• Title/Summary/Keyword: heating correction

Search Result 48, Processing Time 0.023 seconds

Investigation of Heat Transfer in Microchannel with One-Side Heating Condition Using Numerical Analysis (수치 해석을 이용한 단일 마이크로채널의 단면 가열 조건의 열전달 특성에 관한 연구)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.986-993
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method far high density electronic devices. The cross-sectional shape of MEMS based microchannel heat sink is limited to triangular, trapezoidal, and rectangular due to their fabrication method. And heat is added to one side surface of heat source. Therefore, those specific conditions make some complexity of heat transfer in microchannel heat sink. Though many previous research of conjugate heat transfer in microchannel was conducted, most of them did not consider heat loss. In this study, numerical investigation of conjugate heat transfer in rectangular microchannel was conducted. The method of heat loss evaluation was verified numerically. Heat distribution was different for each wall of rectangular microchannel due to thermal conductivity and distance from heat source. However, the ratio of heat from each channel wall was correlated. Therefore, the effective area correction factor could be proposed to evaluate accurate heat flux in one side heating condition.

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Active-clamp Class-E High Frequency Resonant Inverter with Single-st (단일 전력단으로 구성된 Active-clamp E급 고주파 공진 인버터)

  • Kang, Jin-Wook;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Sim, Kwang-Yeal;Le, Bong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1193-1195
    • /
    • 2002
  • This paper presents Active-clamp Class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated Active-c class-E circuit to boost converter with the funct power factor correction. Boost converter is opera positive and negative half cycle respectively at frequency(60Hz), operating in Discontinuous Con Mode(DCM) of boost converter performs high p factor. By adding active-clamp circuit in Cl inverter, main switch of inverter part is operat only ZVS(Zero Voltage Switch), but also reduce switching voltage stress of main switch. Simulation result using Psim4.1 show that the p prove the validity of theoretical analysis. This proposed inverter will be able to be pract used as a power supply in various fields are ind heating applications, DC-DC converter etc.

  • PDF

A Study On Sing1e-Stage Active-Clamp Type High Frequency Resonant Inverter (단일 전력단 능동 클램프형 고주파 공전 인버터에 관한 연구)

  • 강진욱;원재선;김동희;조규판;김경식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.287-291
    • /
    • 2002
  • This paper presents active-clamp class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated active-clamp class-E circuit to boost converter with the function of power factor correction. Boost converter is operated in positive and negative half cycle respectively at line frequency(60Hz), Such a operating in discontinuous conduction mode(DCM) of boost converter performs high power factor. By adding active-clamp circuit in class-E inverter, main switch of inverter part is operated not only ZVS(Zero Voltage Switch) but also reduced the switching voltage stress of main switch. This paper shows that simulation result using Psim 4.1 prove the validity of theoretical analysis. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

A Measurement of restraint force during the heating and cooling cycle of the welding process (박판 용접시 온도변화에 따른 구속력 측정)

  • 고준빈;이영호
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.94-100
    • /
    • 2001
  • Distortion is a potential problem with all welded fabrication and should be caused dimensional changes and mismatch of joints during welding fabrication. Correction unacceptable weld distortion is extremely costly and in some case impossible. The aim of the present work is to verify the variation of the compressive force, tensile force and distortion during plastic deformation under Tungsten-inert-gas(TIG) welding, on type 304 stainless steel. Experimental results show that possibili-ty if measuring deformation during welding and good correlation was found between analytical and experimental result ad finite element methods have been used to model temperature analysis.

  • PDF

An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses (공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구)

  • 김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

LANDFILL STABILIZATION WITH LANDFILL MINING AND THERMAL TREATMENT PROCESS

  • Gust, Micheal A.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.12a
    • /
    • pp.97-101
    • /
    • 1996
  • Municipal and sanitary landfills can pose environmental problems due to leachate, landfill gas md unstable geotechnical properties. Most governmental bodies delay the correction of landfill problems or landfill replacement until a crises stage is reached. The replacement of a landfill is often made difficult due to costly regulatory controls, public opposition to siting and the high cost of closure for the previous landfill unit. Solutions to extending landfill life and capacity Involve waste minimization by recycling, refuse compaction and waste-to-energy incineration. Incineration can reduce the volume of refuse by 50-95%. The largest installed bases of municipal waste Incinerators are located in Japan and the U.S. The volume of waste contained in a landfill can be estimated by load count tabulations, weight-and-volume measurements or a material balance analysis based on the trash profile of user categories. for an existing landfill, core samples may be collected and analyzed for use in a material balance analysis. Newly generated refuse contains approximately 50% of the heating value of coal. However, landfill properties vary significantly due to the waste profile of the contributors and biodegradation due to time and weathering. The volume of the Nanji-do landfill

  • PDF

INNOVATIVE INDUCTION-HEATED HIGH-TEMPERATURE STEAMER USING VOLTAGE-FED HIGH-FREQUENCY RESONANT INVERTER

  • Guo, Bin;Nakamizo, Tetsuo;Nishida, Katsumi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.586-591
    • /
    • 1998
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid heating appliance using voltage-fed series capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state and dynamic state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance developed for hot water producer and superheated steamer.

  • PDF

Research Study on Seoul Region School Nutritionists' Perception of Potentially Hazardous Foods and Execution Conditions of Managing CCP Control Standard of the HACCP System - Focusing on CCP 3~CCP 7 - (서울지역 학교 영양(교)사의 PHF에 대한 인식 및 CCP 관리기준 수행실태 조사 - HACCP 시스템 CCP 3~CCP 7을 중심으로 -)

  • Lee, Ae-Rang
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.26 no.6
    • /
    • pp.517-530
    • /
    • 2016
  • This research was conducted on Seoul region elementary, middle, and high school nutritionists to analyze execution conditions of HACCP control standards, focusing on PHF and CCP 3~CCP 7, in order to determine more efficient methods for school meals' sanitation system settlement. All surveys were distributed and collected via email. A total of 305 survey papers were collected, and 300 school results were analyzed. The following percentage of nutritionists perceived the following foods as potentially hazardous foods(PHF): raw or cooked animal foods (94.7%), blossomed seed products (93.7%), packed pickled radish (36.7%), unopened mayonnaise (30.2%), and unopened snails & corn cans 54.8%. Exactly 51.2% of nutritionists believed that foods were properly supplied via CCP 3's food quality standard. Exactly 33.9% of nutritionists answered that they had never corrected the digital thermometer since there were no issues with the CCP 4's digital thermometer correction frequency level. As for CCP 5's chroline disinfection of green vegetables, 57.1% of nutritionists answered that vegetables were slightly softened while 36.2% said there were no changes at all. According to the nutritionists, the most difficult execution level of CCP levels (excluding CCP 3, CCP 4) was CCP 7 (37.1%), CCP 6 (16.4%), and CCP 2 (16.4%). For the above results, proper training/education must be enforced so that nutritionists can have a clear notion of the PHF. A solution must be developed enhancing the execution of CCP 4's digital thermometer correction frequency level. For CP 5's chroline disinfection of green vegetables, food characteristics must be considered to suggest an appropriate number and method of cleansing. Furthermore, cooking employees are needed that properly use and manage cooling & heating equipments to maintain heated foods above $57^{\circ}C$ under the CCP 7 standard.

The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module (부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.183-190
    • /
    • 2004
  • This paper proposes a methodology to solve problems upon the circuit design applied to inductor load by applying a circuit to improve power factor with is partial switching PFC module to the power supply system for cooling/heating inverter air conditioner and by designing an input power section in compliance with IEC555-2 on the basis of better input power factor and minimized harmonic components of current. On the other hand, this paper suggested how to control the increase of output voltage along with tぉw current waves and partial switching PFC circuit as well, which can provide the output as twice as input voltage This study applied a method to control the compressors of air conditioner by means of increased the voltage applicable to compressor motor by lowering switching number conclusively, it could solve questions about efficiency, economics, electronic noise and so forth. and so that the reasonable voltage for running moor could be set up along with lower power consumption of air conditioner than estimated It was demonstrated that total sum of energy efficiency to operate system was increased to the extent of valid level. And all this merits and appropriateness was proved by computer simulation and experience.