• 제목/요약/키워드: heating experiment

Search Result 868, Processing Time 0.024 seconds

Study on the Combustion Reactivity of Residual Oil as a New Fuel for Power Generation (발전용 신종액체 연료의 연소반응성 해석)

  • Park, Ho-Young;Seo, Sang-Il;Kim, Young-Joo;Kim, Tae-Hyung;Chung, Jae-Hwa;Lee, Sung-Ho;Ahn, Kwang-Ick;Jeong, Young-Gap
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.534-545
    • /
    • 2011
  • This paper describes the evaluation of kinetic parameters for pyrolysis and carbon char oxidation of residual oil. The non-isothermal pyrolysis of residual oil was carried out with TGA (Thermo-Gravimetric Analyzer) at heating rate of 2, 5, 10 and $20^{\circ}C/min$ up to $800^{\circ}C$ under N2 atmosphere. The first order and nth order pyrolysis models were used to fit the experimental data, and the nth order model was turned out to follow the experimental data more precisely than the first order model. For carbon char oxidation experiment, TGA and four heating rates used in pyrolysis experiment were also adapted. The kinetic parameters for the residual carbon char particle were obtained with three char oxidation model, that is, volume reaction, grain and random pore model. Among them, the random pore model described the char oxidation behaviour quite well, compared to other two models. The non-linear regression method was used to obtain kinetic parameters for both pyrolysis and carbon char oxidation of residual oil.

Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler (Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察))

  • Lim, Jong-Pil;Bae, Na-Young;Han, Kyung-Soo;Ahn, Taek-Won
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

TEM Study on the Growth Characteristics of Self-Assembled InAs/GaAs Quantum Dots

  • Kim, Hyung-Seok;Suh, Ju-Hyung;Park, Chan-Gyung;Lee, Sang-Jun;Noh, Sam-Gyu;Song, Jin-Dong;Park, Yong-Ju;Lee, Jung-Il
    • Applied Microscopy
    • /
    • v.36 no.spc1
    • /
    • pp.35-40
    • /
    • 2006
  • Self-assembled InAs/GaAs quantum dots (QDs) were grown by the atomic layer epitaxy (ALE) and molecular beam epitaxy (MBE) techniques, The structure and the thermal stability of QDs have been studied by high resolution electron microscopy with in-situ heating experiment capability, The ALE and MBE QDs were found to form a hemispherical structure with side facets in the early stage of growth, Upon capping by GaAs layer, however, the apex of QDs changed to a flat one. The ALE QDs have larger size and more regular shape than those of MBE QDs. The QDs collapse due to elevated temperature was observed directly in atomic scale, In situ heating experiment within TEM revealed that the uncapped QDs remained stable up to $580^{\circ}C$, However, at temperature above $600^{\circ}C$, the QDs collapsed due to the diffusion and evaporation of In and As from the QDs, The density of the QDs decreased abruptly by this collapse and most of them disappeared at above $600^{\circ}C$.

Variation of Indoor Air Temperature by using Hot Water Piping in Greenhouse (온수배관에 의한 온실 내부의 온도변화)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Bae, Seoung-Beom;Kim, Hyeon-Tae;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.179-190
    • /
    • 2012
  • This study was performed to obtain a heat saving effect and enhance the efficiency of a greenhouse by using a hot water piping in order to minimize the operating costs of a greenhouse as oil prices continue to rise. This method also reduces the likelihood of accidents caused by snowdrifts in regions with heavy snowfall. In general, the experimental plot was $2.0{\sim}6.0^{\circ}C$ higher than the control plot. When the skylight felt was opened, the minimum temperature was in the range of $3.0{\sim}12.0^{\circ}C$. Therefore, we judged that damage caused by snowdrifts may be prevented partly by active heating. The temperature difference inside of the greenhouse by height was insignificant. The maximum heating load of the greenhouse according to crop was respectively about $37,000kcal{\cdot}h^{-1}$ and $41,700kcal{\cdot}h^{-1}$. During the experiment, the heat value of each designed temperature in the range of the minimum ambient temperature $-11.9{\sim}4.0^{\circ}C$ was about 95,000~322,000 kcal and it was in the range of $6,050{\sim}20,900kcal{\cdot}h^{-1}$. If it is compared with the maximum heating load, it can be shown that about 15~56% of the heating energy can be supplied. The total heat value and the amount of power consumption were 2,629,025 kcal and 677.3 kWh respectively during the experiment. If it is heated with diesel, a fossil fuel, the consumption during the experiment was 291 L and the cost was 331,700won. Total cost of using electric power was about 24,400 won and it is shown that it is about 7.5% of the cost of diesel consumption. Also, if the total amount of power consumption is converted into energy, it is approximately 582,200 kcal and the energy was just about 22% of the total heat value.

Microclimate of Greenhouses Covered with Functional Film (기능성 연질필름 온실의 미기상)

  • Chun, Hee;Choi, Young-Jun;Choi, Young-Ha;Kim, Hark-Joo;Lee, Si-Young;Jeong, Du-Seok;Shin, Yong-Seub;Choi, Chung-Don
    • Journal of Bio-Environment Control
    • /
    • v.16 no.2
    • /
    • pp.96-100
    • /
    • 2007
  • There was no difference in total light transmissivity of covering materials. But the light transmittance of J-2 in greenhouse was by 78.25 which was higher than any other film. The high light transmittance of J-2 was come from low water condensation and dust attached in film surface. The ultraviolet light of J-3 was completely intercepted. The ultraviolet transmittance rate of others was from 62 to 76%. In no heating oriental melon cultivation, the air temperature in tunnel was 15 to $21^{\circ}C$ higher than outer, and the soil temperature in tunnel was 20 to $25^{\circ}C$ higher than outer. Air temperature and soil temperature of J-2 were higher than any other film.

Characterization of Grape Seed Oil

  • Kang, Han-Chul;Park, Won-Jong;Kim, Si-Dong;Park, Jong-Cheon
    • Applied Biological Chemistry
    • /
    • v.41 no.8
    • /
    • pp.578-582
    • /
    • 1998
  • Grape seed oil was characterized to assess the usefulness in the food industry. Among the various oils, the initial antioxidant activity was the highest for grape seed oil. Heating the oil at $180^{\sim}C$ for 20 min retained 86% of the initial activity. Grape seed and sesame oils showed a low peroxide value, about 2, implying a less oxidative reaction. The oxidation of grape seed oil was increased to a less extent by heat-treatment than other oils. Light exposure for 1 month resulted in a slight decrease in the antioxidant activity of grape seed oil, maintaining 96% of the initial activity. Other oils were all light-susceptible and the activities decreased significantly. The peroxide values of all the oils increased by light exposure, but the extent of oxidation was still the least for grape seed oil. The addition of grape seed oil to perilla oil was very effective, in that the peroxide value was 5-times decreased by 1 : 5 composition of grape seed oil versus perilla oil. These results indicate that grape seed oil can be used as a good cooking oil or an additive for other oils.

  • PDF

Parameter Design and Analysis for Aluminum Resistance Spot Welding

  • Cho, Yong-Joon;Li, Wei;Hu, S. Jack
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.102-108
    • /
    • 2002
  • Resistance spot welding of aluminum alloys is based upon Joule heating of the components by passing a large current in a short duration. Since aluminum alloys have the potential to replace steels fur automobile body assemblies, it is important to study the process robustness of aluminum spot welding process. In order to evaluate the effects of process parameters on the weld quality, major process variables and abnormal process conditions were selected and analyzed. A newly developed two-stage, sliding-level experiment was adopted fur effective parameter design and analysis. Suitable ranges of welding current and button diameters were obtained through the experiment. The effects of the factors and their levels on the variation of acceptable welding current were considered in terms of main effects. From the results, it is concluded that any abnormal process condition decreases the suitable current range in the weld lobe curve. Pareto analysis of variance was also introduced to estimate the significant factors on the signal-to-noise (S/N) ratio. Among the six factors studied, fit-up condition is found to be the most significant factor influencing the SM ratio. Using a Pareto diagram, the optimal condition is determined and the SM ratio is significantly improved using the optimal condition.

Safety Evaluation for Pressure Rice Cooker Oven using Experiment (실험을 이용한 전기보온압력밥솥 오븐의 안전도 평가)

  • Lee, Seung-Pyo;Koh, Byung-Kab;Ha, Sung-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1541-1547
    • /
    • 2008
  • Because of good taste and quick cooking, the induction heating type pressure rice cooker is widely used. Since pressure is applied to oven structure, it should be necessary to check the safety evaluation. In this paper, strain gauge experiment is performed in order to evaluate the oven's strain and its result is compared with that of structural analysis. And water test is performed to evaluate the oven's permanent deformation. The result is also compared with that of structural analysis. By using these experiments and analyses the safety evaluation method of the oven is suggested.

The Thermal Environmental Characteristics for Task-Ambient Air-Conditioning System in Heating Condition (Task-Ambient 공조시스템의 난방시 열환경 특성에 관한 실험적 연구)

  • 이정재;윤창오;정광섭;한화택;박영철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.115-121
    • /
    • 2001
  • Recently, the requirement of healthier and more comfortable environment makes the zoning domain more details. However, it has limitation to satisfy the thermal comfort of an individual because of the effect of the heat generation from the OA machine and partitions in indoor room. In this paper, we certify the validity of task-ambient air-conditioning system that has been developed as a new concept of personal air-conditioning system, and specify design strategies for more efficient task-ambient air-conditioning system with a specification guided by indoor environmental characteristics analyzed through experiment data. In this experiment, we changed the temperature and the quantity of air-flow in task domain to understand characteristic behavior of the thermal environment and investigate the possibility of energy saving. The experiment result is that the environment of the task area depends on the condition of supply air, and though the airflow of the low temperature is supplied with the ambient area, the personal environment and the efficiency of energy saving are improved by controlling the temperature and the quantity of the air shot around the task domain.

  • PDF

NEW WEIGHTING COEFFICIENTS FOR CALCULATING MEAN SKIN TEMPERATURE IN RELATION TO THE POSTURE WITH CONSIDERATION TO HEAT CONDUCTION (열전도를 고려한 각 자세에 따른 평균 피부온의 산출)

  • Lee, Ju-Youn;MIYAMOTO, Seiichi;ISODA, Norio
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.63-74
    • /
    • 2000
  • This paper is to clarify a thermal physiological index that can account for the effects of local thermal environment. For this purpose two young female subjects exposing themselves to the above while sitting on a chair, sitting on the floor and lying on the floor were measured. These three representative postures accompanied the different contact surface areas, thereby the heat conduction rate between the floor and subject was quantitatively measured for each posture. It made the present study deal with the effect of heat conduction concerning the modified mean skin temperature and finally propose new weighting coefficients for the mean skin temperature calculation based on the Hardy & DuBois' formulas. In order to verify the proposed model, the experiment was carried out using a floor heating system. The comparison between the experimental result and prediction revealed that the proposed model should be about 10% more accurate than the conventional one in the case of lying on the floor which the heat conduction effect becomes important.

  • PDF