• Title/Summary/Keyword: heating correction

Search Result 48, Processing Time 0.02 seconds

Consideration of Temperature and Slip Correction for Photothermal Spectrometry

  • Lee, Jeonghoon
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.86-90
    • /
    • 2015
  • Temperature was considered to estimate the minimum detectable absorption coefficient of aerosol particles from photothermal spectroscopy. Light energy absorbed by subsequent emission from the aerosol results in the heating of the aerosol sample and consequently causes a temperature change as well as changes in thermodynamic parameters of the sample. This thermal effect is the basis of photothermal spectroscopy. Photothermal spectroscopy has several types of techniques depending on how the photothermal effects are detected. Photothermal interferometry traces the photothermal effect, refractive index, using an interferometer. Photoacoustic spectroscopy detects the photothermal effect, sound wave, using a microphone. In this study, it is suggested that the detection limit for photothermal spectroscopy can be influenced by the introduction of a slip correction factor when the light absorption is determined in a high temperature environment. The minimum detectable absorption coefficient depends on the density, the specific heat and the temperature, which are thermodynamic properties. Without considering the slip correction, when the temperature of the environment is 400 K, the minimum detectable absorption coefficient for photothermal interferometry increases approximately 0.3% compared to the case of 300 K. The minimum detectable absorption coefficient for photoacoustic spectroscopy decreases only 0.2% compared to the case of 300 K. Photothermal interferometry differs only 0.5% point from photoacoustic spectroscopy. Thus, it is believed that photothermal interferometry is reliably comparable to photoacoustic spectroscopy under 400 K.

3D simulation of Heat transfer in MEMS-based microchannel (MEMS 로 제작된 마이크로 채널에서의 3 차원 열전달 해석)

  • Choi, Chi-Woong;Huh, Cheol;Kim, Dong-Eok;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1870-1875
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method for high heat flux source. Contrary to conventional circular channel, MEMS based microchannel had rectangular or trapezoidal cross-sectional shape. In our study, we conducted three dimensional conjugate heat transfer calculation for rectangular shape microchannel. First, we simulated that channel was completely drained with known heating power. As a result we obtained calibration line, which indicates heat loss was function of temperature. Second, we simulated single phase heat transfer with various mass flux, 100-400 $kg/m^2s$. In conclusion, the single phase test verified that the present heat loss evaluation method is applicable to micro scale heat transfer devices. Heat fluxes from each side wall shows difference due to non-uniform heating. However those ratios were correlated with supplied total heat. Finally, we proposed effective area correction factor to evaluate appropriate heat flux.

  • PDF

A Study on Hazard Analysis and Critical Control Points(HACCP) in School Lunch by Analyzing Food Cooking Processes (초등학교급식 식단에 대한 조리공정별 HACCP에 관한 연구)

  • Bin, Sung-Oh;Kim, Moon-Ju
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.8 no.2
    • /
    • pp.79-95
    • /
    • 2007
  • A study was conducted in order to develope HACCP model in school lunch in Korea. Results: 1. Of 22 menus 4(18%) were non heating processes (#1), 2(9%) were food handling by using hands (#2), and 16(73%) were heating processes (#3). Of 279 menus 36(12.9%) belong to process #1, 8(2.9%) to process #2, and 235(84%) to process #3. 2. The critical control points for process #1 were contamination by hands of food handlers, and unsanitary food preparation habits of food handlers. Those for process #2 were improper heating temperature, contaminations by food handlers' hands, and unsanitary food handling habits, and cross contamination by unclean utensils and equipment. 3. Management criteria for the CCPs were conditions of food storage, refrigeration, freezing, food cooking temperature, personal hygiene, washing and sanitization of utensils and equipment. 4. Monitoring criteria for CCPs were observation, temperature checking, inspection of utensils and equipment, and practice of good personal hygiene. 5. Corrective actions were refusal of unsafe products, correction of improper temperature, proper cleaning and sanitization, and proper reheating time and temperature.

  • PDF

High Power Factor Dual Half Bridge Series Resonant Inverter for an Induction Heating Appliance with Multiple Loads (다부하를 갖는 유도가열기기를 위한 고역률 이중 하프브릿지 직렬공진 인버터)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.307-314
    • /
    • 1998
  • A novel high power factor Dual Half Bridge Series Resonant Inverter (DHB-SRI) for an induction heating appliance with multiple loads is proposed to remove the interferential acoustic noise caused by the difference between operating frequencies of adjacent loads. The circuit enables independent full power range control of two induction heating elements by one inverter circuit and has minimum switching losses due to the zero voltage switching characteristic. According to the mode analysis, I will explain the operation of the proposed circuit. To evaluate the required cooling capacity, loss analysis is performed through deriving some loss equations. In order to obtain the power factor correction capability and to lessen the system size, suitable design guides are given. Using the designed values, the proto-type circuit with 2.8kW power consumption for each induction heating element is built and tested to verify the operation of the proposed circuit.

  • PDF

A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes (항공관제용 정전류조정(CCR) 인버터 시스템의 개발)

  • Shon, Jin-Geun;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

A Numerical Study of the Air Quality Inside Automobiles According to the HVAC System Operating Conditions (HVAC 작동특성에 따른 자동차 실내 공기질 평가에 관한 수치해석적 연구)

  • Yoon, Seonghyun;Seo, Jinwon;Choi, Yunho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.299-309
    • /
    • 2014
  • When using an automotive heating, ventilation, and air conditioning (HVAC) system, we can obtain fresh outside air while maintaining the interior vehicle temperature. In this study, a correction equation considering experimental data for automotive indoor air leakage is defined to simulate the ratio of fresh air to recirculated air in the automobile cabin. With this correction equation, numerical results are compared with experimental data and validated. The $CO_2$ concentration in the automotive cabin is evaluated by considering various boarding conditions and mass flow rates of the HVAC system. The $CO_2$ concentration model derived in this study is expected to be used to control the effective air conditioning and become a basic research tool for automotive air quality control system development.

Development of Enhanced Interleaved PFC Boost Converter typed 650V Intelligent Power Module for up to 10kW HVAC Systems (10kW급 HVAC 시스템을 위한 Enhanced Interleaved PFC Boost 컨버터 형태의 650V IPM 개발)

  • Lee, Kihyun;Hong, Seunghyun;Kim, Taehyun;Jeong, Jinyong;Kwon, Taesung
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.536-538
    • /
    • 2018
  • This paper introduces an enhanced interleaved (IL) PFC (Power Factor Correction) boost converter typed 650V Intelligent Power Module (IPM), which is fully optimized hybrid IGBT converter modules; Silicon (Si) IGBT and Silicon Carbide (SiC) diode, for up to 10kW HVAC (Heating, Ventilation, and Air Conditioning) systems. It utilizes newly developed $4^{th}$ Generation Field Stop (FS) trench IGBTs, $EXTREMEFAST^{TM}$ anti-paralleled diodes, SiC Junction Barrier Schottky (JBS) diodes, Bridge rectifiers, Multi-function LVIC, and Built-in thermistor provide good reliable characteristics for the entire system. This module also takes technical advantage of DBC (Direct Bonded Copper) substrate for the better thermal performance. It is shown that the Si IGBT/SiC diode hybrid IL PFC module can achieve excellent EMI performance and greatly enhance the power handling capability or switching frequency of various applications compared to the Si IGBT/Diode. This paper provides an overall description of the newly developed 650V/50A Hybrid SiC IL PFC IPM product.

  • PDF

A study on the correction of the connection part of the underground facility 3D model and the correction of irregularities (지하시설물 3차원 모델 연결부 보정 및 요철보정에 관한 연구)

  • Kim, Sung Su;Han, Kyu Won;Heo, Sung Seo;Han, Sang Hoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.429-435
    • /
    • 2021
  • The integrated underground space map shows the underground facility(water supply, sewage, gas, electric power, communication, heating), underground structures (subway, underpass, underground walkway, underground parking lot, underground shopping mall, common ward), ground(drilling, coffin, geology) refers to a map constructed so that a total of 15 types of underground information can be checked at a glance on a three-dimensional basis. The purpose of this study is to develop a technology to correct the problem of curved surface processing and the unevenness of underground facility pipelines that occur in converting 2D underground facility data into 3D-based underground space integrated map(3D underground facility model). do it with. To this end, we first investigated and reviewed the domestic and foreign status of technologies that generate data on underground facilities based on three dimensions, and developed a surface correction algorithm and an unevenness correction algorithm to solve practical problems. Algorithms to verify the developed algorithm This applied correction program was developed. Based on the above process, the three-dimensional model of the underground facility could be produced identically to reality. This study is judged to have significance as a basic study to improve the utilization of the underground spatial integration map.

Zero Voltage Switching Boost H-Bridge AC Power Converter for Induction Heating Cooker

  • Kwon, Soon-Kurl;Saha, Bishwajit
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.19-27
    • /
    • 2007
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit incorporating boost H-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switch mode equivalent circuits and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft-switching(ZVS) operation ranges, and the power dissipation as compared with those of the conventional type high frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation(PWM) and pulse density modulation(PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

The Voltage-fed High Frequency Resonant Inverter Using Induction Heated Dry Steam Generator

  • Kim, Chil-Ryong;Lee, Jong-Kurl;Jung, Sang-Hwa;Mun, Sang-Pil;Kim, Sang-Don;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.415-418
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid beating appliance using voltage-fed type scries capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance for hot water producer and superheated steamer. The promising cost effective inverter-fed boiler appliances for electromagnetic induction-heated type fluid-heating in the pipeline systems are proposed for induction-heated boiler, super heat steamer, high temperature water producer, hot gas producer and metal catalyst heating for exhaust gas cleaning in engine, which are more suitable and acceptable for industrial, chemical, and consumer energy utilization for household and business from a practical point of view.

  • PDF