• Title/Summary/Keyword: heating jang

Search Result 531, Processing Time 0.036 seconds

A Study on the Li5Fe5O8 Species Affecting the Microwave Heating Performance on the Ternary Li-Fe-Zn Material (3원계 금속산화물로 제조한 마이크로웨이브 발열소재상 Li5Fe5O8 종이 발열성능에 미치는 영향 연구)

  • Jang, Young Hee;Lee, Sang Moon;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.703-709
    • /
    • 2018
  • Dielectric heating materials were prepared through the thermal treatment for composites of Li and Zn type precursors that are major materials being responded to microwave under diversified conditions. The prepared heating material samples were analyzed by SEM and it was confirmed that $Li_5Fe_5O_8$ materials being formed on the surface was a major influencing factor for the heating performance. Heating materials improved the moisture removal in a sludge drying facility, for example, the moisture content of 25 v/v% sludge decreased to 15.22 v/v%. Accordingly, heating materials were confirmed to directly affect the performance and efficiency of the microwave drying process.

Inhibitory Effects of Some Treatments on Browning During Yam(Discorea batatas Decne) Tuber Processing (가공과정중(加工過程中) 마 괴근조직(塊根組織)의 갈변억제처리(褐變抑制處理) 효과(效果))

  • Kang, Dong-Kyoon;Kim, Sang-Kuk;Chung, Sang-Hwan;Lee, Seong-Phil;Choi, Boo-Sull
    • Korean Journal of Medicinal Crop Science
    • /
    • v.6 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • Browning index rised rapidly within 15 hrs to 83% of total browning in Jang - ma (Dioscorea batatas Decne) tissues at $40^{\circ}C$ while 37% in Dan - ma. Therefore, the degree of browning process of Jang - ma was faster than that of Dan - ma. Browning in Jang - ma was inhibited by treatments of NaCl which showed 48 and 39% inhibition, respectively, after 48 hrs of incubation. Also the treatment of $80^{\circ}C$ heating showed excellent inhibition within 24 hrs. In the case of Dan - ma, browning process was inhibited by treatments of 1 and 0.5M NaCl and $70^{\circ}C$ heating, which showed 43, 26 and 23% inhibition, respectively, after 48 hrs of incubation.

  • PDF

Realtime Simulation of Deformation due to Line Heating for Automatic Hull Forming System (곡가공 자동화 시스템을 위한 선상가열에 의한 변형의 실시간 시뮬레이션)

  • Dae-Eun Ko;Chang-Doo Jang;Seung-Il Seo;Hae-Woo Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.116-127
    • /
    • 1999
  • Line heating is a method widely used in forming ship hull surface. From the viewpoint of mechanics it is large deformation thermal elasto-plastic problem of arbitrary shaped plate. Many researches have been carried out to resolve this problem. Especially, Jang et al.[1] proposed a simplified thermal elasto-plastic analysis method to predict effectively the deformation of plate due to line heating. In this paper, we improved the method of Jang et al.[1] by considering tension yielding in temperature decreasing stage and verified with experimental results. FEA program using MITC4 degenerated shell element was made to deal with elastic large deformation problem. The newly proposed method can be used in the simulation and control of forming hull surface for higher productivity with simplicity and efficiency.

  • PDF

Simnlation of a Thermal Behavior in Solar Heating and Cooling System with respect to Demand Room Temperature (실내 설정온도에 따른 태양열 냉난방 시스템의 동적 거동 해석)

  • Jang, H.Y.;Lee, S.B.;Chung, K.T.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3446-3451
    • /
    • 2007
  • The thermal behavior of a building in response to heat input from an active solar space heating system is analysed to determine the effect of the variable storage tank temperature on the cycling rate, on and off temperature of a heating cycle and on the comfort characteristics of room air temperature. A computer simulation of the system behavior has been performed and verified by comparisons with various parameters. Especially, this study is focused on the effect of the system's performance when subjected to dynamic cooling loads. The heat input to the absorption system is provided by an array of solar collectors that coupled to a thermal storage tank.

  • PDF

LTPS produced by JIC (Joule-heating Induced Crystallization) for AMOLED TFT backplanes

  • Hong, Won-Eui;Lee, Seog-Young;Chung, Jang-Kyun;Lee, Joo-Yeol;Ro, Jae-Sang;Kim, Dong-Hyun;Park, Seung-Ho;Kim, Cheol-Su;Lee, Won-Pil;Kim, Hye-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.378-381
    • /
    • 2009
  • As a Joule-heat source, a conductive Mo layer was used to crystallize amorphous silicon for AMOLED backplanes. This Joule-heating induced crystallization (JIC) process could produce poly-Si having a grain size ranging from tens of nanometers to greater than several micrometers. Here, the blanket (single-shot whole-plane) crystallization could be achieved on the $2^{nd}$ and the $4^{th}$ generation glass substrate.

  • PDF

An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger (전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구)

  • Jang, Young-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.8
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

Paeparation and Properties of Epoxy Copolymers Containing Oxime-urethane Groups as Photobase Generators

  • Chae, Gyu Ho;Song, Hye Bong;Seon, Ho Yong;Jang, Ji Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.7
    • /
    • pp.690-696
    • /
    • 2000
  • Epoxy copolymers containing oxime urethane groups were prepared by the polymerization of glycidyl methacrylate and N-[5-(benzophenoneoximinocarbonylamino)pentanyl]maleimide (BOPM). Their physical properties were characterized by GPC, DSC and TGA analyses. Photochemical changes of the copolymers were studied by UV, IR spectroscopy, and contact angle measurements. A photoinduced cross-linking reaction in copolymer films was observed by measuring the insoluble fraction. Irradiation of the copolymers at 254 nm UV light leads to the formation of pendant amino groups by photodissociation of the oxime-urethane groups. Treatment of the amino groups with HCl resulted in the formation of ammonium salts, which changed the polymer surface to be hydrophilic. An insoluble fraction of the copolymers increased with irradiation time, heating time, and heating temperature. Cross-linking of the epoxy resin effectively catalyzed by the photogenerated pendant amines upon heating.

Pyrolysis Behavior of Pulverized Coal Particles at High Heating Rate (미분탄 입자의 고속가열 열분해거동 해석)

  • JANG, JIHOON;HAN, KARAM;YU, GEUN SIL;LIM, HYEON SOO;LEE, WOOK RYUN;PARK, HO YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.260-268
    • /
    • 2019
  • The pyrolysis characteristics of pulverized coal particle was numerically analyzed with the drop tube furnace. Based on the simulated gas flow field in the drop tube furnace, the particle velocity, temperature and volatile evolution were calculated with the fourth order Runge-Kutta method. The effects of changes in reactor wall temperature and particle diameter on the pyrolysis behavior of coal particle were investigated. The particle heating rate was very sensitive to the reactor wall temperature and particle size, that is, the higher wall temperature and the smaller particle size resulted in the higher heating rate and the consequent quicker volatile evolution.