• Title/Summary/Keyword: heating elements

Search Result 264, Processing Time 0.035 seconds

SIMS Investigation of Black Cr Solar Selective Coatings (Black Cr 태양 선택흡수막의 SIMS 연구)

  • Lee, Kil-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.39-44
    • /
    • 2014
  • The elemental composition of electro-deposited black Cr solar selective coatings before and after heating in air by using secondary ion mass spectrometry (SIMS) was investigated for optical property analysis. In addition, black Cr selective coating exposed by solar radiation for 5 months was compared with heated sample. SIMS investigation shows that $OH^+$ bearing ions were related to a near surface region of CrOH and CrO compound. The optical degradation of this coating after heating at $500^{\circ}C$ reveals that diffusion of the Cu and Ni elements in substrate material, the chemical interactions adjacent to the interface, and the interface width broadening.

A study on the comfort thermal environment by the Draft in floor panel heating system (바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구)

  • KyungHeeLee
    • Journal of the Korean housing association
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

Characterization of Inorganic Chemicals in Total Suspended Particulates and a Source Apportionment by Chemical Mass Balance Model (대기 분진의 무기 화학적 조성 분석과 Chemical Mass Balance에 의한 오염원 기여도 산출)

  • Seo, Young-Hwa;Koo, Ja-Kong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.112-120
    • /
    • 1992
  • Twenty four metal, nonmetal elements and 4 major anions in total suspended particulates (TSP) collected at two sites in Daejon city from october to december in 1991 by a Hi-vol sampler were thoroughly analyzed by Inductively Coupled Plasma/ Atomic Emission Spectrometry (ICP/AES) and Ion Chromatography (IC). These analyzed data were used to perform a receptor modeling using the Chemical Mass Balance (CMB) for the source apportionment of TSP sample. Approximately 60% TSP weight in industrial complex area was influenced by potential industrial sources and 25% was by heating fuels and automobile emissions, whereas a half of TSP in residential area was influenced by surrounding environment and more than 35% of TSP was influenced by heating fuels. The CMB model provided source apportionment results reasonably and scientifically with a minor limitation.

  • PDF

The Study on Activity Star Problem and Optimum Construction Method Through the Defect Case of Zero Energy House in the Existing Building (기축건물의 제로에너지 하우스 하자 사례를 통한 공종별 문제점 및 최적구축 방안에 관한 연구)

  • Kim, Sun-Geun;Kwon, Soon-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.262-270
    • /
    • 2015
  • In this paper existing buildings, not a new buildings and house for living people not just a displaying and a viewing, created by the imagine effect or virtual simulation was applied various Active and Passive elements. After constructing zero-energy houses, through default case happened during operation period it is described problems and solutions about field part, work classification, installation by Location part, and Installation equipment part. Since then, to take advantage of this thesis, it's the purpose of this paper using as the baseline data for building a zero-energy house in another similar case.

Relations Between the Nocturnal Inversion Layer and Some Meteorological Elements in the Basin (분지내의 야간 접지역전층 변화와 관련된 기상요소에 대한 연구)

  • 진병화;황수진
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.369-374
    • /
    • 1998
  • Meteorological measurements were carried out in the basin of Cheong-Kwan located Yang-San near Pusan city, from Oct. 30 to Nov. 1, 1988. According to the measured data, we vended the close relationship between the variation of nocturnal Inversion layer and the meteorological elements. The nocturnal intrersion layer by radiative cooling in this site extends up to 130 meters or so. And the nocturnal jet ap- pears just above or at the top of the inversion layer, and the stronger of the prevailing wind blows, and the lower of the jet level appears. Some meteorological features such as heating, cooling etc., began to change in or in the slightly higher level of the inversion layer, when they are formed, reinforced and disappeared. And the it In the basin preserves its character because It Is not affected by local scale air flow.

  • PDF

A Human Engineering Study of Clothing in an Environmental Aspect (I) - Based on the Skin Temperature after Physical Exercise of Human Body - (환경요소면으로 본 의복의 인간공학적 연구 (I) - 인체동작후의 피부온 변화를 중심으로 -)

  • 이전숙
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.2
    • /
    • pp.65-71
    • /
    • 1982
  • Comfort concept of heating and cooling between body and environment is modified by the clothing. So were can say the clothing is one of the environment. To maintain“pleasantness”, clothing must have the elements of comfort and function. This study carried out for the 1st step to describe the relation between clothing and the human body I aspect to the emvironmental elements of temperature and working part of the body. Observations of skin temperature were taken on young adults female subjects in training wear and the skin temperature was measured onto 9 points of the body while taking part in two physical exercise, with Rawing machine and Bicycle ergometer. The results obtained are as follows; 1. The skin temperature after physical exercise is lower than that after repose. 2. After physical exercise of the lower part of the body, the skin temperature is less than that after physical exercise of the upper part of the body. 3. After physical exercise of the upper part of the body, skin temperature of the lower part of the body rises a little, and vice versa.

  • PDF

Fuzzy-Neuro Controller for Control of Air-Conditioning System

  • Lee, Sang-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1995
  • A practical application of a fuzzy-neuro controller is described for an air-conditioning system. Air-handing units are being widely used for improving the performance of central air-conditioning systems. The fuzzy-neuro control system has two controlled variables, temperature and humidity and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical contorl, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy-neuro control system is described for controlling air-conditioning systems efficiently and economically. Simulation results confirmed that the fuzzy neuro control system is effective for this multivariable system.

  • PDF

The Design of Efficient Fuzzy Logic Control System for Air-Conditioner (에어콘의 효과적인 퍼지 제어 시스템의 설계)

  • Kim, Il;Lee, Sang-Bae;Lee, Cheol-Yeong
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.4
    • /
    • pp.147-154
    • /
    • 1994
  • A practical application of a fuzzy control system is described for an air-conditioning system. Air-hadling units are being widely used for improving the performance of central air-conditioning systems. The fuzzy control system has two controlled variables, temperature and humidity, and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical control, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy control system was described for controlling air-conditioning systems efficiently and economically.

  • PDF

Optical components assembly by AIO bonding method (AIO 에 의한 Glass 광학부품 Bonding)

  • Potapov, S.;Ku, Janam;Yoon, Eungyeoul;Chang, Donghoon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.254-255
    • /
    • 2002
  • Optical elements such as small glass lenses or optical fibers can be permanently bonded to substrates using Al inter-layer by applying Pressure and heating. As an example aspherical lens was bonded on a silicon V-groove. The bonding has high shear strength and good thermal cycling stability.

  • PDF

Microstructure properties of internal tin processed Nb3Sn superconducting wires with pre-heating condition (내부확산법에 의한 Nb3Sn 초전도 선재의 예비 열처리 조건에 따른 미세조직 변화)

  • 하동우;오상수;하홍수;이남진;류강식;한일용;이준석
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.14-17
    • /
    • 1999
  • Four designed $Nb_{3}$Sn superconductors have been fabricated in order to investigate the effect of pre-heat treatment for internal tin process. 3 types of sub-elements and 2 types of Sn reservers were fabricated. Diffusion of Sn is better in the strand divided Sn equally than in the strand had one large Sn reserver during pre heat-treatment.

  • PDF