• 제목/요약/키워드: heating space

검색결과 675건 처리시간 0.026초

농촌 마을회관의 노인 복지서비스 공간으로의 활용 방안 - 평면과 이용행태 분석을 중심으로 - (Conceptual Directions of Village Community Center into a Rural Elderly's Welfare Service Space in Chonbuk Province)

  • 최병숙;박선희;오찬옥;홍찬선;임상봉
    • 한국농촌건축학회논문집
    • /
    • 제8권2호
    • /
    • pp.80-93
    • /
    • 2006
  • This purpose was to explore various directions of elderly service welfare space in village community center. Data were collected 3 types that floor plans of village community centers from 24 villages, interview data of these centers use and needs from 24 aged leaders or 96 elderly. The results were as followed: 1) The floor plans of more than 50% was type IV that was composed a basic spaces(entrance, living room, two rooms, kitchen), a toilet space, a heating system space and a storage space. This type was a current basis of the rural village community centers for elderlies. 2) Elderlies used the centers at winter or out of agricultural season, and visited these to pass the time and to promote friendship among them. 3) Also they went these to take a meal together and to save down personal heating expenses. Their needs for centers were a temporary share dwelling space at winter, a maintain social relationship throughout a health, a education and a side work activity, supplying health or sports facilities, and setting up toilet space. Therefore the current centers were needed to add functions of a temporary share dwelling, a energy saving heat system and a social promoting relationship, and so these could be represented to a elderly welfare service center in rural villages.

  • PDF

Study on Comparison of Atmospheric and Vacuum Environment of Thermally-Induced Vibration Using Vacuum Chamber

  • Kong, Chang-Duk;Park, Hyun-Bum;Lee, Ha-Seaung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.26-30
    • /
    • 2010
  • The present paper studies the thermally-induced vibration phenomenon of the flexible space boom structure. In order to simulate the thermally-induced vibration phenomenon of the flexible thin boom structure of the spacecraft with the attached tip mass in space, the thermally-induced vibration including thermal flutter is experimentally investigated at various thermal environments using a heating lamp in vacuum chamber. In this experimental study, fluctuating characteristics, natural frequency and thermal strains of the thermally-induced vibration are parametrically investigated at various thermal environment conditions. Finally the thermally-induced vibration of the flexible boom structure of the orbiting earth satellite in solar radiation environment from the earth eclipse region including umbra and penumbra is simulated using the power control of the heating lamp in the vacuum chamber.

스마트 스페이스 구축을 위한 지능형 디지털 분산 제어 시스템 개발 (Intelligent Digital Decentralized Control System for Smart Space)

  • 주영훈
    • 제어로봇시스템학회논문지
    • /
    • 제12궈1호
    • /
    • pp.54-59
    • /
    • 2006
  • The smart space is composed of the wire and/or wireless network, multi-sensor-based environment, and many various controllers. For the smart space, this paper presents a new design method of multirate digital decentralized controller using the intelligent digital redesign technique. In specific, the proposed method is based on the delta-operator and the multirate sampling and takes the form of the LMIs. To shows the feasibility of the suggested method, the computer simulations for Heating, ventilating, and ai. conditioning (HVAC) system are provided.

수산소 혼합가스를 이용한 선상가열 특성 (The Characteristics of Line Heating Using Hydrox Gas)

  • 김홍건;곽이구
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.407-411
    • /
    • 2011
  • The technology of line heating has evolved in various methods. Among them, fossil fuels like ethylene gas and LPG(Liquid Petroleum Gas) are widely used due to their simple utility. In the meantime, the technology implementing high frequency for line heating has also been developed continually, but its manufacturing technology or application includes lots of problems by now. One of the main characteristics of line heating using conventional technolob'Y is the quenching effect followed by heating process. On the other hand, hydrox gas which is mixed by hydrogen and oxygen is a prominent candidate for an application without above shortcomings. Especially, it is found that line heating using hydrox gas is tremendously effective taking low cost as well as low noise. In this paper, a small cell with high efficiency which can minimize installing space is developed to deal with the problem installing in narrow place. Experiments to prove the validation, efficiency and effectiveness is carried out by characterizing in the line heating of steel. It is found that the energy saving of using hydrox gas for line heating is significant and that the deviation performance is reduced by 78~89%. Furthermore, the noise is also reduced as amount of 18.3% though the heating time is not too different.

"Dust, Ice, and Gas In Time" (DIGIT) Herschel observations of GSS30-IRS1

  • Je, Hyerin;Lee, Jeong-Eun
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.66.2-66.2
    • /
    • 2013
  • As part of the DIGIT key program, we observed GSS30-IRS1, a Class I object located in Ophiuchus (d=125 pc), with Herschel-PACS. More than 70 lines were detected in 50-200 micron band including CO, OH, H2O, and [OI]. All lines, except for [OI], were detected only at the central spaxel of $9.4^{{\prime}{\prime}}{\times}9.4^{{\prime}{\prime}}$ while the [OI] emission is extended along the NE-SW direction. One interesting feature in GSS30-IRS1 is that the continuum is extended beyond PSF, unlike line emission. It suggests that the external heating is important in GSS30-IRS1. For detail analysis of line fluxes, we apply the non-LTE LVG model, RADEX as well as simple rotational diagrams. We also use the Monte Carlo radiative transfer package, RADMC-3D to understand the heating mechanism of dust grains around GSS30-IRS1. We will discuss about heating and cooling processes associated with GSS30-IRS1.

  • PDF

고등학교 기숙사 주거시설에 대한 사용자 만족도 (Users' Satisfaction on the Dormitory of High School in Jeonju City)

  • 안진숙;최병숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.202-207
    • /
    • 2006
  • This study was to find out users' satisfaction on the dormitory high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows : 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 3.23, and the space utility and the space size of functional factor and the heating/ventilation of technical factor were highly effected their satisfaction.

  • PDF

2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析) (Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System)

  • 김영득;민만기;이상혁;김원갑
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

운량에 따른 태양열 시스템의 성능 분석에 관한 연구 (Study on the Performance Analysis of Solar Heating System with Cloud Cover)

  • 김원석;표종현;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1215-1219
    • /
    • 2009
  • In this study, the performance of solar assisted hybrid heat pump system with cloud cover were analyzed by using experimental method in spring season. It was consisted of concentric evacuated tube solar collector, heat medium tank, heat storage tank, heat pump, and so on. As a result, the solar radiation should be maintained over $4.1\;MJ/m^2$ in order to operate solar heating system for heating. Solar heat of collector wasn't affected by ambient temperature, but cloud cover has a big effect to collector efficiency. In addition, the collector efficiency is about 50-60%, and solar fraction is 40% for this system.

  • PDF

온돌난방주택의 난방방식별 열 특성에 관한 실험연구 (Experimental Study on the Thermal Characteristics in Ondol Heating Systems)

  • 윤정숙
    • 한국주거학회논문집
    • /
    • 제1권1호
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

온수 이용에 관한 열역학적 해석 (A thermodynamic analysis on the utilization of thermal water)

  • 이세균
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.97-104
    • /
    • 1987
  • 본 논문에서는 순수한 액체상태의 온수 단위 질량을 대상으로 동력발생에서부 터 열펌프 까지의 가능한 응용을 고려하여 온도에 따른 최적 사용방법과 최대성능 발 휘시의 용량산정을 통하여 온수의 최적능력을 확인하고자 한다. 단 본 연구의 결과 는 순수히 열역하적인 것으로 경제적 관점에서 본다면 다소 다른 견해가 있을 수 있겠 으나 열역학적 및 경제적 관점 사이의 관계 및 제2법칙의 역할의 중요성은 이미 여러 논문에서 충분히 거론된 것으로서 여기서 언급하지 않는다.