• 제목/요약/키워드: heating method

검색결과 2,713건 처리시간 0.031초

가열조건에 따른 동부묵의 기호도 (Effect of Heating Conditions on Preference of Cowpea Mook)

  • 김성곤;이애랑
    • 한국식품영양과학회지
    • /
    • 제27권6호
    • /
    • pp.1100-1104
    • /
    • 1998
  • The preference test of cowpea mook(gel prepared with air-dried sediment of cowpea) indicated that the optimum concentration and heating temperature for mook-making were 8% at 95$^{\circ}C$ or 9% at 90$^{\circ}$and 95$^{\circ}C$ with continuous heating method(A), and 8% at 85$^{\circ}C$ or 7% at 9$0^{\circ}C$ with instantaneous heating method(B). Among the samples the mook made from 9% at 95$^{\circ}C$ with the method A was the most preferable. The degree of increase in hardness of mook prepared by the method B stored at 6$^{\circ}C$ for 8hr was much slower than that by the method A. the preference test of the mook stored at 6$^{\circ}C$ for 1 day revealed that the mook by the method A with 8%(95$^{\circ}C$) and by the method B with 7 and 8% (85$^{\circ}C$) were not significantly different.

  • PDF

공동주택 바닥복사 난방시스템의 GRNN 제어 적용에 관한 연구 (A Study on GRNN Control Strategies for Floor Radiant Heating System in Residential Apartments)

  • 송재엽;안병천
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.830-836
    • /
    • 2012
  • In this study, the effects of heating control methods on heating control performance and energy consumption in the floor radiant heating control system of residential apartments were research by computer simulation. A general regression neural network(GRNN) control method for reducing indoor temperature overshoot and saving energy in floor radiant heating system is suggested. The GRNN control method shows good responses in comparison with the conventional and outdoor reset control methods for improving indoor thermal environment and reducing energy consumption.

아파트 난방비 징수제도 개선에 관한 연구 (I) (Study on the System of Heating Cost Allocation of Apartments (I))

  • 박상동;박효순;우정선;유헌형;공성훈;유승광
    • 대한설비공학회지:설비저널
    • /
    • 제16권2호
    • /
    • pp.140-153
    • /
    • 1987
  • Main objective of this study is to provide heating cost allocation method according to the amount of heating energy consumption in apartments. Heating energy consumptions are calculated by DOE-2.1A program. As a result, heat loss ratio in Ondol heating system, heating cost coefficients of apartments and its using method is presented. Maximum heating cost coefficient rate is 2.63.

  • PDF

지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션 (Measurement and Simulation of Heating Energy for Apartments with District Heating)

  • 이은주;이두영;홍희기;김영균
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

실효온도차법에 의한 최대열부하 계산용 온습도에 관한 연구 (Design Temperature and Absolute Humidity for Peak Cooling and Heating Load Calculation with ETD Method)

  • 김두천;서진석
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.278-284
    • /
    • 1993
  • A simplified TAC method was developed for the selection of design temperature and absolute humidity for peak cooling and heating load calculation with ETD method. And the design data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the design data for summer and autumn cooling season were selected by the TAC 5.0% of July through August and TAC 5.0% of October, respectively. But the design data for winter heating season were selected by the conventional TAC 2.5% of the full winter season.

  • PDF

비자성 유도가영시스템을 위한 IGBT를 이용한 고속스위칭 구동에 관한 연구 (The Study on High-Frequency Switching Drive Method Using IGBT For Non-Magnetic Induction Heating System)

  • 김정태;권경안;정윤철;박병욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.24-26
    • /
    • 1998
  • A new high frequency switching drive method using IGBT is proposed for non-magnetic induction heating system. Using this method, the switching and conduction losses of the switching devices can be reduced. In addition, since IGBT cosl is lower than MOS-FET one, the system cosl can be remarkably pared down. The prototype induction heating system with 1.2㎾ power consumption is builted and tested to verify the operation of the proposed high frequency switching drive method.

  • PDF

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

발열구명동의 착용에 의한 인체의 체온변화에 관한 수치해석 (Numerical Analysis on Body Temperature Change with Heating Life Vest)

  • 김명준
    • 해양환경안전학회지
    • /
    • 제14권3호
    • /
    • pp.241-245
    • /
    • 2008
  • 본 논문은 해난사고에 의해 빈번하게 발생하는 저체온증으로 인한 인명손실을 최소화하기 위하여 개발된 발열구명동의의 열적특성을 수치해석을 통해 조사한 것으로, 계산에 이용된 주된 파라메터는 계절에 따른 수온, 구명동의의 발열량 및 발열시간이다. 이산화 및 차분방정식은 유한차분법을 이용하였으며, 컴퓨터를 이용한 계산을 위하여 매스캐드를 이용하여 프로그래밍을 작성하였다. 또한 본 논문은 서로 다른 물질들이 경계를 이루고 있는 복잡한 형태의 모델에 해당함으로 경계에 해당하는 부분의 열전도율은 열저항의 모델을 응용하여 인접한 셀들의 열전도값을 이용하여 계산하였다. 본 연구를 통하여 발열구명동의의 열발생으로 인체의 온도를 높게 유지할 수 있음을 알았고, 겨울철을 제외하고 저체온증의 우려가 없음을 알았다. 또한 해난사고시 생존율을 높일 수 있을 것으로 기대된다.

  • PDF

유전가열물질을 코팅한 활성탄소섬유의 휘발성 유기화합물 흡착 및 마이크로파 인가에 의한 탈착 연구 (A Study on Adsorption of Volatile Organic Compound by Activated Carbon Fiber Coated with Dielectric Heating Element and Desorption by Applying Microwave)

  • 김상국;장예림
    • 한국대기환경학회지
    • /
    • 제25권2호
    • /
    • pp.122-132
    • /
    • 2009
  • Adsorption of toluene by activated carbon fiber (ACF) coated with dielectric heating element and desorption by applying microwave were investigated. In order to prepare adsorbent so that VOC can be desorbed by microwave heating, fine dielectric heating element with nano size was coated on the surface of the ACF using hybrid binder. Eight adsorbents (ACF-DHE, Activated Carbon Fiber coated with Dielectric Heating Element) were prepared with different amount of dielectric heating element, kinds of hybrid binder, and solvent. In order to investigate adsorption characteristics, BET surface area, pore volume, and average pore size were measured for each adsorbent including ACF. Breakthrough experiments with toluene concentration, flow rate, bed length using fixed bed reactor were performed to investigate adsorbality of adsorbent, and results were compared with that of the ACF. Desorption reactor was constructed with modified microwave oven to investigate heating effect on ACF-DHE by applying microwave power. Each adsorbent saturated with toluene were put into desorption reactor. Composition of desorbed gas generated by applying controlled microwave power to reactor was measured. Up to now, hot air desorption method has been used. Experimental results showed that desorption method with new adsorbent prepared by coating dielectric heating element on ACF can be used for industrial application.

반용융 성형에서 강제 표면 냉각에 의한 유도 가열 방법에 관한 연구 (A Study on Induction Heating with Forced Surface Cooling in Semi-Solid Forming Process)

  • 박준홍;최영
    • 한국정밀공학회지
    • /
    • 제22권1호
    • /
    • pp.97-102
    • /
    • 2005
  • The procedure of semi-solid forming is composed of heating a billet, forming, compression holding and ejecting step. There are several methods to heat a billet during semi-solid forming process such as electric heating and induction heating. Usually in semi-solid forming process, induction heating has been adopted to achieve more uniform temperature of semi-solid material. Although induction heating is better method than any others, however, there is still difference of temperature between internal part and surface part of semi-solid material. Worse yet, in case of high liquid fraction of semi-solid material, liquid of the billet will flow down though solid of the billet still remains, which is very difficult to handle. In the present study, induction heating of semi-solid material with compulsive surface cooling has been performed to obtain uniform distribution of temperature. Distribution of temperature of the billets was measured and compared with that of conventional distribution of temperature. By this new induction heating method, not only temperature over the whole billet become uniform, but also control of temperature is possible.