• Title/Summary/Keyword: heating space

Search Result 675, Processing Time 0.028 seconds

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

A study on the radiant heat exchange in living space (거주공간에서의 복선열교환에 관한 연구 -착의시의 착의부와 노출부의 열수수)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.2
    • /
    • pp.75-82
    • /
    • 1986
  • This study was measured experimentally the Configuration factor of the adult female with the purpose of explaning quantitatively the human body's radiant heat exchange in a small scale of a house. And it is a investigatio about human clothed body's heat resistance which have great influence on radiant heat exchange. The result of this study was diagrammatized the [Shape×Area Factor] for the sake of making it easy to calculate the quantity of the actual human body's radiant heat exchange, and designed a diagram to make it easy to find the value of the human clothed body's heat resistance and clothing surface temperature. Thus, this research can be used as a basic resource for not only calculating wuantitatively radiant heat exchange of human clothed body and unclothed body in the radiant heating system of low temperature but also designing the thermal environment in a room.

  • PDF

Development of decision making index for balcony extension in apartment houses (로지스틱 회귀분석을 이용한 공동주택 발코니 확장)

  • Lee, Hye Lin;Park, Min Ha;Ko, Yong-Ho;Han, SeungWoo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.83-84
    • /
    • 2015
  • Remodeling of apartment houses has been increasing recently and residents have chosen to extend the balcony along with the legalization of balcony extension in apartment houses. Balcony extension provides residents more space, however, it has been investigated that balcony extension increases construction cost, heating and cooling cost and decreases sound insulation performance. Therefore, this study focuses on developing a decision making index for residents in remodeling required apartment houses. The suggested methodology involves surveying actual residents, survey analysis by AHP and decision model development using logistic regression analysis.

  • PDF

A Study on the Heat Transfer Enhancement by Trapezoid Rod in Impinging Jet System (충돌분류계에서 사다리형 로드를 이용한 열전달증진에 관한 연구)

  • Lim, T.S.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.565-571
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. In this study, trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters: (a) the space from rods to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). And this research compared the above with the experiment without trapezoid rods. As a result, heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. In this case, maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

  • PDF

Study on the Working Characteristics of Vaporizer for Super Low Temperature Liquefied Gas (초저온 액화천연가스용 기화기의 운전특성에 관한 연구)

  • Kong, T.W.;Yi, S.B.;Lee, S.C.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.99-105
    • /
    • 2005
  • LNG Vaporizers must be smaller, more efficient, and easier to operate and maintain. Recently, the vaporizers with greatly enhanced performance as compared to conventional type, have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has fixed ice. These characteristic has efficient down and total plant cost and installing space can be increase. On that reasons must be optimize through tube and pipes analysis and experiments with enhanced type in this study. In this study performance to the workong characteristics for air heating type vaporizer for super low temperature liquefied gas.

  • PDF

Thermal Comfort of the Floor Supply Air Conditioning System for Different Supply-return Locations during Cooling (급배기 위치에 따른 바닥급기 공조시스템의 냉방 열환경)

  • 김요셉;김영일;유호선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.476-485
    • /
    • 2000
  • This study numerically investigates thermal comfort in a space cooled by the floor-supply air conditioning system, in which three different supply-return locations, one floor supply-ceiling return and two floor supply-floor returns, are treated. A complementary experiment is peformed to validate the present numerical analysis, and the prediction agrees favorably with the measured data. In the numerical procedure, a simplified model mimicking the inlet flow through the diffuser is developed for efficient simulations. The calculated results show that the ceiling return type is far better in thermal comfort than the floor return ones within the extent of this study, which seems to be caused by effective vertical penetration of the supply air against natural convection. It is also revealed that the arrangement of port locations in the floor supply-floor return system has insignificant effect on the cooling performance. For selecting a proper system, other characteristics including the heating performance should be accounted for simultaneously with the present estimation.

  • PDF

Environmental Impact Assessment for Development Projects Considering Carbon Sink and Sequestration(II) - Focused on a Housing Redevelopment Project - (탄소흡수원을 고려한 개발사업 환경영향평가 방안(II) - 주택 재개발 사업을 중심으로 -)

  • Hwang, Sang Il;Park, Sun Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.79-87
    • /
    • 2011
  • In this study, we investigated the effect of carbon sequestration and sink on the environmental impact assessment of a housing redevelopment project. Through the case study, we found that the amount of carbon sequestration and sink increased with the increase of the area of park and green space and, furthermore, the amount of carbon emission decreased slightly with implementation of district heating and renewable energy. Therefore, it is necessary for its land use plan to be established to minimize the amount of net carbon emission, taking account of both the amount of present carbon emission and the amount of the future carbon sink, sequestration, and emission.

Freezing and Melting Phenomena of Urea-water Solution for Diesel Vehicle SCR System (디젤차량 SCR 시스템용 요소수용액의 동결과 해동 현상)

  • Choi, B.C.;Seo, C.K.;Myong, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2009
  • Urea-SCR system, the selective catalytic reduction using urea as reducing agent, is a powerful technique to reduce nitrogen oxides(NOx) emitted from diesel engines. However, a tank of urea(32.5 wt%)-water solution can be frozen in low ambient temperature levels of below $-11^{\circ}C$. The purpose of this study is to understand freezing and melting phenomena of the urea-water solution, and its can be applied to get the urea-water solution from frozen it within 5 minutes after cold start. Factors considered were the type of heater and the urea tank shape. From the results, it was found that melting volume of cartridge heater B during 5 minutes of heating period was 83ml when supplying electric power of 150W. Horizontal heater B, which was put in the narrow bottom space of the tank T1, had fast melting characteristics.

  • PDF

A Study on Spatial Design of Elementary School Based on Ecological Approach (생태적 개념을 도입한 초등학교 실내공간 디자인에 관한 연구)

  • 윤지영;송주은
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.118-126
    • /
    • 2004
  • This study started from the premise that the future elementary school should be designed based on ecological approach in order to restore the emotionality of children. This study aimed at providing a guideline for designing the interior of elementary schools based on ecological approach. Through literature review, the characteristics of ecological architecture and the regulations for green buildings were explored. Also 7 elementary schools which were evaluated as good school design through renowned books representing the ecological characteristics were chosen and analyzed. The results revealed that the school design included natural lighting by roof lighting, natural ventilation, greening, and use of natural materials. This study suggested three categories as a the guideline for the interior space of eco-school design; energy efficiency, greening and sustainability, which included natural lighting, natural ventilation, heating and cooling, planting, materials and water recycling.

The effect of magnetic field on a thermoelastic fiber-reinforced material under GN-III theory

  • Alzahrani, Faris S.;Abbas, Ibrahim A.
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.369-386
    • /
    • 2016
  • In this work, the two-dimensional generalized magneto-thermoelastic problem of a fiber-reinforced anisotropic material is investigated under Green and Naghdi theory of type III. The solution will be obtained for a certain model when the half space subjected to ramp-type heating and traction free surface. Laplace and exponential Fourier transform techniques are used to obtain the analytical solutions in the transformed domain by the eigenvalue approach. The inverses of Fourier transforms are obtained analytically. The results have been verified numerically and are represented graphically. Comparisons are made with the results predicted by the presence and absence of reinforcement and magnetic field.