detect intrusion effect per optical fiber length under ground. The bending light losses in optical fibers are investigated by commercial mini ROTDR with wavelength $1.55{\mu}m$, distance range 5km, pulse width 20ns, SNR=5.7. The sensing fibers are selected as the common telecommunication fibers are the 1.5mm, 3.5 mm outer diameter, 4km each length fiber products. Experiments were investigate the characteristics of signal sensitivity according to applied intrusion weight. The relation between the applied weight and the bending loss was almost linear, and broad-area detect intrusion effects are the 2m resolution and $1.3m^2$ per optical fiber length respectively. The light loss by the applied weight on fiber was 0.17 dB/kg. that the sensitivity of the optical fiber sensor was sufficient to detect intruders passing over the buried optical fiber.

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

A Initial Channel Estimation Method Based on Extensive Preamble Utilization in MB-OFDM UWB System (프리엠블 확장 사용 기반 MB-OFDM UWB용 채널 추정 방식)

  • Jeong, Jin-Doo;Jin, Yong-Sun;Chong, Jong-Wha
    • 전자공학회논문지 IE
    • /
    • v.48 no.1
    • /
    • pp.30-35
    • /
    • 2011
  • In this paper, we propose a method to improve the performance of initial channel estimation (CE) for the multiband-OFDM (MB-OFDM) UWB. The performance of the initial CE can be generally improved as increasing the number of the used preamble symbols. The MB-OFDM specification presents two CE symbols per band in preamble format. The performance of CE estimation with two CE symbols may be satisfied in relatively high sensitivity -77.5 and -72.5 dBm for 200 Mbps and 480 Mbps data rate, respectively, but can not be enough in the degraded 55 Mbps and 110 Mbps sensitivities such as -83.5 and -80.5 dBm, respectively. A method proposed in this paper achieves the performance improvement by extending CE estimation region to packet synchronization (PS) symbols and frame synchronization (FS) symbols including two CE symbols. This can improve the CE performance in the degraded SNR and increase the link-margin by reducing the error rate in physical-layer header. The link-margin improvement obtained by the proposed CE preamble can induce the decrease of error-rate in physical-layer header and increase of communication throughput. Simulation results for the proposed initial method show that the performance is improved by about 0.7 dB at 10-4 bit-error-rate using '4' symbols than initial method using only two CE symbols.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

An Enhanced Frequency Synchronization Algorithm for 3GPP LTE FDD/TDD Dual Mode Downlink Receiver (3GPP LTE FDD/TDD 듀얼 모드 하향 링크 수신기를 위한 개선된 주파수 동기 알고리즘)

  • Shim, Myung-Jun;Jang, Jun-Hee;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.103-112
    • /
    • 2010
  • In this paper, we propose a coarse and fine frequency synchronization method which is suitable for the 3GPP(3rd Generation Partnership Project) LTE(Long Term Evolution) FDD(Frequency Division Duplexing) / TDD(Time Division Duplexing) dual mode system. In general, PSS(Primary Synchronization Signal) correlation based estimation method and CP(Cyclic Prefix) correlation based tracking loop are applied for coarse and fine frequency synchronization in 3GPP LTE OFDMA(Orthogonal Frequency Division Multiple Access) system, respectively. However, the conventional coarse frequency synchronization method has performance degradation caused by fading channel and squaring loss. Also, the conventional fine frequency synchronization method cannot guarantee stable operation in TDD mode because of signal power difference between uplink and downlink subframe. Therefore, in this paper, we propose enhanced coarse and fine frequency synchronization methods which can estimate more accurately in multi-path fading channel and high speed channel environments and has stable operation for TDD frame structure, respectively. By computer simulation, we show that the proposed methods outperform the conventional methods, and verify that the proposed frequency synchronization method can guarantee stable operation in 3GPP LTE FDD/TDD dual mode downlink receiver.

Quality Metric with Video Characteristics on Scalable Video Coding (영상 특성을 고려한 스케일러블 비디오 기반 품질 메트릭)

  • Yoo, Ha-Na;Kim, Cheon-Seog;Lee, Ho-Jun;Jin, Sung-Ho;Ro, Yong-Man
    • Journal of Broadcast Engineering
    • /
    • v.13 no.2
    • /
    • pp.179-187
    • /
    • 2008
  • In this paper, we proposed the qualify metric based on SVC and the subjective quality. The proposed quality metric is for a general purpose. It means we can use it for any video sequences regardless of its temporal and spatial characteristics. The Quality of Service(QoS) is one of the important issues in heterogeneous environment which has diverse restrictions such as limited network bandwidth and limited display resolution. Scalable Video Coding(SVC) is the efficient video coding skill in heterogeneous environment. Because SVC can be adapted to various quality bitstreams using three scalabilities(spatial, temporal, and SNR) from one bitstream which has full scalability. To maximize the QoS in this environment, we should consider the subjective quality which is the viewer response. And also we should consider temporal and spatial characteristics of video sequence because the subjective quality is affected by temporal and spatial characteristics of video sequence. To verify the efficiency of the proposed method, we perform subjective assessments. The experimental results show that the proposed method has high correlation with subjective quality. The proposed method can be a decision tool of SVC birstream extraction.

A Study on the Development of SSB Modem (디지털 SSB 모뎀 개발에 관한 연구)

  • Kim, Jeong-Nyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1852-1857
    • /
    • 2007
  • The SSB modem performs the modulation process which converts the digital voltage level to the audible frequency band signal and the demodulation process which converts reversely the audible frequency signal to the digital voltage level. The modulator and the demodulator are implemented with a single DSP chip. Because of the SSB specific character, the distortion occurs when the frequency is changed. This distortion has no effect on voice communication but it has an significant effect on data communication. In other words, it is impossible to send data stream with adjacent 2 periods. Therefore, in case of using 2-tone FSK, it is needed to send at least 3 periods to transmit 1 bit. Therefore we implemented the modem using modified phase-delay shift keying to transmit 1 tone signal for high speed transmission. In the 1200[bps] mode, it generates 0, $187{\mu}s$, delay time at 1.3kHz symbol frequency, and in the 2400[bps] mode, 0, $70{\mu}s\;130{\mu}s\;200{\mu}s$, delay time at 1.5kHz symbol frequency. Finally, in the maximum 3600[bps] mode, it generates 0, $100{\mu}s\;160{\mu}s\;250{\mu}s$ 2.0kHz symbol frequency. The measured results of the implemented SSB modem shows a good transfer functional characteristic by spectrum analyzer, almost same bandwidth in pass band and 20dB higher SNR comparing the emu FACTOR and American CLOVER and in the experimental transmitting test, we verified the transmitted data is received correctly in platform.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.