• 제목/요약/키워드: heating value variation

검색결과 70건 처리시간 0.029초

Diurnal Variation of Atomospheric Pollutant Concentrations Affected by Development of Windstorms along the Lee Side of Coastal Mountain Area

  • Choi, Hyo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제24권1호
    • /
    • pp.29-45
    • /
    • 1996
  • Before (March 26, 1994) or after the occurrence of a downslope windstorm (March 29), the NO, $NO_2$, and $SO_2$ at the ground level of Kangnung city were monitored with high concentrations in the afternoon, due to a large amount of gases emitted from combustion of motor vehicle and heating apparatus, especially near 1600-1800 LST and 2000-2100 LST, but at night, they had low concentrations, resulting from small consumptions of vehicle and heating fuels. When both moderate westerly synoptic-scale winds flow over Mt. Taegwallyang and easterly meso-scale sea breeze during the day, atmospheric pollutants should be trapped by two different wind systems, resulting in higher concentration at Kangnung city in the afternoon. At night, the association of westerly synoptic wind and land breeze can produce relatively strong winds and the dissipation by the winds cause these low concentrations to lower and lower, as nightime goes on. From March 27 through 28, an enforced localized windstorm could be produced along the lee side of the mountain near Kangnung, generating westerly internal gravity waves with hydraulic jump motions. Sea breeze toward inland appartantly confines to the bottom of the eastern side of the mountain, due to the interruption of eastward violent internal gravity waves. As the windstorm moves down toward the ground, an encountering point of two opposite winds approaches Kangnung, and a great amount of NO and $NO_2$ were removed by the strong surface winds. Thus, their maximum concentrations are found to be near 18 and 20 LST, 17 and 21 LST. In the nighttime, the more developed storm should produce very strong surface winds and the NO and $NO_2$ could be easily dissipated into other place. The $SO_2$ concentration had no maximum value, that is, almost constant one all day long, due to its removal by the strong surface winds. Especially, the CO concentrations were slightly lower during the strom period than both before or after the strom, but they were nearly constant without much changes during the during the daytime and nighttime.

  • PDF

온수배관에 의한 온실 내부의 온도변화 (Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse)

  • 윤용철;신익수;배승범;김현태;최진식;서원명
    • 농업생명과학연구
    • /
    • 제46권2호
    • /
    • pp.179-190
    • /
    • 2012
  • 본 연구는 유가상승에 따른 온실의 경영비 절감과 적설지역의 적설재해를 경감시키기 위하여 온수배관을 이용한 난방효과 및 온실곡부의 온도 상승효과를 구명하고자 수행되었다. 전체적으로 실험구의 온도가 대비구 보다 약 $2.0{\sim}6.0^{\circ}C$정도 높게 나타났다. 천창부직포를 개방한 경우, 최저온도가 약 $3.0{\sim}12.0^{\circ}C$범위로 나타나 적극적인 난방을 하게 되면 적설피해도 어느 정도 예방할 수 있을 것으로 판단되었다. 온실 내부의 높이별 온도 차이는 미미한 것으로 나타났다. 재배작물에 따른 온실의 최대난방부하는 각각 약 $37,000kcal{\cdot}h^{-1}$$41,700kcal{\cdot}h^{-1}$정도이었다. 실험기간동안 최저 외기온 $-11.9{\sim}4.0^{\circ}C$ 범위에서 설정온도별 발열량은 95,000~322,000 kcal 정도로서 시간당 $6,050{\sim}20,900kcal{\cdot}h^{-1}$정도의 범위에 있었고, 최대난방부하와 비교하면 약 15~56%정도의 난방에너지를 공급할 수 있을 것으로 나타났다. 그리고 실험기간동안 전체 발열량과 소비전력량은 각각 2,629,025 kcal 및 677.3 kWh이었다. 화석연료인 경유로 난방 할 경우, 실험기간동안 소요되는 소비량은 291L 정도이었고, 비용은 331,700 won인 것으로 나타났다. 전력사용에 대한 총비용은 24,400 won정도로서 경유 소비 비용의 7.5%정도로 나타났다. 또한 전체 소비전력량을 에너지로 환산하면 약 582,200 kcal이고, 이 에너지는 전체 발열량의 약 22%에 불과하였다.

자갈식 축열조의 축열특성에 관한 연구 (A study on the Thermal Characteristics of a Thermal Storage Tank for using Gravels)

  • 박정원;박봉규;안상규
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.81-87
    • /
    • 1992
  • 본 연구의 목적은 건물의 냉난방에 이용되는 현열이용형 축열조의 축열 특성을 규명하는데 있었다. 실험에 사용된 축열재는 자갈이었으며 일정한 온도조건하에서 축열재 사이를 통과하는 유체의 유동속도와 자갈의 크기별로 실험을 하였다. 자갈의 크기와 유속을 변화시켜 축열량과 축열효율을 실험적으로 구한 결과 축열재의 충진율이 72.5%이고 유속이 0.14m/s일 때가 최단시간 내에 최대축열량에 도달하였으며, 축열효율도 가장 높았다.

  • PDF

Vuilleumier 사이클로 작동되는 열구동 냉동기의 예비설계조건 (Preliminary Design Conditions for a Thermally Actuated Refrigerator Based on the Vuilleumier Cycle)

  • 유호선;강병하
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2358-2367
    • /
    • 1992
  • 본 연구에서는 그 기초단계로서 작동유체의 실제상태변화에 근접하면서 간편 한 근사적인 단열해석법을 적용하여 VM사이클의 구체적인 예비설계조건을 제시하고자 한다.

열복사에 의한 수직연료면의 점화현상 해석 (Ignition of a Vertically Positioned Fuel Plate by Thermal Radiation)

  • 한조영;백승욱
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2353-2364
    • /
    • 1995
  • The ignition phenomena of a solid fuel plate of polymethyl-methacrylate(PMMA), which is vertically positioned and exposed to a thermal radiation source, is numerically studied here. A two-dimensional transient model includes such various aspects as thermal decomposition of PMMA, gas phase radiation absorption, gas phase chemical reaction and air entrainment by natural convection. Whereas the previous studies considers the problem approximately in a one-dimensional form by neglecting the natural convection, the present model takes account of the two-dimensional effect of radiation and air entrainment. The inert heating of the solid fuel is also taken into consideration. Radiative heat transfer is incorporated by th Discrete Ordinates Method(DOM) with the absorption coefficient evaluated using gas species concentration. The thermal history of the solid fuel plate shows a good agreement compared with experimental results. Despite of induced natural convective flow that induces heat loss from the fuel surface, the locally absorbed radiant energy, which is converted to the internal energy, is found to play an important role in the onset of gas phase ignition. The ignition is considered to occur when the rate of variation of gas phase reaction rate reaches its maximum value. Once the ignition takes place, the flame propagates downward.

분리형 히트파이프의 저발열량 연료가스 예열시스템에 대한 적용연구 (Application of a Large Scale Heat Pipe System to Preheating the Fuel Gas of Low Heating Value)

  • 박흥수;유갑종;이진호;이용국
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1085-1097
    • /
    • 1999
  • A separate heat pipe system capacity of 3,700kW has been developed and applied to preheating the blast furnace gas for recovery of the waste heat from boiler. The system is designed to preheat the blast furnace gas up to $126^{\circ}C$ by using tho boiler exhaust gas of which temperature is $180^{\circ}C{\sim}220^{\circ}C$. The arrangement of the fin tubes as well as the shape of the fin has been carefully determined to minimize the fouling problems. The heat pipe system was found to be stable in circulation of the working fluid and the range of the temperature variation of the preheated blast furnace gas was within $10^{\circ}C$. It was proved through a long-term test that the selected tube arrangement and the shape of the fins are proper to prevent the fouling problems and that the pay-back period of the system Is within one year.

연료 조성 및 스파크 플러그 위치 변경으로 인한 가스 엔진의 성능에 관한 연구 (Study on the Performance of an SI Gas Engine by Fuel Composition and Spark Plug Variation)

  • 김용래
    • 한국가스학회지
    • /
    • 제18권6호
    • /
    • pp.21-26
    • /
    • 2014
  • 연료의 사용으로 인한 이산화탄소의 발생량을 줄일 수 있는 방법으로 바이오가스 또는 매립가스와 같은 신재생 가스 연료를 사용하는 방법이 도움이 될 수 있다. 그러나 다량의 불활성가스가 포함되어 있기 때문에 저발열량 및 연료 조성의 불균일함은 신재생 가스 연료를 발전용 엔진에 적용하는 경우, 엔진 성능에 큰 영향을 미칠 수 있기 때문에 이에 대한 연구가 필요하다. 본 연구에서는 신재생가스연료에 불활성가스가 엔진 연소가 불안정한 정도로 많이 포함된 경우에 수소 연료를 첨가함으로써 연소 안정성을 개선할 수 있음을 확인하고, 엔진의 열효율 및 배기 특성과 같은 성능 변화에 대하여 살펴보았다. 또한 같은 조건에서 엔진 효율 및 배기 성능을 향상시키기 위한 방안으로 길이가 긴 전극을 갖는 스파크 플러그를 적용하여 효과가 있음을 확인하였다.

쌀겨 분진의 훈소 위험성에 관한 연구 (A Study on the Smoldering hazard of Rice bran dust.)

  • 이창우;김정환;현성호
    • 한국화재소방학회논문지
    • /
    • 제13권2호
    • /
    • pp.12-17
    • /
    • 1999
  • 쌀겨분진의 훈소위험성을 조사하기 위하여 자연발화 시험기를 이용하여 시료의 입도분포 및 시료량에 따른 쌀겨분진의 연소특성을 시간에 따른 온도의 변화로 측정하였다. 또한 자연발화 시험기 내부의 공기흐름에 따른 연소특성을 조사하고자 자연발화시험기 내부를 송풍과 무풍 상태로 하여 연소상태를 관찰하였다. 연구결과, 쌀겨분진의 연소에 따른 발열개시온도는 약 18$0^{\circ}C$~219$^{\circ}C$ 범위에 있으며, 시료입도에 따른 훈소 개시온도의 차이가 크지는 않으나, 시료량이 증가함에 따라 훈소 개시온도가 다소 낮아지고 있었다. 또한 시료의 양이 증가할수록 훈소시 시료 내부의 온도차가 크게 발생하는 것을 볼 수 있으며, 시료의 입도가 미세할수록 훈소시 시료 내부의 온도차는 다소 증가하는 형태를 보이고 있다. 한편, 시험기 내부가 송풍상태일 때 보다 무풍상태로 실험하였을 경우 훈소 개시시간이 다소 빨라지고 있으며, 발열온도도 크게 나타났다.

  • PDF

상용채소의 부위에 따른 환원형 Ascorbic acid량과 조리방법에 따른 C량의 변화 (Quantity of Ascorbic Acid in the Parts of Vegetable and Its variation by Cooking Method)

  • 강신주
    • 대한가정학회지
    • /
    • 제4권1호
    • /
    • pp.589-594
    • /
    • 1963
  • Ascorbic acid has a strong power to reduce other materials, so by using this reducing power we can analise many materials quantitatively. Dihydro-ascorbic acid is quantitatively changed into ascorbic acid under a certain condition, if reduced by hydrogen-sulfide. Dihydro-ascorbic acid also has physiolosical effect, but less effect than ascorbic acid. The effect of dihydro-ascorbic acid is regarded as a half of that of ascorbic acid. Among the analytical methods applying this theory the method using 2.6 dichlorophenol indophenol what called the method of Indophenol is used most widely; so does Hydrazine-method. But comparing these two methods the former shows a little higher rate in analytical value. Vegetable are vital sources for vitamin C. According to the report of the commitee of FAO Korean branch the amount of daily per head average intake of vitamin C is about 70mg in raw materials. Since vitamin C is easily affected by heating or oxidation in Cooking the loss is not a little. Consequntly it is regarded that the actual amount of intake will be much less than basic amount. It is therefore very important to find out that how much percent of the loss there will be in case of cooking, in order to dicide the actual amount of in take as proper nutrition for a person. Therefore this paper intended to give some help in setting a standard amount of V.C intake, by measuring the change of the V.C amount using the general cooking method and by measuring amount of V.C contained in the part of vegetable, used in Korea abundantly.

  • PDF

Time-Varying Seismogenic Coulomb Electric Fields as a Probable Source for Pre-Earthquake Variation in the Ionospheric F2-Layer

  • Kim, Vitaly P.;Hegai, Valery V.;Liu, Jann Yenq;Ryu, Kwangsun;Chung, Jong-Kyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권4호
    • /
    • pp.251-256
    • /
    • 2017
  • The electric coupling between the lithosphere and the ionosphere is examined. The electric field is considered as a timevarying irregular vertical Coulomb field presumably produced on the Earth's surface before an earthquake within its epicentral zone by some micro-processes in the lithosphere. It is shown that the Fourier component of this electric field with a frequency of 500 Hz and a horizontal scale-size of 100 km produces in the nighttime ionosphere of high and middle latitudes a transverse electric field with a magnitude of ~20 mV/m if the peak value of the amplitude of this Fourier component is just 30 V/m. The time-varying vertical Coulomb field with a frequency of 500 Hz penetrates from the ground into the ionosphere by a factor of ${\sim}7{\times}10^5$ more efficient than a time independent vertical electrostatic field of the same scale size. The transverse electric field with amplitude of 20 mV/m will cause perturbations in the nighttime F region electron density through heating the F region plasma resulting in a reduction of the downward plasma flux from the protonosphere and an excitation of acoustic gravity waves.