• Title/Summary/Keyword: heating information

Search Result 524, Processing Time 0.034 seconds

A Baseline Study on Housing Cultures for Cross-Cultural Comparison between Korean- Australians and Australians(I) : An Analysis of Housing Cultures of Korean- Australian Families. (호주인과 호주 교민의 주거문화 비교를 위한 기초 연구(I) -호주 교민의 주생활 분석을 중심으로 -)

  • Lee Young-Shim;Lee Sang-Hae
    • Journal of Families and Better Life
    • /
    • v.23 no.2 s.74
    • /
    • pp.107-125
    • /
    • 2005
  • Each ethnic group has a different cultural background and has developed its own culture in the name of a tradition. The interaction between different cultures is ever increasing through the process of acculturation or culture contact The purpose of this study is to provide baseline information about domestic living of Korean immigrants in Australia and Australians for a larger cross-cultural study project. As the first step, the usage of domestic space and seating styles of 52 Korean households in Melbourne were analyzed. Ethnographic research was conducted, utilizing a questionnaire. The findings of this research are as follows: 1. The most popular type of Living-Dining-Kitchen arrangement was the one which the kitchen is separated from the living and dining area. The level of satisfaction was the highest when the living room, dining room, and kitchen were all separated. 2. A laundry room was indispensable for Koreans in Australia, and they wanted to dry laundry and do ironing in there. Most people were satisfied with the toilet separated from the bathroom A drain hole on the floor of the bathroom was not indispensable for most Korean-Australians. 3. Korean-Australians tend to engage in various activities in their individual rooms, and they estimated that the size of most rooms were small. They also wanted to renovate the house to expand the rooms. 4. The seating style of Korean-Australians was mostly chair-seating. Yet, they often made beds on the floor for guests, and made kimchi sitting on the floor. Also, when they were relaxing, they were using both chair-seating and floor-seating. 5. Korean-Australians were not very satisfied with the use of floor carpets because of the dust collected on the carpets, and the difficulty to clean. It may be related to their preferred floor seating style, as well. 6. Almost all Korean-Australians take off their shoes inside of the house for hygienic reasons. They had a shoes cabinet at the entrance inside of the house. 7. The most popular heating system was ducted heating. The level of satisfaction about this was moderate because hot air contains lots of dust and it makes rooms very dry. Many were using electric blankets and their desired heating system was Ondol (heated floor). 8. Korean-Australians thought that the living room was the most important place for the family, and believed it should be decorated well to entertain guests. They also pointed out that the lighting was not bright enough in general.

Characteristics and Fabrication of Micro Gas Sensor with Single Electrode (단일전극을 가진 마이크로 가스센서의 제작 및 특성)

  • Song, Kap-Duk;Bang, Yeung-Il;Lee, Sang-Mun;Lee, Yun-Su;Choi, Nak-Jin;Joo, Byung-Su;Seo, Moo-Gyo;Huh, Jeung-Soo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.350-357
    • /
    • 2002
  • Micro gas sensor with single electrode was proposed for improving stability and sensitivity. Generally, metal oxide gas sensors have two electrodes for heating and sensing. This fabricated new type sensor have only a single electrode by forming a sensing material onto heating electrode. Pt as a heating and sensing electrode was sputtered on glass substrate and a $SnO_2$ sensing material was thermally evaporated on Pt electrode. $SnO_2$ was patterned by lift-off process and then thermally oxidized in $O_2$ condition for 1 hr., $600^{\circ}C$. The size of fabricated sensor was $1.9{\times}2.1\;mm^2$. As a result of CO gas sensing characteristics, this sensor showed 100 mV change for 1,000 ppm and linearity for wide range($0{\sim}10,000\;ppm$) of gas concentrations. And the sensor shows a good recovery characteristics of 1% deviation compared to initial resistance.

Urinary PAH Metabolites as Biomarkers of Environmental PAHs Exposure (환경성 PAHs 노출과 생체지표 연구)

  • Lee, Kyoung-Ho;Li, Zhung-Min;Cho, Soo-Hun;Kwon, Ho-Jang;Kang, Dae-Hee
    • Toxicological Research
    • /
    • v.23 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The aim of the study was to see if there is any differences in urinary 1-hydroxypyrene glucuronide (1-OHPG) and 2-naphthol levels in children ($8{\sim}14$ years old) and their mothers ($30{\sim}46$ years old) living three cities in South Korea (Seoul, Incheon and Pohang) and three in China (Changchun, Datong and Kunming), where the levels of air pollution varies. The factors related with urinary biomarkers levels were also evaluated. The study subjects consisted of 118 Korean (60 children and 58 their mothers) and 120 Chinese (60 children and 60 their mothers). Urinary 1-OHPG was measured by synchronous fluorescence spectroscopy after immuno-affinity purification using monoclonal antibody 8E11 and urinary 2-naphthol concentrations were determined by HPLC with fluorescence detector. Information on recent consumption of diet containing high PAHs, environmental tobacco smoke (ETS), type of cooking and heating fuels, and other life-style characteristics were collected by self-administered questionnaire. The arithmetic mean of urinary 1-OHPG levels (n = 120, $mean{\pm}SD$, $6.77{\pm}7.96{\mu}mol/mol$ creatinine) in Chinese were 10 fold higher than those in Korean (n = 118, $0.62{\pm}0.61{\mu}mol/mol$ creatinine) (P < 0.01). Urinary 2-naphthol levels in Chinese (n = 119, $59.50{\pm}82.29{\mu}g/g$ creatinine) were significantly higher than those in Korean (n = 117, $25.09{\pm}46.56{\mu}g/g$ creatinine) (P < 0.01). Urinary 1-OHPG and 2-naphthol levels were significantly higher in children living the polluted cities in China (Datong and Chanchun, respectively). Multiple linear regression analysis indicated that living in factory area (vs. residential area) and use of coal stove as heating fuel were significant predictors for urinary 1-OHPG (overall model $R^2$= 0.46, n = 204). And ETS was predictor for urinary 2-naphthol levels in Korean ($R^2$ = 0.36, n = 46). These results indicated that urinary 1-OHPG and 2-naphthol levels were related with different ambient particulate air pollution, type of heating fuels and ETS.

A Experimental Study on the Evaluation of Deteriorated Concrete Member Exposed One Side at High Temperature (고온에 일면 노출된 콘크리트부재의 손상깊이 평가를 위한 실험적 연구)

  • Lee, Joong-Won;Choi, Kwang-Ho;Hong, Kap-Pyo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.431-438
    • /
    • 2006
  • The determination of the depth of deteriorated concrete is one of the main problems in the structural assessment of concrete structures that have been subjected to a fire. This information is particularly important in order to optimize the future operations of repair/strengthening, or in decision-making concerning a possible demolition. The purpose of this study is to propose evaluation technique of damaged depth of concrete exposed at high temperature. In order to evaluate damaged depth of core picked at member under fire, the 24 specimens have been made with variables of concrete strength(20 MPa, 40 MPa, 60 MPa) and heating exposure condition in 600 and 800 for 2 hours. Color change analysis and water absorption after heating have been measured and split tensile stress test was performed to ka the residual compressive strength against the depth of specimen. The results show that the deeper of the depth from heating face, water absorption ratio is smaller and residual stress ratio is larger and the color of heated face is changed to red color. Using this technique at damage evaluation of fired structure, We evaluate damaged depth of member under fire and determine the reasonable strengthening range.

A CMOS Readout Circuit for Uncooled Micro-Bolometer Arrays (비냉각 적외선 센서 어레이를 위한 CMOS 신호 검출회로)

  • 오태환;조영재;박희원;이승훈
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.1
    • /
    • pp.19-29
    • /
    • 2003
  • This paper proposes a CMOS readout circuit for uncooled micro-bolometer arrays adopting a four-point step calibration technique. The proposed readout circuit employing an 11b analog-to-digital converter (ADC), a 7b digital-to-analog converter (DAC), and an automatic gain control circuit (AGC) extracts minute infrared (IR) signals from the large output signals of uncooled micro-bolometer arrays including DC bias currents, inter-pixel process variations, and self-heating effects. Die area and Power consumption of the ADC are minimized with merged-capacitor switching (MCS) technique adopted. The current mirror with high linearity is proposed at the output stage of the DAC to calibrate inter-pixel process variations and self-heating effects. The prototype is fabricated on a double-poly double-metal 1.2 um CMOS process and the measured power consumption is 110 ㎽ from a 4.5 V supply. The measured differential nonlinearity (DNL) and integrat nonlinearity (INL) of the 11b ADC show $\pm$0.9 LSB and $\pm$1.8 LSB, while the DNL and INL of the 7b DAC show $\pm$0.1 LSB and $\pm$0.1 LSB.

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

Indepth Study of Numerical Heat Transfer and Fluid Flow for Energy Saving of Greenhouse (시설하우스 에너지 절감을 위한 열유동 수치 해석 심층 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Choi, Jun-Ho;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.466-471
    • /
    • 2007
  • The purpose of study is to obtain basic but important information for the operation of the greenhouse facility located in the suburb of town. Special emphasis is given on the aspect of energy saving method, which can be easilyapplicable in a practical sense. For this end numerical calculation has been made systematically in order to increase the energy efficiency by the evaluation of the temperature distribution in greenhouse. Major parameters considered are primarily the overall shape of greenhouse together with the various conditions of baffle installion inside greenhouse. Further, the performance of heating system is also carefully compared each other for a number of typical arrangements of heating duct. The performance of the computer program developed in this study is evaluated by the observation of the famous fluid trapping phenomenon occurred in staggered baffle condition in the enclosure of greenhouse. Based on the this study, a number of useful conclusions can be drawn, that is, the installation of baffles are quite effective in energy saving method with a minor modification of facility. Also, it is found that the change of the heating duct system can contribute significantly to the uniform temperature distribution in greenhouse. Further other findings obtained by numerical calculation were not only physically consistent and meaningful but also useful for the determination of optimum condition of practical operation of greenhouse.

A Comparative Study of Housing Culture of Korean Immigrants through Analysis of Living Arrangement in Australia and Canada (해외거주 한인의 주공간 사용 및 주생활 분석을 통해 본 주거문화의 비교 고찰 - 호주(Australia)와 캐나다(Canada)를 중심으로 -)

  • Lee, Young-Shim
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.1
    • /
    • pp.47-61
    • /
    • 2008
  • The purpose of this study is to provide information about domestic living of Korean immigrants in Australia and Canada who have the same cultural background for comparative study. For this, usage of domestic space and living style in housing of 52 Korean households in Melbourne of Australia and 32 Korean households in the region of Waterloo of Canada were analyzed. Ethnographic research with questionnaire were used. Results of the research were as follows. 1. Korean immigrants in each countries were living in houses which was built by company of Australia and Canada. 44.2% of Korean immigrants in Australia were using L+D K and 53.1% of Korean immigrants in Canada were using L D K. 2. Laundry was indispensable for Korean immigrants in both countries and they all wanted to use the laundry as a utility room which could dry, ironing and so on. 3. Drain hole on the floor of the bathroom was not indispensable for most Korean immigrants in both countries for hygienic reason. 4. Korean immigrants in both countries were ironing in master bedroom and they all wanted to separate it from there through renovation and extension and so on. 5. Korean immigrants in Canada were more active to use the formal lounge which has been planned as a traditional element of western house. 6. The seating style of Korean immigrants in both countries belong to chair-seating style mostly. But it was clear that they were making Kimchi with floor seating style in both countries. 7. A level of satisfaction about using carpet was not high for Korean immigrants in both countries cause of uneasiness to clean and it was considered to relate to the floor seating style of them. 8. Almost Korean immigrants were took off the shoes inside of the house and they had shoes cabinet beside the entrance or basement usually. 9. The most popular heating system was ducted heating in both countries. The level of satisfaction about this was different for Korean immigrants in Australia and Canada but most desirable heating system was Ondol for them in both countries commonly.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.